Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

ds1825(3) [debian man page]

DS1825(3)						       One-Wire File System							 DS1825(3)

NAME
DS1825 - Programmable Resolution 1-Wire Digital Thermometer with ID SYNOPSIS
Thermometer with hardware address pins. 3B [.]XXXXXXXXXXXX[XX][/[ fasttemp | temperature | temperature9 | temperature10 | temperature11 | temperature12 | power | prog_addr | tem- phigh | templow | address | crc8 | id | locator | r_address | r_id | r_locator | type ]] FAMILY CODE
3B SPECIAL PROPERTIES
power read-only,yes-no Is the chip powered externally (=1) or from the parasitically from the data bus (=0)? prog_addr read-only, 0-15 A distiguishing feature of the DS1825 (3) is the ability to set hardware pins for an address (0-15). This is an alternative to the unique 64-bit address that is set in the factory. temperature read-only, floating point Measured temperature with 12 bit resolution. temperature9 temperature10 temperature11 temperature12 read-only, floating point Measured temperature at 9 to 12 bit resolution. There is a tradeoff of time versus accuracy in the temperature measurement. fasttemp read-only, floating point Equivalent to temperature9 TEMPERATURE ALARM LIMITS
When the device exceeds either temphigh or templow temperature threshold the device is in the alarm state, and will appear in the alarm directory. This provides an easy way to poll for temperatures that are unsafe, especially if simultaneous temperature conversion is done. Units for the temperature alarms are in the same temperature scale that was set for temperature measurements. Temperature thresholds are stored in non-volatile memory and persist until changed, even if power is lost. temphigh read-write, integer Shows or sets the lower limit for the high temperature alarm state. templow read-write, integer Shows or sets the upper limit for the low temperature alarm state. STANDARD PROPERTIES
address r_address read-only, ascii The entire 64-bit unique ID. Given as upper case hexidecimal digits (0-9A-F). address starts with the family code r address is the address in reverse order, which is often used in other applications and labeling. crc8 read-only, ascii The 8-bit error correction portion. Uses cyclic redundancy check. Computed from the preceding 56 bits of the unique ID number. Given as upper case hexidecimal digits (0-9A-F). family read-only, ascii The 8-bit family code. Unique to each type of device. Given as upper case hexidecimal digits (0-9A-F). id r_id read-only, ascii The 48-bit middle portion of the unique ID number. Does not include the family code or CRC. Given as upper case hexidecimal digits (0-9A- F). r id is the id in reverse order, which is often used in other applications and labeling. locator r_locator read-only, ascii Uses an extension of the 1-wire design from iButtonLink company that associated 1-wire physical connections with a unique 1-wire code. If the connection is behind a Link Locator the locator will show a unique 8-byte number (16 character hexidecimal) starting with family code FE. If no Link Locator is between the device and the master, the locator field will be all FF. r locator is the locator in reverse order. present (DEPRECATED) read-only, yes-no Is the device currently present on the 1-wire bus? type read-only, ascii Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging (iButton vs chip) will not be distiguished. DESCRIPTION
1-Wire 1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power. Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humid- ity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included. The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID. Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters. OWFS design OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying priciple is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written. Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundemental goal has been ease of use, flexibility and correctness rather than speed. DS1825 The DS1825 (3) is one of several available 1-wire temperature sensors. Alternatives are the DS18S20 (3), DS18B20 (3), and DS1822 (3) as well as temperature/voltage measurements in the DS2436 (3) and DS2438 (3). For truly versatile temperature measurements, see the protean DS1921 (3) Thermachron (3). Although the DS1825 (3) can select between 4 resolutions, this program simplifies the interface by only implementing the fastest/roughest and slowest/best. ADDRESSING
All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form: Family Code 8 bits Address 48 bits CRC 8 bits Addressing under OWFS is in hexidecimal, of form: 01.123456789ABC where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address. The dot is optional, and the CRC code can included. If included, it must be correct. DATASHEET
http://pdfserv.maxim-ic.com/en/ds/DS1825.pdf SEE ALSO
Programs owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1) Configuration and testing owfs (5) owtap (1) owmon (1) Language bindings owtcl (3) owperl (3) owcapi (3) Clocks DS1427 (3) DS1904(3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3) ID DS2401 (3) DS2411 (3) DS1990A (3) Memory DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3) Switches DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) Temperature DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) Humidity DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3) Voltage DS2450 (3) Resistance DS2890 (3) Multifunction (current, voltage, temperature) DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3) Counter DS2423 (3) LCD Screen LCD (3) DS2408 (3) Crypto DS1977 (3) Pressure DS2406 (3) -- TAI8570 EDS0066 (3) EDS0068 (3) AVAILABILITY
http://www.owfs.org AUTHOR
Paul Alfille (paul.alfille@gmail.com) OWFS Manpage 2006 DS1825(3)