07-17-2002
Try looking at the documentation on DiskSuite (the software comes with the OS). See
Solstice DiskSuite User Guide.
It has step by step instructions on how to set it up and you can then set up a stripe across the two drives, mirror, or concatenate.
(I was going to answer about an hour ago when my system crashed - hardware has been flaky after a power hit - someone forgot to recharge the batteries in the UPS)
9 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
I have just started getting into unix and aquired a Sun Ultra 5 however the disk failed and I want to replace it with a spare maxtor 40Gb i have lying around. I need to partition and format the disk from its old windows format. I have looked up info on the format command in solaris 9 and I think i... (2 Replies)
Discussion started by: kalm
2 Replies
2. Solaris
Hai ......... my name Rio,
I want to clone my harddisk at Sun Balade 2000 server with Solaris 8 OS, my question is :
a. what kind method for making backup or clonning disk ?
b. what method more easier , quick but still reliable ?
c. how to proceed it ?
Thanks (1 Reply)
Discussion started by: rioria
1 Replies
3. UNIX for Advanced & Expert Users
Dear Sun gurus,
I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies
4. Solaris
It's me again, I was taking my Sun Blade 100 apart last night to see what kind of drive I have. It is a Seagate ST320011A Barracuda ATA IV 20 GB 7200 RPM Ultra ATA/100 IDE.
Now 20 gig ain't all that big anymore and I got to thinking about putting a couple bigger drives in there. although I... (7 Replies)
Discussion started by: BrewDudeBob
7 Replies
5. Solaris
HI guys.
Bit of a noob so bear with me.
I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was... (4 Replies)
Discussion started by: jamie_collins
4 Replies
6. Emergency UNIX and Linux Support
we have a SUN M3000 server.
setup as only 1 domain.
disk c0t0d0 and c0t1d0 and setup as SVM mirrors.
a few days ago disk T1 failed.
new we have replaced the disk, but can's see the disk in format.
have done cfgadm and devfsadm.
still can't access the new disk in format.
the output... (6 Replies)
Discussion started by: robsonde
6 Replies
7. Solaris
We have hardware RAID configured on Sun-Blade-T6320 and one of the disk got failed. Hence we replaced the failed disk. But the hot swapped disk not recognized by RAID. Kindly help on fixing this issue.
We have 2 LDOM configured on this server and this server running on single disk.
#... (8 Replies)
Discussion started by: rock123
8 Replies
8. Solaris
Hi,
Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great.
# uname –a
SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4
#df -k
Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies
9. Solaris
Hi,
I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is
Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken.
Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies
LEARN ABOUT OSF1
volreattach
volreattach(8) System Manager's Manual volreattach(8)
NAME
volreattach - Reattaches disk drives that have once again become accessible
SYNOPSIS
/usr/sbin/volreattach [-rb] [accessname...]
/usr/sbin/volreattach -c accessname
OPTIONS
The volreattach utility has the following options: Calls the volrecover utility to attempt to recover stale plexes of any volumes on the
failed disk. Performs the reattach operation in the background. Checks whether a reattach is possible. No operation is performed, but the
name of the disk group and disk media name at which the disk can be reattached is displayed.
DESCRIPTION
The volreattach utility attempts to reattach disks using the same disk group and media names they had before detachment.
This operation may be necessary if a disk has a transient failure, or if some disk drivers are unloaded or unloadable when the Logical
Storage Manager is started, causing disks to enter the failed state.
If the problem is fixed, the volreattach command can be used to reattach the disks without plexes being flagged as stale, as long as the
reattach happens before any volumes on the disk are started.
The volreattach command is called from the voldiskadm menus as part of disk recovery.
The volreattach utility tries to find a disk with a disk group and disk ID matching that of the disk(s) being reattached. If the matching
disk is found, the reattach operation may still fail if the original cause (or some other cause) for the disk failure still exists.
EXIT CODES
A zero exit status is returned if it is possible to perform a reattach. Otherwise, non-zero is returned.
SEE ALSO
volintro(8), voldiskadm(8), volrecover(8)
volreattach(8)