Sponsored Content
Operating Systems Solaris Sun T5120 hardware RAID question Post 302402542 by soliberus on Wednesday 10th of March 2010 05:16:22 AM
Old 03-10-2010
Sun T5120 hardware RAID question

Hi everyone

I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive.

My question is, how would I know when one of the drives become faulty?

Thanks
 

9 More Discussions You Might Find Interesting

1. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

2. Solaris

How to destroy hardware raid on T5120

Hi, I have problem creating hardware raid on T5120 with 4 disks. After the hardware raid 1 created, then I used the raidctl -l c1t0d0 and raidctl -l c1t2d0 the output of volume c1t0d0 contain disk 0.0.0 0.1.0, also the volume c1t2d0 contain disk 0.0.0 0.1.0 and should be 0.2.0 0.3.0 so I... (15 Replies)
Discussion started by: netlink
15 Replies

3. Solaris

Small issue with Sun Sparc Enterprise T5120

Good Day, We have bought Sun Sparc Enterprise T5120 with pre-installed Solaris 10 Sparc But i need on this server Solaris 9. I have inserted in to DVD-rom (USB DVD-rom) with Solaris 9 for Sparc. Then log into shell and type: reboot -- cdrom. System rebooted and i have this message: ... (3 Replies)
Discussion started by: A.Shalin
3 Replies

4. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

5. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

6. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Sun V240 Raid Question

Hi All, I'm new to this site. I have a few question since I'm in the process how to to repair my raid on Sun V240 Server. 1. How can we create RAID in Sun Sparc v240? 2. What utility can help people create RAID in Sun Sparc v240? 3. Do we need any special software to create the... (12 Replies)
Discussion started by: angkor
12 Replies

9. Solaris

Hardware RAID not recognize the new disk [Sun T6320]

We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue. We have 2 LDOM configured on this server and this server running on single disk. #... (8 Replies)
Discussion started by: rock123
8 Replies
saconfig(1M)															      saconfig(1M)

