Sponsored Content
Full Discussion: Help growing iscsi lun
Operating Systems AIX Help growing iscsi lun Post 302362263 by bbbngowc on Thursday 15th of October 2009 11:56:56 AM
Old 10-15-2009
Still no luck with growing this volume. Do I have to take the system offline or at least the volume for it to see the additional space?
 

9 More Discussions You Might Find Interesting

1. Solaris

I have LUN ID, how to find disk relate to that LUN ID?

I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer. thanks (4 Replies)
Discussion started by: uuontario
4 Replies

2. Solaris

Set up iscsi LUN on solaris 9?

Hi, I need to set up iscsi LUN on Solaris 9. I've done it on Solaris 10 with iscsiadm. How do you do it on Solaris 9 though? Currently using Solaris 9 update 2. Your help is appreciated. Thanks, Sparcman (6 Replies)
Discussion started by: sparcman
6 Replies

3. Solaris

Solaris10 -> iscsi -> equiliogic lun

We "lose" the iscsi device after a reboot - i.e., it appears in /dev/rdsk and /dev/dsk but format cannot find it. Obviously, it won't mount either. This happens for two separately defined luns. We must be missing a step in iscsiadm. The luns are defined as targets, we can see them in... (2 Replies)
Discussion started by: jim mcnamara
2 Replies

4. UNIX for Dummies Questions & Answers

How to change ethernet cable of iscsi initiator (iscsi client)?

how to change ethernet cable of iscsi initiator (iscsi client) (0 Replies)
Discussion started by: pankajd
0 Replies

5. AIX

Any tips to grow iSCSI LUN

Hi, I have an iSCSI LUN attached to an AIX 5.3 box. It's initial size is 250GB, I just grew it on the SAN to 300GB, but AIX is not seeing the change. Right now I have some processes going and it's eating up the disk space. I need to grow this lun by atleast 30GB otherwise the process with bomb... (5 Replies)
Discussion started by: bbbngowc
5 Replies

6. AIX

Netapp iscsi lun

Hi, I have aix 6.1 box. I want to configure iscsi luns from netapp storage. I tried in google but not getting proper solution for that. i m not getting the proper iqn name. Please share me the steps to complete this requirements. Thanks in advance. (1 Reply)
Discussion started by: sunnybee
1 Replies

7. Red Hat

DM multipath :iscsi lun shows by diff names on two server where its exported

Hi, I am trying to setup multipathing (using DM multipath) for a redhat cluster setup ...all setup is done but issue is : node 1 shows the shared iscsi lun as sdc node 2 shows the same as sdg (changes on reboots) Due to this (i guess) i get i/o error & i can not read files created by... (0 Replies)
Discussion started by: heman96
0 Replies

8. Solaris

Make an iSCSI LUN clone bootable

trying to do this for a DR situation. I've cloned an iSCSI LUN to another server. I've created an LDOM on it. set the LDOM to auto-boot=false and exported the LUN as a raw disk to the new LDOM. After starting the LDOM and telnetting to it. I can get to the OK prompt and see the disk but when I try... (2 Replies)
Discussion started by: os2mac
2 Replies

9. AIX

Help growing fs

Hello, I have a filesystem that I'm trying to grow but it's giving me the error: 0516-404 allocp: This system cannot fulfill the allocation request. There are not enough free partitions or not enough physical volumes to keep strictness and satisfy allocation requests. The... (5 Replies)
Discussion started by: bbbngowc
5 Replies
TARGETS(5)						      BSD File Formats Manual							TARGETS(5)

NAME
targets -- configuration file for iSCSI targets SYNOPSIS
targets DESCRIPTION
The targets file describes the iSCSI storage which is presented to iSCSI initiators by the iscsi-target(8) service. A description of the iSCSI protocol can be found in Internet Small Computer Systems Interface RFC 3720. Each line in the file (other than comment lines that begin with a '#') specifies an extent, a device (made up of extents or other devices), or a target to present to the initiator. Each definition, an extent, a device, and a target, is specified on a single whitespace delimited line. The extent definition specifies a piece of storage that will be used as storage, and presented to initiators. It is the basic definition for an iSCSI target. Each target must contain at least one extent definition. The first field in the definition is the extent name, which must begin with the word ``extent'' and be followed by a number. The next field is the file or NetBSD device which will be used as persistent storage. The next field is the offset (in bytes) of the start of the extent. This field is usually 0. The fourth field in the definition is the size of the extent. The basic unit is bytes, and the shorthand KB, MB, GB, and TB can be used for kilobytes (1024 bytes), megabytes (1024 kilobytes), gigabytes (1024 megabytes), and terabytes (1024 gigabytes) respectively. It is possible to use the word ``size'' to use the full size of the pre-existing regular file given in the extent name. The device definition specifies a LUN or device, and is made up of extents and other devices. It is possible to create hierarchies of devices using the device definition. The first field in the definition is the device name, which must begin with the word ``device'' and be followed by a number. The next field is the type of resilience that is to be provided by the device. For simple devices, RAID0 suffices. Greater resilience can be gained by using the RAID1 resilience field. Following the resilience field is a list of extents or other devices. Large devices can be created by using multiple RAID0 extents, in which case each extent will be concatenated. Resilient devices can be cre- ated by using multiple RAID1 devices or extents, in which case data will be written to each of the devices or extents in turn. If RAID1 resilience is used, all the extents or sub-devices must be the same size. Please note that RAID1 recovery is not yet supported by the iscsi-target(8) utility. An extent or sub-device may only be used once. The target definition specifies an iSCSI target, which is presented to the iSCSI initiator. Multiple targets can be specified. The first field in the definition is the target name, which must begin with either of the words ``target'' or ``lun'' and be followed by a number. Optionally, if a target is followed by an ``='' sign and some text, the text is taken to be that of the iSCSI Qualified Name of the target. This IQN is used by the initiator to connect to the appropriate target. The next field is a selector for whether the storage should be pre- sented as writable, or merely as read-only storage. The field of ``rw'' denotes read-write storage, whilst ``ro'' denotes read-only storage. The next field is the device or extent name that will be used as persistent storage for this target. The fourth field is a slash-notation netmask which will be used, during the discovery phase, to control the network addresses to which targets will be presented. The magic val- ues ``any'' and ``all'' will expand to be the same as ``0/0''. If an attempt is made to discover a target which is not allowed by the net- mask, a warning will be issued using syslog(3) to make administrators aware of this attempt. The administrator can still use tcp wrapper functionality, as found in hosts_access(5) and hosts.deny(5) to allow or deny discovery attempts from initiators as well as using the inbuilt netmask functionality. FILES
/etc/iscsi/targets the list of exported storage targets SEE ALSO
syslog(3), hosts.deny(5), hosts_access(5), iscsi-target(8) HISTORY
The targets file first appeared in NetBSD 4.0. BSD