Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

smp_read_gpio(8) [suse man page]

SMP_READ_GPIO(8)						     SMP_UTILS							  SMP_READ_GPIO(8)

NAME
smp_read_gpio - invoke READ GPIO REGISTER SMP function SYNOPSIS
smp_read_gpio [--count=CO] [--help] [--hex] [--index=IN] [--interface=PARAMS] [--raw] [--sa=SAS_ADDR] [--type=TY] [--verbose] [--version] SMP_DEVICE[,N] DESCRIPTION
Sends a SAS Management Protocol (SMP) READ GPIO REGISTER request to a SMP target. The SMP target is identified by the SMP_DEVICE and the SAS_ADDR. Depending on the interface, the SAS_ADDR may be deduced from the SMP_DEVICE. With one interface there is one SMP_DEVICE per machine so the SMP_DEVICE,N syntax is needed to differentiate between HBAs if there are multiple present. This function is defined in SFF-8485 ( see www.sffcommittee.com ) together with its corresponding WRITE GPIO REGISTER SMP function. The other SMP functions are defined in SAS documents at www.t10.org . SFF-8485 defines a curious device called a "virtual SMP port" that lives in a host bus adapter (HBA) and allows SMP to manipulate the sideband signals on wide internal cables. To stop other initiators in a multi-initiator domain from accessing those sideband signals, the virtual SMP (target) port is not indicated in a DISCOVER response. OPTIONS
Mandatory arguments to long options are mandatory for short options as well. -c, --count=CO where CO is the register count. This is the number of (4 byte) registers to request. The default value is 1. -h, --help output the usage message then exit. -H, --hex output the response in hexadecimal. -i, --index=IN where IN is the register index. This value is origin zero and its default value is 0. If the request succeeds, then --count=CO reg- isters starting from --index=IN of the given --type=TY should be in the response. -I, --interface=PARAMS interface specific parameters. In this case "interface" refers to the path through the operating system to the SMP initiator. See the smp_utils man page for more information. -r, --raw send the response to stdout in binary. All error messages are sent to stderr. -s, --sa=SAS_ADDR specifies the SAS address of the SMP target device. Typically this is an expander. This option may not be needed if the SMP_DEVICE has the target's SAS address within it. The SAS_ADDR is in decimal but most SAS addresses are shown in hexadecimal. To give a number in hexadecimal either prefix it with '0x' or put a trailing 'h' on it. -t, --type=TY where TY is the register type. The default value is 0 (GPIO_CFG). If the request succeeds, then --count=CO registers starting from --index=IN of the given --type=TY should be in the response. -v, --verbose increase the verbosity of the output. Can be used multiple times -V, --version print the version string and then exit. CONFORMING TO
The SMP READ GPIO REGISTER function is defined in SFF-8485 (see www.sffcommittee.com ) together with its corresponding WRITE GPIO REGISTER SMP function. AUTHORS
Written by Douglas Gilbert. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2006-2008 Douglas Gilbert This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
smp_utils, smp_write_gpio(smp_utils) smp_utils-0.93 January 2008 SMP_READ_GPIO(8)

Check Out this Related Man Page

SMP_REP_MANUFACTURER(8) 					     SMP_UTILS						   SMP_REP_MANUFACTURER(8)

NAME
smp_rep_manufacturer - invoke REPORT MANUFACTURER INFORMATION SMP function SYNOPSIS
smp_rep_manufacturer [--help] [--hex] [--interface=PARAMS] [--raw] [--sa=SAS_ADDR] [--verbose] [--version] SMP_DEVICE[,N] DESCRIPTION
Sends a SAS Management Protocol (SMP) REPORT MANUFACTURER INFORMATION request function to a SMP target. The SMP target is identified by the SMP_DEVICE and the SAS_ADDR. Depending on the interface, the SAS_ADDR may be deduced from the SMP_DEVICE. With one interface there is one SMP_DEVICE per machine so the SMP_DEVICE,N syntax is needed to differentiate between HBAs if there are multiple present. OPTIONS
Mandatory arguments to long options are mandatory for short options as well. -h, --help output the usage message then exit. -H, --hex output the response in hexadecimal. -I, --interface=PARAMS interface specific parameters. In this case "interface" refers to the path through the operating system to the SMP initiator. See the smp_utils man page for more information. -r, --raw send the response to stdout in binary. All error messages are sent to stderr. -s, --sa=SAS_ADDR specifies the SAS address of the SMP target device. Typically this is an expander. This option may not be needed if the SMP_DEVICE has the target's SAS address within it. The SAS_ADDR is in decimal but most SAS addresses are shown in hexadecimal. To give a number in hexadecimal either prefix it with '0x' or put a trailing 'h' on it. -v, --verbose increase the verbosity of the output. Can be used multiple times -V, --version print the version string and then exit. CONFORMING TO
The SMP REPORT MANUFACTURER function was introduced in SAS-1, with small additions in SAS-1.1 . AUTHORS
Written by Douglas Gilbert. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2006-2008 Douglas Gilbert This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
smp_utils, smp_discover(smp_utils) smp_utils-0.93 January 2008 SMP_REP_MANUFACTURER(8)