11-14-2013
Format unit requires destructive mode???
It is a series 700. I believe it is a 742.
9 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
I just updated sendmail to the newest version and got into this trouble. Somehow only can root can use sendmail while the other users will simply get "SMTP went away" when using pine or
"can not chdir(/var/spool/mqueue/): Permission denied
Program mode requires special privileges, e.g., root... (1 Reply)
Discussion started by: Micz
1 Replies
2. SuSE
Hi All,
I used to have my suse linux(VM) server in graphic mode but not anymore since morning. I cant rolback since i loose somuch work. Any idea how to it back to normal. Thanks (6 Replies)
Discussion started by: s_linux
6 Replies
3. Shell Programming and Scripting
How should i write a script so that the script will destroy(delete) itself once it completes execution.
Thanks? (7 Replies)
Discussion started by: proactiveaditya
7 Replies
4. UNIX for Advanced & Expert Users
Hi All,
Can please let me know what is the difference between the single line mode and multi line mode in regular expresions?
Thanks,
Chidhambaram B (3 Replies)
Discussion started by: chidhu.anu
3 Replies
5. Virtualization and Cloud Computing
Hello Unix Community:
My task to figure out how to add a 20G volume to an existing EBS Array (RAID0) at AWS.
I haven't been told that growing the existing volumes isn't an option, or adding another larger volume to the existing array is the way to go. The client's existing data-store is... (0 Replies)
Discussion started by: Habitual
0 Replies
6. HP-UX
Hi,
On load average graph, unit is 100m, 200m, 300...800m.
I don't understand what it means.
Thx for helping (3 Replies)
Discussion started by: Michenux
3 Replies
7. Cybersecurity
Hi I'm trying to hack a web server as part of an assignment and have gotten it to exec commands but I cannot pass commands arguments as the program splits up space separated words and only execs the first one. Is there anything I can pass to cause any sort of damage in one word? Btw webserver runs... (1 Reply)
Discussion started by: aydinh
1 Replies
8. Solaris
:confused:
when i tried to look the status of DNS-client, it is in maintenance mode.....
Please tell me how to bring it back to online mode...PLEASE TELL ME STEP BY STEP.... PLEASE...
:wall: (2 Replies)
Discussion started by: vamshigvk475
2 Replies
9. HP-UX
is there a way for my C++ application to find out which mode the hpux OS is running in?
standard mode or trusted mode. (3 Replies)
Discussion started by: einsteinBrain
3 Replies
LEARN ABOUT HPUX
hp9000s700
machid(1) General Commands Manual machid(1)
NAME
machid: hp9000s200, hp9000s300, hp9000s400, hp9000s500, hp9000s700, hp9000s800, hp-mc680x0, hp-pa, pdp11, u370, u3b, u3b10, u3b2, u3b5, vax
- provide truth value about processor type
SYNOPSIS
DESCRIPTION
The following commands return a true value (exit code 0) if the a processor type matches the command name. Otherwise a false value (exit
code nonzero) is returned. These commands are commonly used within makefiles and shell procedures to improve portability of applications
(see make(1)).
+-----------+-------------------------++--------+--------------------------+
|Command | True for ||Command | True for |
+-----------+-------------------------++--------+--------------------------+
|hp9000s200 | Series 200 ||pdp11 | PDP-11/45 or PDP-11/70 |
|hp9000s300 | Series 300 ||u3b | 3B20 computer |
|hp9000s400 | Series 400 ||u3b2 | 3B2 computer |
|hp9000s500 | Series 500 ||u3b5 | 3B5 computer |
|hp9000s700 | Series 700 ||u3b10 | 3B10 computer |
|hp9000s800 | Series 800 or 700 ||u370 | IBM System/370 computer |
|hp-mc680x0 | Series 200, 300, or 400 ||vax | VAX-11/750 or VAX-11/780 |
|hp-pa | Series 700 or 800 || | |
+-----------+-------------------------++--------+--------------------------+
EXAMPLES
Given a shell script that must behave differently when run on an HP 9000 Series 700 or 800 system, select the correct code segment to be
executed:
WARNINGS
always returns true on both Series 800 and Series 700 systems. Therefore, when using this command in scripts to determine hardware type,
always use both and in the appropriate sequence to ensure correct results (see
machid(1) will no longer provide support for future machines beyond the Series 800 and Series 700 systems. Decisions should be based on
the hardware and software configuration information returned by getconf(1).
SEE ALSO
getconf(1), make(1), sh(1), test(1), true(1).
machid(1)