07-05-2010
Quote:
Originally Posted by
pludi
Looks like something happened to the /etc/fstab file, or maybe even to the initrd. Can you boot up the Live-CD and post the content of the fstab file?
I have booted from RH DVD via linux rescue switch to chroot /mnt/sysimage (linked to /dev/sda1).
Listing of my
fstab is here:
listing of
fdisk -l | more here:
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
hello :-)
I have one problem with my LiLO... I installed PLD Linux on my computer but when it boots, the last thing I can see is:
request_module Root fs not mounted
VFS: Cannot open root device 03:01
Kernel panic: VFS: unable to mount root fs on 03:01
and the system stops :-(
what... (1 Reply)
Discussion started by: pgas
1 Replies
2. UNIX for Advanced & Expert Users
I've got htis message on our sun U60 machine:
"Reboot after panic:errID 0x000004eff........." ,this message have been issued on the /var/adm/messages file & cause system rebooting randomly.
Any comment.
Thanks,
--Nikk (1 Reply)
Discussion started by: nikk
1 Replies
3. Linux
I have compiled kernel version 2.6.12 in my linux box mandrake 10.1. I have followed www.digitalhermit.com/linux/Kernel-Build-HOWTO.html instructions. I have copied .config file from /usr/src/linux and lightly modified it (only the processor type) by xconfig. I have compiled the source and modules.... (3 Replies)
Discussion started by: Davide71
3 Replies
4. UNIX for Advanced & Expert Users
One of our servers keeps crashing.
Here is the following message that we get:
11:01 Thu Aug 31 2006. Reboot after panic: fcpbh_scsi_comp: Inbound data overf
low
12:28 Wed Sep 6, 2006. Reboot:
16:12 Wed Sep 06 2006. Reboot after panic: , isr.ior = 0'10240070.0'dcf72938
Does anyone... (1 Reply)
Discussion started by: shoultsc
1 Replies
5. Solaris
Hi Guru's
Can any want here could explain to me the different between soft reboot and hard reboot .
Best Regards
Seelan (3 Replies)
Discussion started by: seelan3
3 Replies
6. AIX
Dear Gurus,
I would like to know if fsck is executed automatically during reboot for AIX?
Is there any logs which I can refer to? or any documentation reference for this?
Thank You. (2 Replies)
Discussion started by: cteoh88
2 Replies
7. Linux
ok so I just installed fedora core 6 on my dell inspiron 700m and I go to boot into linux and I get this error. Has anyone seen this before?
I also had XP Pro and Vista installed on this pc prior to putting fedora core 6 on the machine. I'm trying to setup a triple boot system.
Please Help... (2 Replies)
Discussion started by: dave043
2 Replies
8. HP-UX
Hi all,
Does anybody know what kinds of events can prompt the following?
I found our test db box had rebooted itself. I'd like to know how I can go about finding our why. Thanks folks... (1 Reply)
Discussion started by: Kozmo
1 Replies
9. Solaris
ho do you check filesystem on entire hard disk? (9 Replies)
Discussion started by: orange47
9 Replies
10. Solaris
Solaris 8
running on a Sparcstation 5 (Aurora) with 170MHz processor and 256MB ram
This is AFTER doing fsck and reboot.
820030k vs 385252k
All other files in /usr/asm not in /usr/asm/sys or /usr/asm/data amount to 43k. The /usr/asm/lost+found is 8k. somehow df and other applications... (3 Replies)
Discussion started by: lcoreyl
3 Replies
LEARN ABOUT FREEBSD
mlxcontrol
MLXCONTROL(8) BSD System Manager's Manual MLXCONTROL(8)
NAME
mlxcontrol -- Mylex DAC-family RAID management utility
SYNOPSIS
mlxcontrol <command> [args]
mlxcontrol status [-qv] [drive]
mlxcontrol rescan controller [controller ...]
mlxcontrol detach drive [drive ...]
mlxcontrol detach -a
mlxcontrol check drive
mlxcontrol config controller
mlxcontrol help command
DESCRIPTION
The mlxcontrol utility provides status monitoring and management functions for devices attached to the mlx(4) driver.
Controller names are of the form "mlxN" where N is the unit number of the controller. Drive names are of the form "mlxdN" where N is the
unit number of the drive. Do not specify the path to a device node.
status Print the status of controllers and system drives. If one or more drives are specified, only print information about these drives,
otherwise print information about all controllers and drives in the system. With the -v flag, display much more verbose informa-
tion. With the -q flag, do not print any output. This command returns 0 if all drives tested are online, 1 if one or more drives
are critical and 2 if one or more are offline.
rescan Rescan one or more controllers for non-attached system drives (e.g. drives that have been detached or created subsequent to driver
initialisation). If the -a flag is supplied, rescan all controllers in the system.
detach Detach one or more system drives. Drives must be unmounted and not opened by any other utility for this command to succeed. If the
-a flag is supplied, detach all system drives from the nominated controller.
check Initiate a consistency check and repair pass on a redundant system drive (e.g. RAID1 or RAID5). The controller will scan the system
drive and repair any inconsistencies. This command returns immediately; use the status command to monitor the progress of the
check.
rebuild Requires two arguments, controller and physdrive as specified in the output of the status command. All system drives using space on
the physical drive physdrive are rebuilt, reconstructing all data on the drive. Note that each controller can only perform one
rebuild at a time. This command returns immediately; use the status command to monitor the progress of the rebuild.
config Print the current configuration from the nominated controller. This command will be updated to allow addition/deletion of system
drives from a configuration in a future release.
help Print usage information for command.
AUTHORS
The mlxcontrol utility was written by Michael Smith <msmith@FreeBSD.org>.
BUGS
The config command does not yet support modifying system drive configuration.
Error log extraction is not yet supported.
BSD
April 10, 2000 BSD