Operating Systems AIX Virtual Ethernet VIO HMC LPARs Post 302322242 by filosophizer on Wednesday 3rd of June 2009 07:32:23 AM
Old 06-03-2009
Quote:
The trunk priority is not important on the LPAR but is on a dual VIO configuration. Also the access external network MUST NOT be selected on the LPAR as there is no external network to access as it is all logical!
I have removed the Trunk priority and access to external network from the LPARs... and it is working fine.

I am facing another issue.

I would like to create another Virtual Ethernet Adapter and give it a new IP - different segment and different subnet mask..

LPAR 1
My en0 ==> 172.16.101.10
G/W ==> 172.16.101.1
Subnet mask: 255.255.255.0
VLAN ID: 1
IEEE.8 = NO


For my en1 ==> 10.10.10.10
G/W -- No gateway since it is connected to the same switch as above (Cisco Switch) but this IP is going to be used between LPARs only for RAC ( Oracle Real Application Cluster )
VLAN ID: 1
IEEE.8 = NO
subnet mask: 255.255.255.252

LPAR 2

My en0 ==> 172.16.101.11
G/W ==> 172.16.101.1
Subnet mask: 255.255.255.0
VLAN ID: 1
IEEE.8 = NO


For my en1 ==> 10.10.10.11
G/W = No Gateway
VLAN ID: 1
IEEE.8 = NO
subnet mask: 255.255.255.252

MY VIO Server 1
physical Port ==> en1 ==> 172.16.101.2
G/W: 172.16.101.1
VLAN ID: 1
IEEE.8 = NO
Subnet mask: 255.255.255.0

Physical Port
virtual en3 ( mapped with en0 for external ) ==> 172.16.101.3
G/W: 172.16.101.1
VLAN ID: 1
IEEE.8 = NO
Subnet mask: 255.255.255.0

MY VIO Server 2
physical Port ==> en1 ==> 172.16.101.4
G/W: 172.16.101.1
Subnet mask: 255.255.255.0

Physical Port
virtual en3 (mapped with en0 for external) ==> 172.16.101.5
G/W: 172.16.101.1
Subnet mask: 255.255.255.0


But I cannot ping
from LPAR1 to LPAR2 on the IP 10.10.10.11

1) Do I need to add a different VLAN ID in each LPAR for 10.10.10.x SUB-NET ?

2) Do I need to add a different VLAN ID and create a virtual ethernet adapter in VIO_Server ?

3) Do I need to enable the IEEE8 ?

any help would be appreciated.
 

9 More Discussions You Might Find Interesting

1. AIX

Help urgent : vio server - add extral disk on virtual lpar

Hi, I define 2 new LV on the vio server and run a cfgmgr on the partition and see my 2 new hdisk (hdisk6 and hdisk7). I extend my vg vg000 (on the partition) and add the 2 hdisks. I had a filesystem on the vg000 and when I added the disk I would like to increase the filesystem. But I cannot do a... (0 Replies)
Discussion started by: touny
0 Replies

2. UNIX for Advanced & Expert Users

Virtual Ethernet

I understand that one should setup virtual ethernet adapters in the lpars which is the best way for various lpars to communicate with each other - Does anyone have info on this or can point me to a doc that explains how to set this up? (1 Reply)
Discussion started by: capeme
1 Replies

3. AIX

Virtual Ethernet with VIO

We're using VIO (not an HMC) to manage our LPAR's We have 3 physical adapters and 4 LPARs. Through the VIO interface we assigned 2 virtual interfaces but require a 3rd interface assigned to these LPARs. I am experiencing issues understanding exactly how to create another virtual adapter, either... (1 Reply)
Discussion started by: scottsl
1 Replies

4. AIX

CDROM Issue on LPAR HMC VIO

Whenever I assign/unassign a CDROM ( RAID CTRL ) to Active LPAR from HMC, I have to reboot the LPAR. How can I do it without rebooting the LPARS. POWER6 with HMC LPARS = AIX 6.1 Any info developerWorks : AIX and UNIX : PowerVM Forum : Moving CD-ROM/DVD-ROM dynamically ... But... (5 Replies)
Discussion started by: filosophizer
5 Replies

5. AIX

Inherited VIO server an LPARs

Lucky me, someone has installed a server and got it running with the best intentions, but leaving me a headache. :wall: We have a simple p520 with 4 disks. 2x145Gb & 2x300Gb. The smaller disk pair have been built into a VIO mirrored rootvg, and quite right too. The other two disks form a... (3 Replies)
Discussion started by: rbatte1
3 Replies

