| Forums | Search Forums | Register | Forum Rules | Man Pages | Albums | FAQ | Members | Calendar | Search | Today's Posts | Mark Forums Read |
| HP-UX HP-UX (Hewlett Packard UniX) is Hewlett-Packard's proprietary implementation of the Unix operating system, based on System V. |
|
|
|
Thread Tools | Search this Thread | Display Modes |
|
#1
|
|||
|
|||
|
FAULTY DISK replacement HP rx4640
Hello, I'm new to this forum and as you will see from my question I'm new to UNIX as well. One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is the only log they sent to us. Code:
Fri May 18 17:50:11 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol1 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:50:12 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol3 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:50:12 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol4 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:50:12 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol5 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:50:12 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol6 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:50:12 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol7 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:50:12 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol8 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:50:12 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/SwapVol2 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:56:06 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol1 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:56:06 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol3 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:56:06 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol4 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:56:06 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol5 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:56:06 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol6 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:56:06 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol7 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:56:06 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/lvol8 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Fri May 18 17:56:06 2012 STCHK 122 sd_procchk sd_procchk 1 Logical volume
/dev/vg00/SwapVol2 is mirrored but has some stale blocks. Data loss on
hardware failure could occur.
Code:
# pvdisplay -v /dev/disk/disk13_p2 | grep stale 00000 stale /dev/vg00/lvol1 00000 00089 stale /dev/vg00/lvol3 00000 00090 stale /dev/vg00/lvol3 00001 00094 stale /dev/vg00/lvol3 00005 00096 stale /dev/vg00/lvol3 00007 00121 stale /dev/vg00/lvol4 00000 00122 stale /dev/vg00/lvol5 00000 00171 stale /dev/vg00/lvol5 00049 00176 stale /dev/vg00/lvol5 00054 00177 stale /dev/vg00/lvol5 00055 00183 stale /dev/vg00/lvol5 00061 00184 stale /dev/vg00/lvol5 00062 00186 stale /dev/vg00/lvol5 00064 00215 stale /dev/vg00/lvol5 00093 00219 stale /dev/vg00/lvol5 00097 00221 stale /dev/vg00/lvol5 00099 00237 stale /dev/vg00/lvol5 00115 00242 stale /dev/vg00/lvol5 00120 00279 stale /dev/vg00/lvol6 00000 00296 stale /dev/vg00/lvol7 00000 00298 stale /dev/vg00/lvol7 00002 00299 stale /dev/vg00/lvol7 00003 00306 stale /dev/vg00/lvol7 00010 00309 stale /dev/vg00/lvol7 00013 00314 stale /dev/vg00/lvol7 00018 00318 stale /dev/vg00/lvol7 00022 00326 stale /dev/vg00/lvol7 00030 00327 stale /dev/vg00/lvol7 00031 00337 stale /dev/vg00/lvol7 00041 00338 stale /dev/vg00/lvol7 00042 00340 stale /dev/vg00/lvol7 00044 00344 stale /dev/vg00/lvol7 00048 00415 stale /dev/vg00/lvol8 00000 00416 stale /dev/vg00/lvol8 00001 00417 stale /dev/vg00/lvol8 00002 00422 stale /dev/vg00/lvol8 00007 00429 stale /dev/vg00/lvol8 00014 00434 stale /dev/vg00/lvol8 00019 00437 stale /dev/vg00/lvol8 00022 00438 stale /dev/vg00/lvol8 00023 00439 stale /dev/vg00/lvol8 00024 00441 stale /dev/vg00/lvol8 00026 00445 stale /dev/vg00/lvol8 00030 00446 stale /dev/vg00/lvol8 00031 00447 stale /dev/vg00/lvol8 00032 00448 stale /dev/vg00/lvol8 00033 00449 stale /dev/vg00/lvol8 00034 00459 stale /dev/vg00/lvol8 00044 00460 stale /dev/vg00/lvol8 00045 00461 stale /dev/vg00/lvol8 00046 00462 stale /dev/vg00/lvol8 00047 00497 stale /dev/vg00/SwapVol2 00000 With my limited knowledge of UNIX i assumed from this that the disk ID is 13. If yes how do i find which of the two physical disk should be replaced? And if i identify the problematic disk, are the below steps correct? 1) Check that the disk is not in the root volume group with lvlnboot -v command 2) continue with the disk replacement: Code:
# pvchange -a N /dev/dsk/- # <replace the hot-swappable disk> # vgcfgrestore –n vg01 /dev/rdsk/- # vgchange –a y vg01 If I'm way off please inform me as i got all this from "When Good Disks Go Bad" and as i mentioned I have very little experience with UNIX. Any help is appreciated. Thanks Gjk Last edited by Scrutinizer; 05-20-2012 at 04:18 PM.. Reason: code tags |
| Sponsored Links | ||
|
|
#2
|
||||
|
||||
|
I would not touch this if I were you. Ask an experienced HP-UX admin in your company to have a look...
