Top Forums UNIX for Dummies Questions & Answers Help!! Failing HP-UX 11 system disk Post 302371038 by rees_a on Friday 13th of November 2009 07:39:05 AM
Old 11-13-2009
Help!! Failing HP-UX 11 system disk

Firstly, system setup -

HP900 K460, 3 internal hard drives that make up the system volume group(vg00) no software mirroring

HP-ux version 11.00

2 Nike 20 raid arrays attached, fully populated with 40 4gb hot swap drives(All used in production environment)

I have 3 disks that make up my root volume group(VG00). 1 of them is making a very load noise so I think its going to fail sometime soon. (Not sure which one)

I also have a number of other volume groups/disks running on 2 nike 20 disk arrays

The questions I have are -

I would like to know if its possible to clone or copy the failing disk onto another drive whilst it is still running then boot from the cloned disk.(I have no spare drive so will need to add one?

I have a make_tape_recovery backup, if I have to restore from that tape(Not sure how I do that) will I also need to restore all the other volume groups even though they are on separate disks or will they continue to function once the system has been restored from the tape.

I vaguely remember doing a recovery about 8 years ago using the make_tape_recovery which worked fine and the other disks carried on working

I'm a bit of a Unix novice so step by step instructions would be great

Just to be doubly sure, can you confirm the make_tape_Recovery options I should use to ensure I can restore my system disks should the noisy disk fail.

Hi there, sorry for long post, I've just checked the drives in SAM and 1 of them is a 4gb Swap disk(Lvol9) if that is the failing disk, is it possible to remove the swap disk, replace with new disk and add swap to that disk(If this makes sense). I'm assuming in this instance I can just delete the swap
would this be right?

Last edited by rees_a; 11-13-2009 at 09:52 AM..
 
Test Your Knowledge in Computers #982
Difficulty: Medium
NetBSD is a free and open-source Unix-like operating system based on the Berkeley Software Distribution (BSD).
True or False?

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

System crash and Disk erasure !!!

I need some expert help, and would appreciate any feedback on the following problem: After power outage the machine didn't allow the login. When we checked it , it looked like both disks were completely empty. Luckily, we have a backup machine, and we can restore the disks. Has anybody seen... (3 Replies)
Discussion started by: DGoubine
3 Replies

2. Shell Programming and Scripting

adding a disk to unix system.

Hello everybody, I am traying to add a new external hard disk (300 GB Seagate ST3300007LW) to our Ultra-I SUN Workstation running Solaris 2.6 operating system. System recognizes the hard disk on target id=13, and I am able to reboot with the command "boot -r". However the "format" command... (0 Replies)
Discussion started by: geophysics
0 Replies

3. Filesystems, Disks and Memory

Mirror system disk

I have a SUN 440 running Solaris 8 that is generating funny errors on /dev/dsk/c1t0d0 and I would like to dupe the drive(the non offending drives are removed for this process), swap it with the dupe and reboot. From what I have read, the process seems simple: dd if=/dev/dsk/c1t0d0... (1 Reply)
Discussion started by: hardyj
1 Replies

4. UNIX for Advanced & Expert Users

Failing to write retrieve script for tape to disk conversion

I have the below script which has been written to retrieve files from tape drive i.e. TSM server. Now i have to write the script using UNIX commands for retrieve operation but I am not able to proceed. The script is: #!/usr/local/bin/expect -f set timeout 1800 set file spawn $env(SHELL)... (0 Replies)
Discussion started by: hrsaurav
0 Replies

5. UNIX for Dummies Questions & Answers

Mounting a floppy disk in System V

Hello all! I just recently inherited a mid-90s gateway full tower system (Original Pentium, SIMM style RAM, etc.). I had always wanted to try an old version of UNIX, and having come across a copy of AT&T System V R4 decided that the time was ripe. There were 30 disks total, and after booting to... (1 Reply)
Discussion started by: Northcott
1 Replies

6. UNIX for Dummies Questions & Answers

copy failing disk to Spare

Hi Guys, I have a failing 4gb (c0t5d0) drive that contains lvol4 -8 on hp-ux. It's not the boot disk but is part of VG00 volume group. Within that group, I have a disk (c0t4d0) of the same size that has 1 lvol on it for swap(4gb) I also have a seperate 1.5 gb swap volume on another physical disk... (1 Reply)
Discussion started by: rees_a
1 Replies

7. Infrastructure Monitoring

SNMP responses failing under high system load

Greetings, I've got a Zenoss v2.5 server monitoring a large video encoding farm. Needless to say, these systems are under high bandwidth and CPU utilization the majority of the time. What I'm running into is that, occasionally, these systems will fail to respond to a standard SNMP request,... (1 Reply)
Discussion started by: Karunamon
1 Replies

8. Solaris

backup the whole system to a usb disk.

