Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

cmtk-groupwise_warp(1) [debian man page]

groupwise_warp(1)				       The Computational Morphometry Toolkit					 groupwise_warp(1)

NAME
groupwise_warp - Nonrigid population registration SYNOPSIS
groupwise_warp [options] affineGroupRegistration DESCRIPTION
This tool nonrigidly registers a population of input images simultaneously, without a template, using either the 'congealing' algorithm or a groupwise similarity measure based on a continuous approximation of mutual information ('RMI'). OPTIONS
Global Toolkit Options (these are shared by all CMTK tools) --help Write list of basic command line options to standard output. --help-all Write complete list of basic and advanced command line options to standard output. --wiki Write list of command line options to standard output in MediaWiki markup. --man Write man page source in 'nroff' markup to standard output. --version Write toolkit version to standard output. --echo Write the current command line to standard output. --verbose-level <integer> Set verbosity level. --verbose, -v Increment verbosity level by 1 (deprecated; supported for backward compatibility). --threads <integer> Set maximum number of parallel threads (for POSIX threads and OpenMP). Registration Metric Options --rmi Use the RMI (a.k.a. regional mutual information) metric to drive the registration). --congeal Use the congealing algorithm using pixelwise stack entropies to drive the registration. [This is the default] Template Image Options --template <string>, -t <string> Override template image with given file. [Default: NONE] --template-with-data <string>, -T <string> Use user-supplied template images's pixel data in registration [Default: disabled] Multuresolution Parameters --downsample-from <integer>, -d <integer> Initial downsampling factor [4]. [Default: 4] --downsample-to <integer>, -D <integer> Final downsampling factor [1]. [Default: 1] --sampling-density <float>, -s <float> Probabilistic sampling density [default: off]. [Default: -1] Output Options --output-root <string>, -O <string> Root directory for all output files. [Default: NONE] --output <string>, -o <string> Output filename for groupwise registration archive. [Default: groupwise.xforms ] --output-average <string> Output filename for registered average image. [Default: average.nii ] --no-output-average Do not write average image. --average-cubic Use cubic interpolation for average image (default: linear) Image Options and Operations --force-background <integer>, -B <integer> Force background pixels (outside FOV) to given (bin) value. [Default: disabled] --histogram-bins <integer>, -H <integer> Set number of histogram bins for entropy evaluation. [Default: disabled] --crop-histograms Crop image histograms to make better use of histogram bins. --match-histograms Match all image histograms to template data (or first image, if no template image is given) --repeat-match-histograms Frequetly repeat histogram-based intensity matching to account for changing volume proportions. --smooth-pixels <double> Sigma of Gaussian smoothing kernel in multiples of template image pixel size [Default: disabled] --smooth-cps <double> Sigma of Gaussian smoothing kernel in multiples of control point delta [Default: disabled] Transformation Parameters --grid-spacing <double> Control point grid spacing. [Default: 40] --grid-spacing-fit Use grid spacing that fits volume FOV --refine-grid <integer>, -r <integer> Number of times to refine transformation grid [default: 0]. [Default: 0] Transformation Constraint Options --zero-sum, -z Enforce zero-sum computation. --zero-sum-no-affine Enforce zero-sum computation EXCLUDING affine components. --normal-group-first-n <integer>, -N <integer> First N images are from the normal group and should be registered unbiased. [Default: 0] --zero-sum-first-n <integer>, -Z <integer> Enforce zero-sum computation for first N images. [Default: disabled] --jacobian-weight <float>, -J <float> Weight for Jacobian volume preservation constraint [default: off] [Default: 0] --bending-energy-weight <float>, -E <float> Weight for grid bending energy regularization constraint [default: off] [Default: 0] Optimization Parameters --exploration <double>, -e <double> Exploration of optimization in pixels [Default: 0.25] --accuracy <double>, -a <double> Accuracy of optimization in pixels [Default: 0.01] --step-factor <double>, -S <double> Step factor for successive optimization passes [Default: 0.5] --delta-f-threshold <double> Optional threshold to terminate optimization (level) if relative change of target function drops below this value. [Default: 0] --partial-gradient-thresh <float>, -p <float> Threshold factor for partial gradient zeroing [<0 turn off] [Default: 0] --activate-uninformative Activate potentially uninformative control points --disable-cp-mask <string> Path to mask image (matching template grid) defining areas in which control points should be disabled. This guarantees that mask fore- ground areas remain undeformed. [Default: NONE] --disable-optimization Disable optimization and output initial configuration. AUTHORS
Torsten Rohlfing, with contributions from Michael P. Hasak, Greg Jefferis, Calvin R. Maurer, and Daniel B. Russakoff LICENSE
http://www.fsf.org/licensing/licenses/gpl.html BUGS
Report bugs at http://nitrc.org/projects/cmtk/ ACKNOWLEDGMENTS
From April 2009 through September 2011, CMTK Development and Maintenance was supported by the National Institute of Biomedical Imaging and Bioengineering under Grant No.R01 EB008381 (PI: Torsten Rohlfing). CMTK 2.2.2 Jul 20 2012 groupwise_warp(1)
Man Page