|
| Sponsored Links | ||
|
|
#3
|
|||
|
|||
|
That was my first thought, to not touch it. But at the moment our UNIX admin is not available and costumer is expecting a solution tonight. If there is a straight-forward procedure, for at least how to identify which physical disk is, please help. What i got so far is this command: Code:
# ioscan –m lun /dev/disk/disk13 Thanks again, Gjk Last edited by Scott; 05-23-2012 at 04:40 AM.. Reason: Code tags |
|
#4
|
||||
|
||||
|
I dont know if I can help because I have VERY little experience on RX boxes now I managed to find one for home someone removed the disks before I got hold of it...
You did not say (or Im blind...) your OS version! vg00 is usually the OS (and so root / boot disks...) even more true when you see no lvol2... for its the swap... I would suggest before going further to get 2 new disks, get them ordered you may not need them or perhaps one but if things go wrong or the situation is not cool you may be glad to have 2 with you (believe my experience...). Next once you have them try to make a recovery tape or an "Golden Image" somehow, if the system manages then you are perhaps in the way to solve your issue online, if not try to find the last bootable backup of the system (you may need it...) Lest say you managed a make_recovery, you know can go and try stm or xstm (X GUI ) and see what the tool diagnose about your disks here give us what you found, and we will do a bit of brainstorming... Good luck! |
| Sponsored Links | |
|
|
#5
|
|||
|
|||
|
Thank you for your help VBE and you are not blind but I don't know the OS version. As i have very limited access to the costumer site only tonight i will be able to find out the OS version and more about the disk. What i have confirmed is that it is a boot disk. With what i know from costumer the system is connected to msl6030 tape library and they do backups of configuration every day. Unfortunately I'm not familiar with diagnose tool but I'll try my best to get as much info as possible and post.
Thank you very very much |
| Sponsored Links | |
|
|
#6
|
||||
|
||||
|
Type Code:
vgdisplay -v vg00 | grep dsk to see what disks are in vg00 then again Code:
vgdisplay -v vg00 And look at the last stanza : You should see something like: Code:
--- Physical volumes --- PV Name /dev/dsk/c2t2d0 PV Status available Total PE 4340 Free PE 357 Autoswitch On Proactive Polling On PV Name /dev/dsk/c1t2d0 PV Status available Total PE 4340 Free PE 357 Autoswitch On Proactive Polling On Hoping it will tell you what disk is failing... or already dead e.g: Code:
# ioscan -funC disk Class I H/W Path Driver S/W State H/W Type Description =================================================================== disk 0 16/5.2.0 sdisk CLAIMED DEVICE TOSHIBA CD-ROM XM-5401TA /dev/cdrom /dev/dsk/c1t2d0 /dev/rdsk/c1t2d0 disk 1 16/5.5.0 sdisk CLAIMED DEVICE SEAGATE ST39173N /dev/dsk/c1t5d0 /dev/rdsk/c1t5d0 disk 2 16/5.6.0 sdisk NO_HW DEVICE SEAGATE ST39173N => No Hardware... /dev/dsk/c1t6d0 /dev/rdsk/c1t6d0 Also, look what you have in your /var/adm/syslog/syslog.log ! You may fins EM- critical messages... |
| Sponsored Links | |
|
|
#7
|
|||
|
|||
|
Hello, I was able last night to gather some more info about the OS and the condition of the disk. I think it needs to be replaced. As you will see from below is the alternate disk and not primary. I'm trying to scramble a procedure for replacement from "When Good Disks Go Bad" but i have some doubts about it. If you can help it will be real helpfully. Code:
# uname -a
HP-UX - B.11.31 U ia64 2801820572 unlimited-user license
# model
ia64 hp server rx4640
# ioscan -funC disk
Class I H/W Path Driver S/W State H/W Type Description
=======================================================================
disk 5 0/0/3/0.0.0.0 sdisk CLAIMED DEVICE TEAC DV-28E-N
/dev/dsk/c0t0d0 /dev/rdsk/c0t0d0
disk 0 0/1/1/0.1.0 sdisk CLAIMED DEVICE HP 146 GST3146855LC
/dev/dsk/c2t1d0 /dev/dsk/c2t1d0s2 /dev/rdsk/c2t1d0 /dev/rdsk/c2t1d0s2
/dev/dsk/c2t1d0s1 /dev/dsk/c2t1d0s3 /dev/rdsk/c2t1d0s1 /dev/rdsk/c2t1d0s3
disk 4 0/1/1/1.0.0 sdisk NO_HW DEVICE HP 146 GST3146855LC
/dev/dsk/c3t0d0 /dev/dsk/c3t0d0s2 /dev/rdsk/c3t0d0 /dev/rdsk/c3t0d0s2
/dev/dsk/c3t0d0s1 /dev/dsk/c3t0d0s3 /dev/rdsk/c3t0d0s1 /dev/rdsk/c3t0d0s3
# lvlnboot -v
Boot Definitions for Volume Group /dev/vg00:
Physical Volumes belonging in Root Volume Group:
/dev/disk/disk9_p2 -- Boot Disk
/dev/disk/disk13_p2
Boot: lvol1 on: /dev/disk/disk9_p2
/dev/disk/disk13_p2
Root: lvol3 on: /dev/disk/disk9_p2
/dev/disk/disk13_p2
Swap: lvol2 on: /dev/disk/disk9_p2
/dev/disk/disk13_p2
Dump: lvol2 on: /dev/disk/disk9_p2, 0
# pvdisplay –v /dev/dsk/c3t0d0 | more
# lvdisplay –v /dev/vg00/lvol1 | grep “Mirror copies”
Mirror copies 1
# lvdisplay –v /dev/vg00/lvol2 | grep “Mirror copies”
Mirror copies 1
# lvdisplay –v /dev/vg00/lvol3 | grep “Mirror copies”
Mirror copies 1
# lvdisplay –v /dev/vg00/lvol4 | grep “Mirror copies”
Mirror copies 1
# lvdisplay –v /dev/vg00/lvol5 | grep “Mirror copies”
Mirror copies 1
# lvdisplay –v /dev/vg00/lvol6 | grep “Mirror copies”
Mirror copies 1
# lvdisplay –v /dev/vg00/lvol7 | grep “Mirror copies”
Mirror copies 1
# lvdisplay –v /dev/vg00/lvol8 | grep “Mirror copies”
Mirror copies
1
# vgdisplay -v /dev/vg00
--- Volume groups ---
VG Name /dev/vg00
VG Write Access read/write
VG Status available
Max LV 255
Cur LV 9
Open LV 9
Max PV 16
Cur PV 2
Act PV 2
Max PE per PV 4357
VGDA 4
PE Size (Mbytes) 32
Total PE 8694
Alloc PE 1994
Free PE 6700
Total PVG 0
Total Spare PVs 0
Total Spare PVs in use 0
VG Version 1.0
VG Max Size 2230784m
VG Max Extents 69712
--- Logical volumes ---
LV Name /dev/vg00/lvol1
LV Status available/stale
LV Size (Mbytes) 1824
Current LE 57
