Thread Thread Starter Forum Replies Last Post
POWER6 VIO Failover filosophizer AIX 17 05-30-2009 03:59 AM
LAMP Server Failover Ikon UNIX for Advanced & Expert Users 3 08-08-2008 01:58 PM
failover on 4.5 hacmp itik AIX 2 06-25-2008 05:04 AM
directories failover prvnrk UNIX for Advanced & Expert Users 3 04-20-2008 03:46 PM
Interfaces do not failover StorageGuy SUN Solaris 5 08-06-2005 06:39 PM

Reply
English Japanese Spanish French German Portuguese Italian Dutch Swedish Russian Norwegian Hungarian Hebrew Danish Powered by Powered by Google
 
LinkBack Thread Tools Search this Thread Rate Thread Display Modes
  #1 (permalink)  
Old 3 Weeks Ago
glenioborges glenioborges is offline
Registered User
  
 

Join Date: Oct 2009
Posts: 3
EMC Failover

Hi guys,

I'm running vxdmp and powerpath at the same time. Vxdmp for internal disks and powerpath for external.

The problem is that, on the failover tests which a fiber cable should be removed, the system cannot recognize the disks.

Any hints on how to configure powerpath in order to correctly handle the failover?

Thank you
  #2 (permalink)  
Old 3 Weeks Ago
System Shock's Avatar
System Shock System Shock is offline Forum Advisor  
Registered User
  
 

Join Date: May 2006
Location: Tau Ceti V
Posts: 521
What do you mean by "the system cannot recognize the disks"? Do you mean the OS loses visibility to the data in the SAN? Disconnecting the fiber cable should not prevent the OS from recognizing the volume presented by Powerpath.

What's the output of
Code:
powermt display dev=all
  #3 (permalink)  
Old 3 Weeks Ago
glenioborges glenioborges is offline
Registered User
  
 

Join Date: Oct 2009
Posts: 3
powermt display

Thank you for replying.

What I mean is that after removing one cable, command like "format" and "vxdisk -o alldgs list", keep searching for disks and don't show any.

Here is the "powermt display" output, in a normal situation (with the 2 FC connected)

Code:
# powermt display dev=all
Pseudo name=emcpower2a
CLARiiON ID=CKM00092300238 [MECO_MMAIN]
Logical device ID=6006016058C022002E52A213DAB4DE11 [FMM]
state=alive; policy=BasicFailover; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B       Array failover mode: 4
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
###  HW Path                I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
3074 pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0/fp@0,0 c2t500601613CE03792d1s0 SP A1     active  alive      0      0
3074 pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0/fp@0,0 c2t500601693CE03792d1s0 SP B1     active  alive      0      0
3072 pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,qlc@0/fp@0,0 c3t500601603CE03792d1s0 SP A0     unlic   alive      0      0
3072 pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,qlc@0/fp@0,0 c3t500601683CE03792d1s0 SP B0     unlic   alive      0      0
Pseudo name=emcpower1a
CLARiiON ID=CKM00092300238 [MECO_MMAIN]
Logical device ID=6006016058C02200460681D6DAB4DE11 [DATAFILES]
state=alive; policy=BasicFailover; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A       Array failover mode: 4
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
###  HW Path                I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
3074 pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0/fp@0,0 c2t500601613CE03792d2s0 SP A1     active  alive      0      0
3074 pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0/fp@0,0 c2t500601693CE03792d2s0 SP B1     active  alive      0      0
3072 pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,qlc@0/fp@0,0 c3t500601603CE03792d2s0 SP A0     unlic   alive      0      0
3072 pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,qlc@0/fp@0,0 c3t500601683CE03792d2s0 SP B0     unlic   alive      0      0
Pseudo name=emcpower3a
CLARiiON ID=CKM00092300238 [MECO_MMAIN]
Logical device ID=6006016058C022006E6BCACED9B4DE11 [ORACLE]
state=alive; policy=BasicFailover; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B       Array failover mode: 4
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
###  HW Path                I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
3074 pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0/fp@0,0 c2t500601613CE03792d0s0 SP A1     active  alive      0      0
3074 pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0/fp@0,0 c2t500601693CE03792d0s0 SP B1     active  alive      0      0
3072 pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,qlc@0/fp@0,0 c3t500601603CE03792d0s0 SP A0     unlic   alive      0      0
3072 pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,qlc@0/fp@0,0 c3t500601683CE03792d0s0 SP B0     unlic   alive      0      0
Pseudo name=emcpower0a
CLARiiON ID=CKM00092300238 [MECO_MMAIN]
Logical device ID=6006016058C0220080DD3656DAB4DE11 [BGW]
state=alive; policy=BasicFailover; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A       Array failover mode: 4
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
###  HW Path                I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
3074 pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0/fp@0,0 c2t500601613CE03792d3s0 SP A1     active  alive      0      0
3074 pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0/fp@0,0 c2t500601693CE03792d3s0 SP B1     active  alive      0      0
3072 pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,qlc@0/fp@0,0 c3t500601603CE03792d3s0 SP A0     unlic   alive      0      0
3072 pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,qlc@0/fp@0,0 c3t500601683CE03792d3s0 SP B0     unlic   alive      0      0
Please use code tags...(VBE)

Last edited by vbe; 3 Weeks Ago at 02:18 PM.. Reason: code tags added
  #4 (permalink)  
Old 3 Weeks Ago
System Shock's Avatar
System Shock System Shock is offline Forum Advisor  
Registered User
  
 

Join Date: May 2006
Location: Tau Ceti V
Posts: 521
According to this output, you don't have a license. Do you have a license for Powerpath? Have you installed the license with emcpreg ?
  #5 (permalink)  
Old 3 Weeks Ago
glenioborges glenioborges is offline
Registered User
  
 

Join Date: Oct 2009
Posts: 3
Veritas command

Thank you for replying.

You right, I didn't apply the correct license. But this couldn't solve the problem.

But I found a way to disable the dmp feature that was handling the storage at the same time as powerpath. Using the following commands:

# vxddladm settune monitor_fabric=off
# vxdmpadm settune dmp_probe_idle_lun=off


Cheers
Reply

Bookmarks

Tags
emc failover

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On




All times are GMT -4. The time now is 06:31 AM.


Powered by: vBulletin, Copyright ©2000 - 2006, Jelsoft Enterprises Limited. Language Translations Powered by .
vBCredits v1.4 Copyright ©2007 - 2008, PixelFX Studios
The UNIX and Linux Forums Content Copyright ©1993-2009. All Rights Reserved.Ad Management by RedTyger

Content Relevant URLs by vBSEO 3.2.0