Hi dears, im working with a sun sparc server(M4000) , solaris 10 installed. I need a little help, because i wanna know if is it possible to backup the whole system in a usb disk. Im gonna explain you a little more why i want to do it. Currently i have installed a Solaris 10 working with... (5 Replies)
Discussion started by: botella
5 Replies

9. Solaris

Recover failed system disk

I have an oldish Solaris 10 system (SunFire x4240), which due to a recent heating event in the server room, lost it's system disk. I have rsync backups of all the other (data) disks, but apparently I do not have a backup of /. :-( I can start the machine up in failsafe mode, but running fsck on... (4 Replies)
Discussion started by: jj5406
4 Replies

10. AIX

Failing to add new NetApp disk AIX 7.1 - but no error

Hello, AIX 7.1 - several NetApp disks already running. Trying to install a new one. Storage folks provision it. I run cfgmgr - nothing. no new disks show up in "lsdev", "sanlun lun show" shows no new device. No errors, just nothing. Storage guys disconnect it and attaches to another aix server -... (5 Replies)
Discussion started by: sid
5 Replies
voldiskadd(8)						      System Manager's Manual						     voldiskadd(8)

NAME
voldiskadd - Adds one or more disks for use with the Logical Storage Manager SYNOPSIS
/usr/sbin/voldiskadd disk-address-list DESCRIPTION
The voldiskadd utility sets up new disks that are added to the system after the initial system installation and configures the disks for use by the Logical Storage Manager. A valid disk label must exist on the disk before using the voldiskadd utility. One or more disks may be specified using a disk-address-list. Disk addresses in the list have the form dskn (for the entire disk) or dsknp (for a specific partition). When specifying multiple disks, use a space between entries. Disk address names relate directly to device names in the /dev/disk directory. For example, here are some valid voldiskadd disk-address-list specifications: # voldiskadd dsk1 # voldiskadd dsk2 dsk3a The file, /etc/vol/disks.exclude, may be used to exclude disks from use by voldiskadd. Each line of the file specifies the name of a disk to exclude (for example, dsk5). The voldiskadd utility prompts the user for a disk group name and disk media name for the disks. If a new disk group name is specified, that disk group is created for the new disks. If no disk group name is specified, the disks are left as unassigned replacement disks for future use. If an existing disk group name is specified, the user is prompted for whether the disks should be designated as spares for the disk group. If a disk is found to already contain non-Logical Storage Manager partitioning, the user is asked whether the disk should be encapsulated. Encapsulation turns each partition of the disk into a volume. A disk should be encapsulated if it contains file systems or data that should not be overwritten. If encapsulation is not desired for a disk, the disk can be initialized as a new disk for use by the Logical Storage Manager. For new disks, all space on the disk becomes free space in the disk's disk group. Context-sensitive help is available at every prompt by typing ?. Also, a list option can be used to get information on available target disks for an operation. The voldiskadd utility supports the following general classes of actions: Initializing a disk with reserved regions and partitions. Disk initialization is performed by calling voldisksetup command. Adding a disk to an existing disk group. This operation can be performed independently of the initialization of the disk drive to add a disk's storage space to a disk group's free space pool. The volassist command may subsequently allocate from that free space. The disk can also be added as a hot spare device. Creating new disk groups in which to import new disks. If no disk group exists for importing disks, the option of creating the disk group is offered. Encapsulating disks that have exist- ing contents. This is the default action for disks that do not have a valid, existing Logical Storage Manager private region, but that do have a disk label. Encapsulation is performed by calling volencap. Reconnecting a drive that was temporarily inaccessible. This situation is detected automatically, by noting that the specified drive has a disk ID that matches a disk media record with no currently associated physical disk. After reconnection, any stale plexes referring the disk are reattached, and any stopped volumes referring the disk are restarted. This reattach action is performed by calling the volrecover script. ERRORS
You may receive the following messages when using the voldiskadd command: Initialization of disk device special-device failed. Error: special-device or an overlapping partition is open. This message indicates that the partition you specified or an overlapping partition on the disk is actively in use. The partition could be a mounted UFS or AdvFS filesystem, initialized as an LSM disk or used as a swap device. special-device is marked in use for fstype in the disklabel. If you continue with the operation you can possibly destroy existing data. Would you like to continue?? [y,n,q,?] (default: n) This message indicates that the fstype of a partition or an overlapping partition is set in the disk label. The voldiskadd command prints this message to warn that a disk partition may have valid data which could be destroyed. If you are sure that the disk partition does not have valid data and that the partition can be added to LSM, you can ignore the warning message by entering y at the prompt. The voldiskadd command will proceed to initialize the disk partition and add it to LSM. FILES
A list of disks to exclude from use by voldiskadd. SEE ALSO
disklabel(8), volassist(8), voldisk(8), voldiskadm(8), voldisksetup(8), voldg(8), volintro(8) voldiskadd(8)

Featured Tech Videos

All times are GMT -4. The time now is 02:06 AM.
Unix & Linux Forums Content Copyright 1993-2020. All Rights Reserved.
Privacy Policy