Allocated PE 114
Used PV 2
LV Name /dev/vg00/lvol2
LV Status available/syncd
LV Size (Mbytes) 1024
Current LE 32
Allocated PE 64
Used PV 2
LV Name /dev/vg00/lvol3
LV Status available/stale
LV Size (Mbytes) 1024
Current LE 32
Allocated PE 64
Used PV 2
LV Name /dev/vg00/lvol4
LV Status available/stale
LV Size (Mbytes) 32
Current LE 1
Allocated PE 2
Used PV 2
LV Name /dev/vg00/lvol5
LV Status available/stale
LV Size (Mbytes) 5024
Current LE 157
Allocated PE 314
Used PV 2
LV Name /dev/vg00/lvol6
LV Status available/stale
LV Size (Mbytes) 544
Current LE 17
Allocated PE 34
Used PV 2
LV Name /dev/vg00/lvol7
LV Status available/stale
LV Size (Mbytes) 3808
Current LE 119
Allocated PE 238
Used PV 2
LV Name /dev/vg00/lvol8
LV Status available/stale
LV Size (Mbytes) 2624
Current LE 82
Allocated PE 164
Used PV 2
LV Name /dev/vg00/SwapVol2
LV Status available/stale
LV Size (Mbytes) 16000
Current LE 500
Allocated PE 1000
Used PV 2
--- Physical volumes ---
PV Name /dev/disk/disk9_p2
PV Status available
Total PE 4347
Free PE 3350
Autoswitch On
Proactive Polling On
PV Name /dev/disk/disk13_p2
PV Status unavailable
Total PE 4347
Free PE 3350
Autoswitch On
Proactive Polling On
# cat bootconf
l /dev/disk/disk9_p2
l /dev/disk/disk13_p2
# setboot
Primary bootpath : 0/1/1/0.0x1.0x0 (/dev/rdisk/disk9)
HA Alternate bootpath : 0/1/1/1.0x0.0x0 (/dev/rdisk/disk13)
Alternate bootpath : 0/1/2/0 (LAN Interface)
Autoboot is ON (enabled)
Hyperthreading : OFF
: OFF (next boot)
# ioscan –m lun /dev/disk/disk13
Class I Lun H/W Path Driver S/W State H/W Type Health Description
========================================================================
disk 13 64000/0xfa00/0x5 esdisk NO_HW DEVICE disabled HP 146 GST3146855LC
0/1/1/1.0x0.0x0
/dev/disk/disk13 /dev/disk/disk13_p2 /dev/rdisk/disk13 /dev/rdisk/disk13_p2
/dev/disk/disk13_p1 /dev/disk/disk13_p3 /dev/rdisk/disk13_p1 /dev/rdisk/disk13_p3
Then from the below i was able to identify it physicaly
# dd if=/dev/dsk/c3t0d0 of=/dev/null bs=1024
/dev/dsk/c3t0d0: No such device or address
dd: cannot open /dev/dsk/c3t0d0
# dd if=/dev/dsk/c2t1d0 of=/dev/null bs=1024
2339888+0 records in
2339888+0 records outAny help will be great, Thank you. Last edited by Scott; 05-23-2012 at 04:39 AM.. Reason: Code tags, please... |
| Sponsored Links | ||
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | |
More UNIX and Linux Forum Topics You Might Find Helpful
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Remove faulty disk LV from VG | Shirishlnx | HP-UX | 5 | 04-24-2012 10:27 PM |
| Remove Faulty disk from HP-UX LVM VG | Shirishlnx | HP-UX | 9 | 04-13-2012 10:05 AM |
| Help with faulty Disk on Sun OS | phanidhar6039 | Solaris | 3 | 03-30-2012 03:12 PM |
| Removing Faulty Disk SSA | vuppala360 | AIX | 2 | 09-08-2008 11:59 AM |
| Disk Replacement SVM | Actuator | Solaris | 4 | 05-21-2008 01:14 AM |
|
|