NAME
saconfig - Command Line Configuration Utility for the HP SmartArray RAID Controller Family SYNOPSIS
<device_file> <device_file> -N <device_file> -R <RAID_level> [-S <stripe_size>] -p <physical_drive_id> [-p <physical_drive_id> ...] [-s <physical_drive_id>] [-c <capac- ity>] <device_file> -e <low|medium|high> <device_file> -r <low|medium|high> <device_file> -P <default|shortest|longest> <device_file> -A <logical_drive_num> -s <physical_drive_id> <device_file> -D <logical_drive_num> -s <physical_drive_id> <device_file> -D <logical_drive_num> -s all <device_file> -D <logical_drive_num> <device_file> -D all <device_file> -C <read_caching_percentage> <device_file> -F on <device_file> -F off <device_file> -I -p <physical_drive_id> [-p <physical_drive_id> ...] <device_file> -I -l <logical_drive_num> <device_file> -E <logical_drive_num> -c <capacity> <device_file> -E <logical_drive_num> -p <physical_drive_id> [-p <physical_drive_id> ...] <device_file> -M <logical_drive_num> -R <RAID_level> [-S <stripe_size>] <device_file> -M <logical_drive_num> -S <stripe_size> DESCRIPTION
The command is a command line configuration tool for the HP SmartArray RAID Controller Family. This command provides the ability to create a logical drive, add a spare drive to existing logical drive, display configuration, delete a logical drive, and clear configuration. This command also enables the cache when it is used to create the first logical drive on the SmartArray RAID Controller. Furthermore it allows the option of changing the percentage of total cache size used for read caching and write caching. The auto-fail missing disks at boot fea- ture can be enabled or disabled using this command. Prerequisites needs to be able to create the /tmp/saconfig.lock file when it starts executing. This prevents multiple users from running This lock file is removed when exits. Security Restrictions requires either the superuser privilege or and privileges. See privileges(5) for more information about privileged access on systems that support fine-grained privileges. Options recognizes the following options and parameters as indicated in the SYNOPSIS section above. <device_file> To specify the device file for the SmartArray RAID Controller. The device file is as displayed by the command for the appropriate SmartArray RAID Controller. With no other options, displays size and status for all physical drives and RAID level, size, and status for all logical drives. With the option saconfig displays size and status for all physical drives and RAID level, size, and status for all logical drives. But the persistent device files (see intro(7)) will be displayed as against legacy device files in the absence of this option. -R <RAID_level> To create a logical drive with the specified RAID level. The supported RAID levels are 0, 1, 1+0, 5, and ADG. The lowest logical drive number not already in use will be given to the newly created logical drive, starting from 0. To determine the hardware path and device file for the logical drive, use the command. The logical drives are dis- played in the same order as in the output. RAID 1+0 logical drive requires even number of physical drives (minimum of 2). To achieve optimal fault tolerance, it is best to specify the same number of physical drives per channel if possible when creating a RAID 1+0 logical drive. This ensures the physical drives in each mirrored pairs would be on different channels. -S <stripe_size> To specify the stripe size for the logical drive to be created. The supported stripe sizes are 8, 16, 32, 64, 128, and 256 (KB). 128 and 256 stripe sizes are not available for RAID 5 or ADG logical drive. If this option is not used to specify the stripe size, default stripe size will be used to create the logical drive. For RAID 0 and 1+0 logical drive, the default size is 128. For RAID 5 and ADG logical drive, the default size is 16. -p <physical_drive_id> To specify the SCSI physical disk. It can be represented as <channel_id>:<target_id> (e.g., 4:12). Valid channel numbers are between 1 and 4. Valid target numbers are between 0 and 15. To specify the SAS/SATA physical disk. It can be represented as either <connector>:<enclosure>:<bay> (e.g., 2I:1:10) or <wwid> (e.g., 0x500000e010f16432). -s <physical_drive_id> To specify a spare drive to be included in the logical drive configuration. Refer <physical_drive_id> to -p option. -c <capacity> To specify the size in GB of a logical drive to be created. -A <logical_drive_num> To specify which logical drive to add spare drive to. -e <low | medium | high> To change the expand priority of controller to one of Low, Medium, High. When there are no logical drives, expand priority cannot be changed. When the configuration is cleared, or the last logical drive is deleted, the subse- quent logical drive creation will change the expand priority value of the controller to medium. -r <low | medium | high> To change the rebuild priority of controller to one of Low, Medium, High. When there are no logical drives, rebuild priority cannot be changed. When the configuration is cleared, or the last logical drive is deleted, the subsequent logical drive creation will change the rebuild priority value of the controller to high. -P <default | shortest | longest> To change the path selection method by the controller firmware. If it is set to default, firmware will select the Active path on its own. If the selection method is set to shortest, firmware will select the shortest path as the Active Path. If the path selection method is longest, firmware will select the longest path as the Active Path. All multi path configurations are Active-Standby configurations. -D <logical_drive_num> -s <physical_drive_id> To delete the spare drive from the specified logical drive. -D <logical_drive_num> -s all To delete all of spare drives from the specified logical drive. -D <logical_drive_num> To delete the specified logical drive. -D all To clear configuration. -C <read_caching_percentage> To specify the percentage of total cache size to be used for read caching. The remaining percentage will be used for write caching. Valid read caching percentage numbers are 0, 25, 50, 75, and 100 (%). -F on To enable auto-fail missing disks at boot feature. -F off To disable auto-fail missing disks at boot feature. -I -p <physical_drive_id> [-p <physical_drive_id> ...] To identify SAS/SATA physical drive(s) by LED. -I -l <logical_drive_num> To identify a SAS/SATA logical drive by LED. -E <logical_drive_num> -c <capacity> To extend the capacity of the specified logical drive up to larger capacity. The capacity is in GB. -E <logical_drive_num> -p <physical_drive_id> [-p <physical_drive_id> ...] To expand the specified logical drive and others in an array by physical drive(s). -M <logical_drive_num> -R <RAID_level> [-S <stripe_size>] To perform RAID level [with stripe size] migration on the specified logical drive. The stripe size is in KB. -M <logical_drive_num> -S <stripe_size> To perform stripe size migration on the specified logical drive. The stripe size is in KB. Logical Drive State Definitions All physical disks in the logical drive are operational. Some possible causes: Multiple physical disks in a fault-tolerant (RAID 1, 1+0, 5, ADG) logical drive have failed. One or more disks in a RAID 0 logical drive have failed. Cache data loss has occurred. Array expansion was aborted. The logical drive is temporarily disabled because another logical drive on the controller had a missing disk at power-up. Also known as "degraded" state. A physical disk in a fault tolerant logical drive has failed. For RAID 1, 1+0 or 5, data loss may result if a second disk should fail. For RAID ADG, data loss may result if two additional disks should fail. A replacement disk is present, but rebuild hasn't started yet (another logical drive may be currently rebuilding). The logical drive will also return to this state if the rebuild had been aborted due to unrecoverable read errors from another disk. One or more physical disks in this logical drive are being rebuilt. While the logical drive was in a degraded state, the system was powered off and a disk other than the failed disk was replaced. Shut off the system and replace the correct (failed) disk. While the system was off, one or more disks were removed. Note: the other logical drives are held in a temporary "failed" state when this occurs. The data in the logical drive is being reorganized because: Physical disks have been added to the array (capacity expansion). The stripe size is being changed (stripe-size migration). The RAID level is being changed (RAID-level migration). A capacity expansion operation is in progress (or is queued up) that will make room on the disks for this new logical drive. Until room has been made on the physical disks, this newly configured logical drive cannot be read or written. The logical drive is waiting to undergo data reorganization (see EXPANDING above). Possible causes for the delay are a rebuild or expansion operation may already be in progress. Physical Disk State Definitions The physical disk is configured in one or more logical drives and is operational. The physical disk is configured as a spare disk. The physical disk has not been configured in any logical drives. The configured physical disk has failed. Return Value returns the following values: Successful completion. Command line syntax error. Incompatible CISS driver API. Failure opening a file. Other error. Examples To display configuration on the SmartArray RAID Controller /dev/ciss5 - To create a RAID 1+0 logical drive to include physical drives 4:0 and 4:1 and spare drive 4:2 - -R -p -p -s To create a RAID ADG logical drive with stripe size 64 to include physical drives 1:2, 2:2, 3:2 and 4:2 - -R -S -p -p -p -p To create a RAID 5 logical drive with capacity 45 GB to include SAS physical drives 1I:1:16, 1I:1:15, and 1I:1:14 - -R -c -p -p -p To set the expand priority of logical drives on a controller to medium -e To set the rebuild priority of logical drives on a controller to high -r To add spare drive 1:0 to logical drive 1 - -A -s To delete spare drive 1:0 from logical drive 1 - -D -s To delete all spare drives from logical drive 1 - -D -s To delete logical drive 0 - -D To clear configuration - -D To change read caching percentage to 75% - -C To extend logical drive 2 upto 45 GB in capacity - -E -c To expand logical drive 0 with 2 SAS physical drives - -E -p -p To migrate logical drive 2 with stripe 32 - -M -S To migrate logical drive 2 to RAID level 5 with stripe 64 - -M -R -S AUTHOR
was developed by HP. FILES
Executable file. saconfig lock file. Device files. SEE ALSO
sautil(1M), privileges(5), intro(7). saconfig(1M)
All times are GMT -4. The time now is 08:34 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.