6. AIX

Setting up an Integrated Virtual Ethernet adapter

All I am trying allocate an IVE to an LPAR (not a VIO) running AIX 7.1. I am getting the error: HSCL068A Explanation Logical port can not be assigned to Logical Partition because this Logical Partition is not the promiscuous LPAR for the physical port. Has anyone encountered this... (1 Reply)
Discussion started by: johnf
1 Replies

7. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

8. AIX

Connecting system to Virtual HMC

Hi, I just successfully build a Virtual Machine in virtual box with Perfectly running HMC v7. I have a IBM eServer pSeries Model 630 Model 6C4 (Power 4) i.e. 7024-6C4. I am not able to have it connect to the HMC console on the Virtual Box. Can anyone help me on how to connect it to the... (8 Replies)
Discussion started by: uzair_rock
8 Replies

9. AIX

Need to replace a broken PV in a VIO VG used for client LPARs (and it won't release the old one)

I have a broken PV in a VIO VG that's used to support client LPARs using LVs. On the client LPAR, I reduced all PVs from the relevant client VG and thus deleted it. I.e. there is no client LPAR using the VIO VG. Yet when I try to reducevg the VIO VG, it complains that the LV hosted on the PV is... (2 Replies)
Discussion started by: maraixadm
2 Replies
netmasks(4)							   File Formats 						       netmasks(4)

NAME
netmasks - network mask database SYNOPSIS
/etc/inet/netmasks /etc/netmasks DESCRIPTION
The netmasks file contains network masks used to implement IP subnetting. It supports both standard subnetting as specified in RFC-950 and variable length subnetting as specified in RFC-1519. When using standard subnetting there should be a single line for each network that is subnetted in this file with the network number, any number of SPACE or TAB characters, and the network mask to use on that network. Network numbers and masks may be specified in the conventional IP `.' (dot) notation (like IP host addresses, but with zeroes for the host part). For example, 128.32.0.0 255.255.255.0 can be used to specify that the Class B network 128.32.0.0 should have eight bits of subnet field and eight bits of host field, in addition to the standard sixteen bits in the network field. When using variable length subnetting, the format is identical. However, there should be a line for each subnet with the first field being the subnet and the second field being the netmask that applies to that subnet. The users of the database, such as ifconfig(1M), perform a lookup to find the longest possible matching mask. It is possible to combine the RFC-950 and RFC-1519 form of subnet masks in the net- masks file. For example, 128.32.0.0 255.255.255.0 128.32.27.0 255.255.255.240 128.32.27.16 255.255.255.240 128.32.27.32 255.255.255.240 128.32.27.48 255.255.255.240 128.32.27.64 255.255.255.240 128.32.27.80 255.255.255.240 128.32.27.96 255.255.255.240 128.32.27.112 255.255.255.240 128.32.27.128 255.255.255.240 128.32.27.144 255.255.255.240 128.32.27.160 255.255.255.240 128.32.27.176 255.255.255.240 128.32.27.192 255.255.255.240 128.32.27.208 255.255.255.240 128.32.27.224 255.255.255.240 128.32.27.240 255.255.255.240 128.32.64.0 255.255.255.192 can be used to specify different netmasks in different parts of the 128.32.0.0 Class B network number. Addresses 128.32.27.0 through 128.32.27.255 have a subnet mask with 28 bits in the combined network and subnet fields (often referred to as the subnet field) and 4 bits in the host field. Furthermore, addresses 128.32.64.0 through 128.32.64.63 have a 26 bits in the subnet field. Finally, all other addresses in the range 128.32.0.0 through 128.32.255.255 have a 24 bit subnet field. Invalid entries are ignored. SEE ALSO
ifconfig(1M), inet(7P) Postel, Jon, and Mogul, Jeff, Internet Standard Subnetting Procedure, RFC 950, Network Information Center, SRI International, Menlo Park, Calif., August 1985. V. Fuller, T. Li, J. Yu, K. Varadhan, Classless Inter-Domain Routing (CIDR): an Address Assignment and Aggregation Strategy, RFC 1519, Network Information Center, SRI International, Menlo Park, Calif., September 1993. T. Pummill, B. Manning, Variable Length Subnet Table For IPv4, RFC 1878, Network Information Center, SRI International, Menlo Park, Calif., December 1995. NOTES
/etc/inet/netmasks is the official SVr4 name of the netmasks file. The symbolic link /etc/netmasks exists for BSD compatibility. SunOS 5.10 7 Jan 1997 netmasks(4)
All times are GMT -4. The time now is 06:13 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy