Sponsored Content
Operating Systems Solaris Software RAID on top of Hardware RAID Post 302582406 by fpmurphy on Thursday 15th of December 2011 08:32:37 PM
Old 12-15-2011
What not go the ZFS route instead? It gives you everything that Veritas Volume Manager or SVM provides and lots more.
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

3. Solaris

T2000 Hardware RAID

Hi, I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds. I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this? AVAILABLE DISK SELECTIONS: 0.... (12 Replies)
Discussion started by: honmin
12 Replies

4. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

5. Solaris

Hardware Raid - LiveUpgrade

Hi, I have a question. Do LiveUpgrade supports hardware raid? How to choose the configuration of the system disk for Solaris 10 SPARC? 1st Hardware RAID-1 and UFS 2nd Hardware RAID-1 and ZFS 3rd SVM - UFS and RAID1 4th Software RAID-1 and ZFS I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies

6. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

7. Solaris

Hardware to software RAID migration

We have hardware RAID configured on our T6320 server and two LDOMs are running on this server. One of our disk got failed and replaced. After replacemnt the newly installed disk not detected by RAID controlled so Oracle suggested to upgrade the REM firmware. As this is the standalone production... (0 Replies)
Discussion started by: rock123
0 Replies

8. Solaris

Hardware raid patching

Dear All , we have hardware raid 1 implemented on Solaris Disks. We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers. Thanks... Rj (7 Replies)
Discussion started by: jegaraman
7 Replies

9. Solaris

Hardware RAID using three disks

Dear All , Pl find the below command , # raidctl -l Controller: 1 Volume:c1t0d0 Disk: 0.0.0 Disk: 0.1.0 Disk: 0.3.0 # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
vxiod(1M)																 vxiod(1M)

NAME
vxiod - start, stop, and report on Veritas Volume Manager I/O threads SYNOPSIS
vxiod vxiod [-f ] [set count] DESCRIPTION
The vxiod utility starts, stops, or reports on Veritas Volume Manager (VxVM) I/O kernel threads. An I/O thread provides a process context for performing I/O in VxVM. When the vxio module is loaded, 16 I/O threads are created, plus 2 threads per additional CPU for a system with more than 8 CPUs, up to a maximum of 64 threads. At least one I/O thread must be running while the vxio module is loaded, and the number of I/O threads cannot be forced to zero. When invoked with no arguments, vxiod prints the current number of I/O threads to the standard output. The number of threads that is required for handling I/O requests depends on the system load and usage. If volume recovery seems to proceed more slowly at times, it may be possible to improve its performance by increasing the number of I/O threads up to a maximum of 64. KEYWORDS
set When invoked with the set keyword, vxiod creates the number of I/O threads specified by count. If more volume I/O threads exist than are specified by count, the excess processes terminate. If more than the maximum number(64) are specified, the requested number is silently truncated to that maximum. OPTIONS
-f This option has no effect from release 5.0 onward. The number of I/O threads cannot be reduced to zero. EXIT CODES
The vxiod utility prints a diagnostic on the standard error, and exits if an error is encountered. If an I/O request occurs within a I/O thread, the state of that I/O request is not reflected in the exit status for vxiod. Otherwise, vxiod returns a non-zero exit status on error. Usage errors result in an exit status of 1 and a usage message. If the requested number of threads cannot be created, the exit status is 2, and the number of threads that were successfully started is reported. If any other error occurs, the exit status is 3. FILES
/dev/vx/iod The device used to report on and start volume I/O threads. NOTES
Veritas Volume Manager I/O threads cannot be killed directly through the use of signals. Depending on the operating system, VxVM I/O threads may not appear in the list of processes that is output by the ps command. The number of I/O threads that is currently running can be determined by running vxiod. SEE ALSO
fork(2), ps(1), vxconfigd(1M), vxdctl(1M), vxintro(1M), vxio(7), vxiod(7) VxVM 5.0.31.1 24 Mar 2008 vxiod(1M)
All times are GMT -4. The time now is 05:18 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy