Evening,

I am attempting to change the speed and duplex settings on a single interface on a bge card on an m3000 SPARC server. Currently the settings are as follows:

Code:
bge0            link: up        speed: 1000  Mbps       duplex: full
bge1            link: up        speed: 100   Mbps       duplex: half
bge2            link: up        speed: 1000  Mbps       duplex: full
bge3            link: unknown   speed: 0     Mbps       duplex: unknown
nxge0           link: down      speed: 1000  Mbps       duplex: full
nxge1           link: up        speed: 100   Mbps       duplex: full
nxge2           link: up        speed: 1000  Mbps       duplex: full
nxge3           link: down      speed: 1000  Mbps       duplex: full

I would like to change the bge1 interface to full duplex permanently. I read that I could make changes to the /platform/sun4u/kernel/drv/bge.conf file to make this permanent, however all of our attempts have not yielded the expected results.

Additional Information:

Code:
root@dssbfw101a.myhughesnet.com$ grep bge /etc/path_to_inst
"/pci@0,600000/pci@0/pci@1/pci@0/network@4" 0 "bge"
"/pci@0,600000/pci@0/pci@1/pci@0/network@4,1" 1 "bge"
"/pci@0,600000/pci@0/pci@2/pci@0/network@4" 2 "bge"
"/pci@0,600000/pci@0/pci@2/pci@0/network@4,1" 3 "bge"

Any assistance would be greatly appreciated.

Last edited by DukeNuke2; 08-31-2009 at 04:37 PM..
 

10 More Discussions You Might Find Interesting

1. Solaris

Duplex Settings

Hi All I've been having a lot of errors logged on the Cisco Catalyst (4000 series) which one of my Solaris servers is patched into. I have a feeling they are duplex related, but I'm a bit stuck as to how to confirm that. How do I: 1. Check the duplex settings on my eri0 card? 2. Set the... (3 Replies)
Discussion started by: saabir
3 Replies

2. IP Networking

NIC speed 100M/full duplex problem

I have a TOSHIBA AS7000 B150 Sun Box I wanted to run it with 100M/full duplex I had added this to the /etc/system file to make to setting permenant So it would be set correctly on reboot. set eri:eri_adv_100fdx_cap=1 set eri:eri_adv_100hdx_cap=0 set eri:eri_adv_autoneg_cap=0 But when I... (4 Replies)
Discussion started by: AirWalker83
4 Replies

3. HP-UX

command to change duplex settings..

Hi Folks, I want the command to change the duplex settings of a HP-UX server. Thanks in advance. Sagar. (2 Replies)
Discussion started by: sag71155
2 Replies

4. Solaris

gigabit - fix speed/duplex on the switch ? or autoneg ?

Hi there We have a bit of a debate going here over what the prefered method is for setting 1000/Full on e1000g or nge interfaces is. As you aware the Solaris configration files for nge and e1000g dont allow you to "fix" 1000/Full but instead allow you to set auto-negotiate to ON but only... (1 Reply)
Discussion started by: hcclnoodles
1 Replies

5. UNIX for Advanced & Expert Users

How to set full duplex for solaris 5.5

I would like to change half duplex to full duplex on solaris 5.5. I tried with below commands but they didnt work on solaris 5.5. #ndd -set /dev/le adv_100fdx_cap 1 (6 Replies)
Discussion started by: csreenivas
6 Replies

6. Infrastructure Monitoring

How to find the duplex speed on Windows

Hi, In UNIX, it's very easy to find the duplex speed. But in Windows, is there a easy way to find the duplex speed? I can't go to over 100 servers to find this out, I was wondering if I run one command to do this? Please advice. (2 Replies)
Discussion started by: samnyc
2 Replies

7. Solaris

How to find half duplex or full duplex

Hi, How to find whether the server is running with half duplex or full duplex. I tried with the following command ndd -get /dev/ but am not getting any output,. Is the command correct? Also let me know how to change from half to full duplex. (1 Reply)
Discussion started by: rogerben
1 Replies

8. AIX

How to change Speed Duplex

How to change Speed Duplex ! How to change Speed Duplex by command chdev -P -l ent1 -a media_speed=1000_Full_Duplex How to change Speed Duplex by Smitty . smitty chgenet -> select adapter -> change Media speed etc. -> set "Apply change to DATABASE only" to yes -> Enter -> ... (0 Replies)
Discussion started by: ITHelper
0 Replies

9. AIX

Connected and Running with half duplex speed

VIO Server connected to switch port and running with half duplex speed on one of the shared ethernet adapter. We have verified at switch end and everythings looks good. Other ethernet adapter in the VIO server are connected and running in Full duplex speed. Please help me find why this shared... (4 Replies)
Discussion started by: mugunthanvh
4 Replies

10. Shell Programming and Scripting

Need script help for monitoring duplex settings

So I have a server I am trying to set up a script to send a Wall message notifying of my eth0 nic being set to 100 half duplex instead of 100 full duplex. I know I am trying to read from /etc/sysconfig/network/ifcfg-eth0 to pull the parameters STARTMODE=onboot BOOTPROTO=static... (6 Replies)
Discussion started by: lutador72
6 Replies
dmfe(7D)							      Devices								  dmfe(7D)

NAME
dmfe - Davicom Fast Ethernet driver for Davicom DM9102A SYNOPSIS
/platform/sun4u/kernel/drv/sparcv9/dmfe DESCRIPTION
The dmfe Ethernet device provides 100Base-TX networking interfaces using the Davicom DM9102A chip, which incorporates its own internal transceiver. The dmfe driver is a multithreaded, loadable, clonable, GLD-based STREAMS driver. Multiple controllers installed within the system are supported by the driver. The dmfe driver functions include controller initialization, frame transmit and receive, promiscuous and multicast support, and error recovery and reporting. The 100Base-TX standard specifies an auto-negotiation protocol to automatically select the mode and speed of operation. The internal trans- ceiver is capable of performing autonegotiation with the remote-end of the link (link partner) and receives the capabilities of the remote end. It selects the highest common denominator mode of operation based on the priorities. The internal transceiver also supports a forced-mode of operation under which the driver selects the operational mode. APPLICATION PROGRAMMING INTERFACE
The /dev/dmfe cloning character-special device is used to access all Davicom DM9102A devices installed in the system. The dmfe driver is dependent on /kernel/misc/gld, a loadable kernel module that provides the dmfe driver with the DLPI and STREAMS func- tionality required of a LAN driver. See gld(7D) for more details on the primitives supported by the driver. You must send an explicit DL_ATTACH_REQ message to associate the opened stream with a particular device (ppa). The ppa ID is interpreted as an unsigned integer data type and indicates the corresponding device instance (unit) number. If the ppa field value does not correspond to a valid device instance number for this system, an error (DL_ERROR_ACK) is returned. The device is initialized on first attach and de-ini- tialized (stopped) at last detach. The values returned by the driver in the DL_INFO_ACK primitive in response to a DL_INFO_REQ are as follows: o Maximum SDU is 1500 (ETHERMTU - defined in sys/ethernet.h). o Minimum SDU is 0. o DLSAP address length is 8. o MAC type is DL_ETHER. o The sap length value is -2, meaning the physical address component is followed immediately by a 2-byte sap component within the DLSAP address. o The broadcast address value is the Ethernet/IEEE broadcast address (FF:FF:FF:FF:FF:FF). Once in the DL_ATTACHED state, you must send a DL_BIND_REQ to associate a particular Service Access Point (SAP) with the stream. CONFIGURATION
By default, the dmfe driver performs auto-negotiation to select the speed and mode of the link. Link speed and mode can be 100 Mbps (full or half-duplex) or 10 Mbps (full or half-duplex) as described in the 100Base-TX standard. The auto-negotiation protocol automatically selects speed mode (either 100 Mbps or 10 Mbps) and operation mode (either full-duplex or half- duplex) as the highest common denominator supported by both link partners. Because the dmfe device supports all modes, this effectively selects the highest-throughput mode supported by the other device. Alternatively, you can explicitly specify the link parameters by adding entries to the dmfe driver configuration file (/platform/sun4u/ker- nel/drv/dmfe.conf). You can set the speed parameter to 10 or 100 to force dmfe devices to operate at the specified speed. Additionally, you can set the full-duplex parameter to 0 or 1 to disable or force full-duplex operation, respectively. Note that specifying either "speed" or "full-duplex" explicitly disables auto-negotiation. To enable the driver to determine the appropri- ate setting for each parameter, you should always set both parameters. If it is necessary to force either speed or duplex setting (for example, because the dmfe device is connected to an ancient device or hub that does not support auto-negotiation), both parameters should be explicitly specified to match the requirements of the external device. FILES
/dev/dmfe Character special device /platform/sun4u/kernel/drv/dmfe.conf dmfe configuration file ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |x86 | +-----------------------------+-----------------------------+ SEE ALSO
attributes(5), gld(7D), dlpi(7P), streamio(7I) Writing Device Drivers STREAMS Programming Guide Network Interfaces Programmer's Guide SunOS 5.10 23 July 2003 dmfe(7D)