Hi,

did you try to simply run cfgmgr to see if your disks are showing up?

Rgds
zxmaus
 
Test Your Knowledge in Computers #762
Difficulty: Medium
The L2 cache, and higher-level caches, are never shared between the CPU cores.
True or False?

10 More Discussions You Might Find Interesting

1. AIX

Help-----ibm Aix???

:confused: Hello everybody, I am a totel dummy when it comes to UNIX!!! Must be wondering what I am doing here right? I'm most keen on knowing about-it-all. I need help. Wanna know all about the IBM AIX. The versions, the latest. Please tell me how do I go about my search. Thanks a... (3 Replies)
Discussion started by: rtanuja
3 Replies

2. UNIX for Advanced & Expert Users

how is IBM-AIX better..?

why IBM-AIX is preferred over HP-UX ..... In what way it is better for infrastructure......? Suggestions are welcome... Suggest you read the RULES (0 Replies)
Discussion started by: bishweshwar
0 Replies

3. AIX

ibm aix L1

hello all, can anyone send me ibm aix L1 interview questions... thank u guys...jiyojith (0 Replies)
Discussion started by: jiyojith
0 Replies

4. AIX

Completed IBM AIX

Yesterday I complted IBM AIX Certification (000-223). Passed 74% (8 Replies)
Discussion started by: udayn
8 Replies

5. AIX

IBM AIX on IBM Eseries & x series server

Hi, I want to know whether IBM AIX can be installed on the IBM e series and x series server hardware? Thanks & Regards Arun (2 Replies)
Discussion started by: Arun.Kakarla
2 Replies

6. Solaris

Sunfire 490 connect to IBM SAN DS4000

Hi All Recently i plan use our company Sunfire V490 to hook up the IBM SAN Storage DS4000. But i not sure is it got any requirement to do this, is it need any extra driver, equipment??? hope can get some advice from here.. Kindly advise. Thanks all (3 Replies)
Discussion started by: SmartAntz
3 Replies

7. AIX

pwage-aix for IBM AIX servers

This is the password aging script for aix just completed. So far tested and still testing on one of our aix server running 5.3.0.0. So anyway as you can see it is very similar to pwage-hpux-T the only difference on aix /etc/passwd file looks in this format. Also for this script to work you need to... (0 Replies)
Discussion started by: sparcguy
0 Replies

8. Red Hat

IBM Connect:Direct Error

Hi to all, I've installed IBM Connect:Direct 4.1.00 on Red Hat Enterprise Linux Server release 5.5, but when I try to execute the "direct cli", I obtain the following error: $ ./direct *********************************************************** * ... (2 Replies)
Discussion started by: f.vietti
2 Replies

9. AIX

AIX Remote Connect Fail With “No more multiple IP addresses to connect” Error

We have a production server at a client site running AIX. And recently when users are trying to connect to it via telnet, it prompts "No more multiple IP addresses to connect". Can I know what does this error mean? and how to rectify this? Thanks. (2 Replies)
Discussion started by: a_sim
2 Replies

10. AIX

IBM Virtual Machine OS on intel x86 and x64? IBM AIX OS on IBM Virtual Machine?

Hi There, I have zero information and zero knowledge for IBM virtual machine except Amazon cloud and VMware ESXi (Only Linux OS available). Anyone could provide me the following answer - Can IBM VM been deploy on X86 and X64 (Intel Chip)? If answer is yes any chance to deploy AIX OS... (13 Replies)
Discussion started by: chenyung
13 Replies
vgchgid(1M)															       vgchgid(1M)

NAME
vgchgid - modify the Volume Group ID (VGID) on a given set of physical devices SYNOPSIS
PhysicalVolumePath [PhysicalVolumePath] ... DESCRIPTION
The command is designed to change the LVM Volume Group ID (VGID) on a supplied set of disks. will work with any type of storage, but it is primarily targeted at disk arrays that are able to create "snapshots" or "clones" of mirrored LUNs. accepts a set of raw physical devices and ensures that they all belong to the same volume group, before altering the VGID (see section). The same VGID is set on all the disks and it should be noted that in cases of multi-PV volume groups, all the physical volumes should be supplied in a single invocation of the command. Options recognizes the following options and arguments: PhysicalVolumePath The raw devices path name of a physical volume. Background Some storage subsystems have a feature which allows a user to split off a set of mirror copies of physical storage (termed or just as LVM splits off logical volumes with the command. As the result of the "split," the split-off devices will have the same VGID as the original disks. is needed to modify the VGID on the BCV devices. Once the VGID has been altered, the BCV disks can be imported into a new volume group by using WARNINGS
Once the VGID has been changed, the original VGID is lost until a disk device is re-mirrored with the original devices. If is used on a subset of disk devices (for example, two out of four disk devices), the two groups of disk devices would not be able to be imported into the same volume group since they have different VGIDs on them. The solution is to re-mirror all four of the disk devices and re-run on all four BCV devices at the same time, and then use to import them into the same new volume group. If a disk is newly added to an existing volume group and no subsequent LVM operations has been performed to alter the structures (in other words, operations which perform an automated vgcfgbackup(1M)); then it is possible a subsequent will fail. It will report that the disk does not belong to the volume group. This may be overcome by performing a structure changing operation on the volume group (for example, using It is the system administrator's responsibility to make sure that the devices provided in the command line are all Business Copy volumes of the existing standard physical volumes and are in the ready state and writable. Mixing the standard and BC volumes in the same volume group can cause data corruption. RETURN VALUE
returns the following values: 0 VGID was modified with no error 1 VGID was not modified EXAMPLES
An example showing how might be used: 1. The system administrator uses the following commands to create the Business Continuity (BCV or BC) copy: 1) For EMC Symmetrix disks, the commands are and 2) For XP disk array, the commands are and Three BCV disks are created. 2. Change the VGID on the BCV disks. 3. Make a new volume group using the BCV disks. This step can be skipped as the group file will be created automatically. If the file is manually created it will have different major and minor numbers (see lvm(7)). 4. Import the BCV disks into the new volume group. 5. Activate the new volume group. 6. Backup the new volume group's LVM data structure. 7. Mount the associated logical volumes. SEE ALSO
vgimport(1M), vgscan(1M), vgcfgbackup(1M). vgchgid(1M)

Featured Tech Videos

All times are GMT -4. The time now is 01:58 PM.
Unix & Linux Forums Content Copyright 1993-2020. All Rights Reserved.
Privacy Policy