05-20-2012
I would not touch this if I were you. Ask an experienced HP-UX admin in your company to have a look...
10 More Discussions You Might Find Interesting
1. Solaris
I dont even know what raid level this is, but its raid 5 mirrored from the looks of it.
I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies
2. AIX
Hi Experts,
I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics.
pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D
SSA160 Physical Disk Drive ( MB)
Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies
3. Solaris
Hi,
Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great.
# uname –a
SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4
#df -k
Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies
4. HP-UX
Requirement to remove a faulty mirrored disk from hp-ux LVM
<root@pdwp1s>/etc # vgdisplay -v /dev/vg00
vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0":
The specified path does not correspond to physical volume attached to
this volume group
vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies
5. HP-UX
Hi,
Have mirrored the primary disk to 3 .
Server and OS:
# uname -a
HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license
# model
9000/800/L3000-7x
# strings /etc/lvmtab
/dev/vg00
+F@<
/dev/dsk/c1t2d0
/dev/dsk/c2t2d0
/dev/dsk/c2t0d0
But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies
6. Solaris
Hi Guys,
One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine
But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies
7. AIX
Hi,
One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes.
The errpt keeps reporting stale partition error.
lvs are in open/stale state.
In this sceanario is replacing the disk the best practice?
When i do a lsdev the disk is labelled as below.
hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies
8. Filesystems, Disks and Memory
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Discussion started by: terrya
1 Replies
9. AIX
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (3 Replies)
Discussion started by: terrya
3 Replies
10. UNIX for Beginners Questions & Answers
I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply)
-> show faulty
Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies