Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

alcbanner(1) [debian man page]

ALCBANNER(1)						      ALLIANCE USER COMMANDS						      ALCBANNER(1)

NAME
alcbanner - Display a standardized banner for Alliance tools ORIGIN
This software belongs to the ALLIANCE CAD SYSTEM developed by the ASIM team at LIP6 laboratory of Universite Pierre et Marie CURIE, in Paris, France. Web : http://asim.lip6.fr/recherche/alliance/ E-mail : alliance-users@asim.lip6.fr SYNOPSIS
alcbanner tool toolversion purpose copyrightdates DESCRIPTION
alcbanner display on stdout a standardized banner for the Alliance tools. This is a compiled version of the alliancebanner(2) function. EXAMPLE
alcbanner GenPat 3.1 "Procedural GENeration of test PATterns" 1991 will display : @@@@ @ @@@@@@@ @@ @@ @@ @@ @ @@ @ @@ @@ @@ @@ @@@@@ @@@ @@@ @@ @@ @@@@ @@ @@ @ @ @@@ @ @@ @@ @@ @ @@@@@@@@ @@ @@@@@ @@ @@ @@ @@ @@@@@ @@ @@ @@ @@ @ @@ @@@@@@@@@ @@ @@ @@ @@@@@ @@ @@ @ @@ @@ @@ @@ @@ @@ @@ @@ @@ @@ @@ @ @@ @@ @@ @@ @@ @@ @@ @@ @@ @@ @@ @@ @@ @@ @@@ @@ @ @@@@ @@@@ @@@@ @@@@ @@@@@@ @@@@ @@ @@@@ Procedural GENeration of test PATterns Alliance CAD System 3.2b, genpat 3.1 Copyright (c) 1991-1997, ASIM/LIP6/UPMC E-mail : alliance-users@asim.lip6.fr SEE ALSO
mbk(1) alliancebanner(3). DIAGNOSTICS
The output is centered for a 80 columns screen, so it can be used on most display easilly, and not found at execution time. alliancebanner: Error: Resulting size bigger than 80 columns not allowed The tool argument must be such that its resulting size isn't wider that 80 culumns. This means, since the character set is propor- tional, that the longest name to be output is about 8 characters long. alliancebanner: Error: Character out of [0-9A-Za-z] range The tool parameter has a non allowed character in it. For simplicity purposes, only numbers and letters are accepted. BUG REPORT
This tool is under development at the ASIM department of the LIP6 laboratory. We need your feedback to improve documentation and tools. ASIM
/LIP6 October 1, 1997 ALCBANNER(1)

Check Out this Related Man Page

GENLIB_FLATTEN_PHFIG.3(October 1, 1997) 								   GENLIB_FLATTEN_PHFIG.3(October 1, 1997)

NAME
GENLIB_FLATTEN_PHFIG - flatten an instance in the current layout figure SYNOPSYS
#include <genlib.h> void GENLIB_FLATTEN_PHFIG(insname,concat) char *insname; char concat; ORIGIN
This software belongs to the ALLIANCE CAD SYSTEM developed by the ASIM team at LIP6 laboratory of Universite Pierre et Marie CURIE, in Paris, France. Web : http://asim.lip6.fr/recherche/alliance/ E-mail : alliance-users@asim.lip6.fr PARAMETERS
insname Name of the instance to be flattened concat Indicate whether or not to concatenate instance name to instance' objects name DESCRIPTION
FLATTEN_PHFIG inserts the contents of an instance, but its connectors, in the current figure, and then destroys the instance. The concat parameter may take two values: YES to concatenate object name with instance names. NO to copy object names. In most case, the concat value must be YES, in order to warranty the unicity of names in the figure. It may otherwise fail, because the function would try to add in the current figure some object with an already existing name. EXAMPLE
#include <genlib.h> main() { /* Create a figure to work on */ GENLIB_DEF_PHFIG("mycell"); . . . /* Place an instance */ GENLIB_PLACE("model","instance", SYM_X, 0, 0); /* flatten an instance */ GENLIB_FLATTEN_PHFIG("instance", YES); /* Save all that on disk */ GENLIB_SAVE_PHFIG(); } SEE ALSO
genlib(1), GENLIB_LOINS(3). BUG REPORT
This tool is under development at the ASIM department of the LIP6 laboratory. We need your feedback to improve documentation and tools. PROCEDURAL GENERATION LANGUAGE
ASIM/LIP6 GENLIB_FLATTEN_PHFIG.3(October 1, 1997)
Man Page