Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

ds2409(3) [debian man page]

DS2409(3)						       One-Wire File System							 DS2409(3)

NAME
DS2409 - MicroLAN Coupler SYNOPSIS
1-wire network branch controller. 1F [.]XXXXXXXXXXXX[XX][/[ aux | branch.[0|1|ALL|BYTE] | control | discharge | event.[0|1|ALL|BYTE] | clearevent | main | sensed.[0|1|ALL|BYTE] | address | crc8 | id | locator | r_address | r_id | r_locator | type ]] FAMILY CODE
1F SPECIAL PROPERTIES
aux directory This is the aux branch of the DS2409 network branch. It is implicitly accessed (via the aux smart-on command) when it is listed or devices on this branch are addressed. branch.0 branch.1 branch.ALL branch.BYTE read-only, yes-no Is the branch ( 0=main or 1=aux ) currently connected to the master bus? Value returned is 1 (yes) or 0 (no). The DS2409 should not allow both to be on simultaneously. ALL is an aggregate of the properties, comma separated. It is an atomic operation. BYTE is an aggregate of the branches as a byte, A is bit 0. control read-write, unsigned integer Setting of the PIO control pin. There are 4 possible settings: 0 Unconditionally off (non-conducting) 1 Unconditionally on (conducting) 2 Auto on when main branch switched in 3 Auto on when aux branch switched in discharge write-only, yes-no Writing a non-zero value to this property will electrically reset both the main and auxillary branches of the 1-wire bus by dropping power for 100 milliseconds. All devices on those branches will lose parasitic power and reset to power-up defaults. As a side effect, both event flags and thus, the alarm state, are cleared, too. event.0 event.1 event.ALL event.BYTE read-only, yes-no Has the event flag for the branch been triggered? A negative edge on the disconnected branch ( 0=main or 1=aux ) sets the flag. This is achieved by e.g. connecting an iButton to the branch. Value returned is 1 (yes) or 0 (no). ALL is an aggregate of the properties, comma separated. It is an atomic operation. BYTE is an aggregate of the branches as a byte, main is bit 0. clearevent write-only, yes-no Writing a non-zero value to this property will reset both event flags and thus, clear the alarm state, too. main directory This is the main branch of the DS2409 network branch. It is implicitly accessed (via the main smart-on command) when it is listed or devices on this branch are addressed. sensed.0 sensed.1 sensed.ALL sensed.BYTE read-only, yes-no Voltage sensed at the 0=main or 1=aux branch pin. Valid only when the branch is switched out. Value returned is 0 (low) or 1 (high). ALL is an aggregate of the properties, comma separated. It is an atomic operation. BYTE is an aggregate of the branches as a byte, A is bit 0. STANDARD PROPERTIES
address r_address read-only, ascii The entire 64-bit unique ID. Given as upper case hexidecimal digits (0-9A-F). address starts with the family code r address is the address in reverse order, which is often used in other applications and labeling. crc8 read-only, ascii The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of the unique ID number. Given as upper case hexidecimal digits (0-9A-F). family read-only, ascii The 8-bit family code. Unique to each type of device. Given as upper case hexidecimal digits (0-9A-F). id r_id read-only, ascii The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as upper case hexidecimal digits (0-9A- F). r id is the id in reverse order, which is often used in other applications and labeling. locator r_locator read-only, ascii Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical connections with a unique 1-wire code. If the connection is behind a Link Locator the locator will show a unique 8-byte number (16 character hexidecimal) starting with family code FE. If no Link Locator is between the device and the master, the locator field will be all FF. r locator is the locator in reverse order. present (DEPRECATED) read-only, yes-no Is the device currently present on the 1-wire bus? type read-only, ascii Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton vs chip) will not be distiguished. ALARMS
The DS2409 will respond to a conditional search if the main event flag is set. DESCRIPTION
1-Wire 1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power. Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humid- ity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included. The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID. Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters. OWFS design OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying priciple is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written. Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundemental goal has been ease of use, flexibility and correctness rather than speed. DS2409 The DS2409 (3) allows complex 1-wire network topology. Each branch has it's power preserved, even when isolated from the master. A separate PIO pin can be configured to show branch switching, or controlled explicitly. ADDRESSING
All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form: Family Code 8 bits Address 48 bits CRC 8 bits Addressing under OWFS is in hexidecimal, of form: 01.123456789ABC where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address. The dot is optional, and the CRC code can included. If included, it must be correct. DATASHEET
http://pdfserv.maxim-ic.com/en/ds/DS2409.pdf SEE ALSO
Programs owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1) Configuration and testing owfs (5) owtap (1) owmon (1) Language bindings owtcl (3) owperl (3) owcapi (3) Clocks DS1427 (3) DS1904(3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3) ID DS2401 (3) DS2411 (3) DS1990A (3) Memory DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3) Switches DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) Temperature DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) Humidity DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3) Voltage DS2450 (3) Resistance DS2890 (3) Multifunction (current, voltage, temperature) DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3) Counter DS2423 (3) LCD Screen LCD (3) DS2408 (3) Crypto DS1977 (3) Pressure DS2406 (3) -- TAI8570 EDS0066 (3) EDS0068 (3) AVAILABILITY
http://www.owfs.org AUTHOR
Paul Alfille (paul.alfille@gmail.com) OWFS Manpage 2003 DS2409(3)
Man Page