Sponsored Content
Full Discussion: Truss output interpretation
Top Forums UNIX for Advanced & Expert Users Truss output interpretation Post 302921508 by jim mcnamara on Friday 17th of October 2014 02:37:59 PM
Old 10-17-2014
Code:
From the read man page:

     When attempting to read from a regular file  with  mandatory
     file/record locking set (see chmod(2)), and there is a write
     lock owned by another process on the segment of the file  to
     be read:

         o    If O_NDELAY or O_NONBLOCK is set, read() returns -1
              and sets errno to EAGAIN.

pollsys then waits until the file can be read. The only possible cause is described above. This is POSIX compliant semantics for the read call. pollsys is a Solaris-ism (a system call entry point) for poll() and select(), I believe. Don Cragun would know definitely.
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

truss

I'm a DBA so no abuse please! I've for 5 Oracle Forms processes that are spinning and am trying to find out if they're doing anything: Running HPUX 11.11 CPU TTY PID USERNAME PRI NI SIZE RES STATE TIME %WCPU %CPU COMMAND 9 ? 2735 oracle 241 20 24228K 16668K run 2607:29 84.92... (2 Replies)
Discussion started by: fraze
2 Replies

2. UNIX for Advanced & Expert Users

truss output

Hi, We keep getting hanging Oracle process for our ETL. The dba's asked me to do o truss. All I see is pages and pages of the following,:cool: pollsys(0xFFFFFFFF7FFF38C8, 1, 0xFFFFFFFF7FFF3800, 0x00000000) = 0 pollsys(0xFFFFFFFF7FFF38C8, 1, 0xFFFFFFFF7FFF3800, 0x00000000) = 0... (0 Replies)
Discussion started by: happyadm
0 Replies

3. Shell Programming and Scripting

how to use truss?

Hi all, while trying to debug and figure out why a lofiadm command was not working on my script, i came across a cmd called "truss" all i know about it is that it executes the specified command and produces a trace of the system calls it performs, the signals it receives, and the machine faults... (5 Replies)
Discussion started by: wrapster
5 Replies

4. Shell Programming and Scripting

truss output

Hi I have to get redirect the truss ouput to file. I am doing truss -p 12121 >> output.txt But it still displays on the screen adn output.txt is empty Can some help how to do this? Thanks in advance Ammu (1 Reply)
Discussion started by: ammu
1 Replies

5. Shell Programming and Scripting

need help with truss !

i have to gather some info about a process and redirect it to a1.txt file. For this i m using truss command truss -po a1.txt $PID_Detail where $PID_Detail= 1482944 3362976 -------------------------------------------------------------------------- Below the script: #!/bin/ksh for i... (6 Replies)
Discussion started by: ali560045
6 Replies

6. AIX

lspath output interpretation

On my VIo I see the following for my disks: $ lspath | grep hdisk6 Enabled hdisk6 fscsi0 200600a0b82193f7,4000000000000 Enabled hdisk6 fscsi0 200700a0b82193f7,4000000000000 Enabled hdisk6 fscsi2 200600a0b82193f8,4000000000000 Failed hdisk6 fscsi2 200700a0b82193f8,4000000000000 $ lspath |... (8 Replies)
Discussion started by: petervg
8 Replies

7. AIX

Truss output

Hello, I'm using AIX 5.3.12.5 and trying to understand truss output. I'm running a job with real time of 16 minutes but only 4 minutes of CPU time. I'm trying to understand what the process is doing. I'm getting a lot of kread, kpread, kwrite, kpwrite... localhost:~ x$ grep... (1 Reply)
Discussion started by: Kovacs
1 Replies

8. UNIX for Dummies Questions & Answers

Truss output

Hi, I want to trace a background java program which runs in infinite loop. I have used truss command for this. But the program terminated after some hours with below truss output: Received signal #1, SIGHUP, in lwp_cond_wait() /1: siginfo: SIG#0 Please let me know what... (0 Replies)
Discussion started by: Hara Prasad
0 Replies

9. UNIX for Advanced & Expert Users

Truss output

Hi, I want to trace a background java program which runs in infinite loop. I have used truss command for this. But the program terminated after some hours with below truss output: Received signal #1, SIGHUP, in lwp_cond_wait() /1: siginfo: SIG#0 Please let me know what... (5 Replies)
Discussion started by: Hara Prasad
5 Replies

10. UNIX for Advanced & Expert Users

unable to understand the output of TRUSS command

Hi, I am trying to set ulimit for soft stack unlimited, but this is not taking effect, after tracing the ulimit -a unlimited command, the below output was generated, which i am unable to comprehend. Could any one help me with this? prcbap1-r10prod: truss -d ulimit -s unlimited Tue Dec 30... (2 Replies)
Discussion started by: NasirAbbasi
2 Replies
ppmtosixel(1)                                                 General Commands Manual                                                ppmtosixel(1)

NAME
ppmtosixel - convert a portable pixmap into DEC sixel format SYNOPSIS
ppmtosixel [-raw] [-margin] [ppmfile] DESCRIPTION
Reads a portable pixmap as input. Produces sixel commands (SIX) as output. The output is formatted for color printing, e.g. for a DEC LJ250 color inkjet printer. If RGB values from the PPM file do not have maxval=100, the RGB values are rescaled. A printer control header and a color assignment table begin the SIX file. Image data is written in a compressed format by default. A printer control footer ends the image file. OPTIONS
-raw If specified, each pixel will be explicitly described in the image file. If -raw is not specified, output will default to com- pressed format in which identical adjacent pixels are replaced by "repeat pixel" commands. A raw file is often an order of magni- tude larger than a compressed file and prints much slower. -margin If -margin is not specified, the image will be start at the left margin (of the window, paper, or whatever). If -margin is speci- fied, a 1.5 inch left margin will offset the image. PRINTING
Generally, sixel files must reach the printer unfiltered. Use the lpr -x option or cat filename > /dev/tty0?. BUGS
Upon rescaling, truncation of the least significant bits of RGB values may result in poor color conversion. If the original PPM maxval was greater than 100, rescaling also reduces the image depth. While the actual RGB values from the ppm file are more or less retained, the color palette of the LJ250 may not match the colors on your screen. This seems to be a printer limitation. SEE ALSO
ppm(5) AUTHOR
Copyright (C) 1991 by Rick Vinci. 26 April 1991 ppmtosixel(1)
All times are GMT -4. The time now is 04:09 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy