Operating Systems Solaris Hardware RAID not recognize the new disk [Sun T6320] Post 302598365 by rock123 on Tuesday 14th of February 2012 08:12:39 AM
Old 02-14-2012
Hardware RAID not recognize the new disk [Sun T6320]

We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue.

We have 2 LDOM configured on this server and this server running on single disk.

Code:
# raidctl -l
Controller: 0
        Volume:c0t0d0
        Volume:c0t2d0
        Disk: 0.1.0
        Disk: 0.3.0
        Disk: 0.4.0

# raidctl -l c0t0d0
Volume                  Size    Stripe  Status   Cache  RAID
        Sub                     Size                    Level
                Disk
----------------------------------------------------------------
c0t0d0                  136.6G  N/A     DEGRADED ON     RAID1
                0.1.0   136.6G          GOOD
                N/A     136.6G          FAILED

# raidctl -l c0t2d0
Volume                  Size    Stripe  Status   Cache  RAID
        Sub                     Size                    Level
                Disk
----------------------------------------------------------------
c0t2d0                  136.6G  N/A     OPTIMAL  ON     RAID1
                0.4.0   136.6G          GOOD
                0.3.0   136.6G          GOOD


Last edited by DukeNuke2; 02-14-2012 at 10:00 AM..
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

Sun T5120 hardware RAID question

Hi everyone I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive. My question is, how would I know when one of the drives become faulty? Thanks (2 Replies)
Discussion started by: soliberus
2 Replies

3. Solaris

Add new disk to Sun StorEdge 3310 RAID

HI guys. Bit of a noob so bear with me. I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was... (4 Replies)
Discussion started by: jamie_collins
4 Replies

4. Hardware

Sun Blade T6320 memory configuration

Can you mix DIMMs in a T6320 (sparc) blade? I have read/heard that the DIMMs in a memory bay must be identical but can you have different size DIMMs installed in the blade? For instance, can you have 1 4GB DIMM in bay 0, 2 2GB DIMMs in bay 1, 4 1 GB DIMMs in bay 2 and 2 2GB DIMMs in bay 3 for a... (0 Replies)
Discussion started by: bluescreen
0 Replies

5. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

6. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

7. Solaris

Solaris recognize HW Raid ??

Hardware: HP P2000 HP DL380 G7 with Solaris Software: Solaris 10 05/08 I had made a Hardware raid on P2000 and install solaris on G7, The raid card controller is working fine. How can I make the raid works on OS?? "raidclt" is getting nothing :wall::wall: Thanks (11 Replies)
Discussion started by: stanley1024
11 Replies

8. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

9. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies
vxbootsetup(1M) 														   vxbootsetup(1M)

NAME
vxbootsetup - set up system boot information on a Veritas Volume Manager disk SYNOPSIS
/etc/vx/bin/vxbootsetup [-g diskgroup] [medianame ... ] DESCRIPTION
The vxbootsetup utility configures physical disks so that they can be used to boot the system. Before vxbootsetup is called to configure a disk, the required volumes, standvol, rootvol and swapvol (and optionally, dumpvol) must be created on the disk. All of these volumes must be contiguous with only one subdisk. The -g option may be used to specify the boot disk group. If no medianame arguments are specified, all disks that contain usable mirrors of the root, swap, /usr and /var volumes are configured to be bootable. If medianame arguments are given, only the disks that are associated with the specified disk names are configured to be bootable. vxbootsetup requires that: o The root volume must be named rootvol and must have a usage type of root. o The swap volume must be named swapvol and must have a usage type of swap. o The volumes containing /usr and /var (if any) must be named usr and var, respectively. See the chapter "Recovery from Boot Disk Failure" in the Veritas Volume Manager Troubleshooting Guide for detailed information on how the system boots and how VxVM impacts the system boot process. The vxmirror, vxrootmir, and vxresize utilities call vxbootsetup automatically. If you use vxassist, or vxmake and vxplex to create mirrors of the root volume on a disk, you must run vxbootsetup explicitly to make the disk bootable. ARGUMENTS
medianame Specifies the disk name (disk media name) of a VM disk that is to be configured as bootable. SEE ALSO
disksetup(1M), edvtoc(1M), vxassist(1M), vxevac(1M), vxinstall(1M), vxintro(1M), vxmake(1M), vxmirror(1M), vxplex(1M), vxresize(1M), vxrootmir(1M) Veritas Volume Manager Troubleshooting Guide VxVM 5.0.31.1 24 Mar 2008 vxbootsetup(1M)
All times are GMT -4. The time now is 03:25 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy