vPar Hardware Paths


 
Thread Tools Search this Thread
Operating Systems HP-UX vPar Hardware Paths
# 1  
Old 09-02-2009
vPar Hardware Paths

I wonder if anyone could assist with this.

We have taken over administration of an rp8440 that has been split into 2 nPars and has 4vPars per nPar.

I have to add a network card into one of the vPars that was missed at the time the vPar was created. That bit i have no problem with.

The issue i have is that i do not know which of the available resources relates to this i/o slot, so i wonder if anyone could give me any ideas on how to find this out. I am sure there must be a way of working it out, but i cannot figure it out.

I know the card is in chassis 0, slot 1

Available resources from vparstatus -A command

[Available I/O devices (path)]: 0.0.1
0.0.2
0.0.8
0.0.10
0.8.1
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. HP-UX

How to shutdown a vpar from another vpar?

Hi, How can I shutdown a vpar from another vpar ? Please provide the command. Thanks. (0 Replies)
Discussion started by: snchaudhari2
0 Replies

2. HP-UX

VPAR Resource Capacity Limit

Hello Guys Could you please let me know the command to find the resource (vCPU & Memory) capacity limit for the VPAR's (HPUX 11.23) on integrity Virtual host servers running HPUX 11.31 OS. For eg. I want to know what is the max vCPU and memory that I can assign to one VPAR. The Base Virtual... (0 Replies)
Discussion started by: prvnrk
0 Replies

3. HP-UX

VPar hardware migration - ERRATA document

Hi guys, I'm moving some vPars from BL860c I2 and BL870c I2 using the DRD clone and relocation. In some case, as instance to upgrade to BL870c I2, the ERRATA document reports some additional driver to be added to the image made by the DRD and then recompile the kernel before the move to the... (0 Replies)
Discussion started by: cecco16
0 Replies

4. Programming

Can't find paths.h

I wasn't sure which forum to post this in. I am trying to compile logsurfer. After I run configure and the make, I get a complaint that paths.h is not found. I see three places where there is a paths.h: /usr/include/pgsql/server/optimizer/paths.h... (3 Replies)
Discussion started by: brownwrap
3 Replies

5. Solaris

Hardware faulty, but which hardware?

Hi folk, I have this hardware faunty message, but dont know which hardware is this ? can you guide me ? --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY ---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies

6. HP-UX

vPar Boot Error

Hi All, Please help me out in below issue in creating vPar. We have one nPar in which we have to create 2 vPars, out of which first vPar is already created and it is running well which have local disk as a boot device.Now we have to create 2nd vPar which need to use SAN disk for booting.... (3 Replies)
Discussion started by: laxmikant
3 Replies

7. HP-UX

vpar ignite

Hi Can I use a vpar as an ignite server? (1 Reply)
Discussion started by: mahlathini
1 Replies

8. UNIX for Advanced & Expert Users

Spoofing paths.

There is a program that I am trying to run on a shell account. It depends on another program, which I have also copied to the shell account. Both are in my home directory, yet the first program has a different path hardcoded into it, which I cannot use because of permissions problems. How can I... (3 Replies)
Discussion started by: fahadsadah
3 Replies

9. UNIX for Dummies Questions & Answers

create paths

Hello! If I have file like that: AAA ->bbb ->ccc ->ddd ->eee how to create full paths like: AAA->bbb AAA->ccc->ddd AAA->ccc->eee ? (I'm sorry for mistakes - english is not my native language) :) (4 Replies)
Discussion started by: alias47
4 Replies

10. UNIX for Dummies Questions & Answers

paths

Hi there! People, i'm a new unix user, and i'm having some problems... I'm updating some scripts (korn shell) in different servers. I use telnet to access these servers and emacs to write the scripts. One of them is an HP, and there´s no problem. But the other one is an AIX, and when i call... (1 Reply)
Discussion started by: caiohn
1 Replies
Login or Register to Ask a Question
vparenv(1M)															       vparenv(1M)

NAME
vparenv - display or set the environment for the next boot SYNOPSIS
mode] memtype:size] DESCRIPTION
The command displays or sets appropriate firmware variables on Itanium-based platforms. The variables manage the partition boot mode ( or CLM granularity and ILM granularity. By default, the command displays the current settings of the partition boot mode and memory granular- ities. The command also displays the maximum possible ILM granules for the system and the maximum possible CLM granules per cell. Note: This information is displayed by the command only if the system has been switched to vPars mode atleast once after a system reset. Users should consider these maximums when specifying either granularity. Care should be taken to choose granule sizes which do not result in the total number of granules exceeding the permissible limits for that system. In certain scenarios, the command may not be able to validate if the chosen memory granularities are appropriate for the system. The com- mand will display a warning message. In such cases, the user should validate the granularities against the total memory on the system and the supported number of memory granules on the system. Please refer to manpage for more details. Note: This command does not modify the ILM/CLM granule values in the vPars database file. It only modifies the appropriate EFI variables. This command is not supported on PA-RISC platforms. Options and Arguments recognizes the following command line options and arguments: Specifies the mode for the next system boot. The valid values for mode are case-insensitive If mode is specified as then after the next reboot, the system will be in the vPars mode. If mode is specified as then after the next reboot, the system will be in the nPars mode. Note: The mode setting does not take effect until the next system (hard partition) reboot. Specifies the desired granularity of Cell Local Memory (CLM) or InterLeaved Memory (ILM) to be set in the appropriate EFI variable. memtype specifies the type of memory. The valid values are case insensitive and size specifies the desired granularity in megabytes. Note: The granule settings do not take effect until the next system (hard partition) reboot. WARNINGS
The EFI granule settings must be the same as those in the vPar database loaded into the monitor. If one or both settings do not match, the monitor will not allow any vPar to boot. Refer to the vparcreate(1M) manpage. To correct this, you must either change the EFI variables using this command or change the granularity values in the database file by recreating the database using EXAMPLES
Set the boot mode to Set the CLM granularity to 128 MB. Set the ILM granularity to 128 MB and CLM granularity to 128 MB. SECURITY RESTRICTIONS
This command is restricted to processes owned by superuser. When virtual partition flexible administrative capability is enabled, the boot environment firmware variables can only be set from within a Designated-Admin vPar. RETURN VALUE
The command exits with one of the following values: Successful completion. An error condition occurred. AUTHOR
was developed by the Hewlett-Packard Company. SEE ALSO
vparadmin(1M), vparboot(1M), vparconfig(1M), vparcreate(1M), vpardump(1M), vparefiutil(1M), vparextract(1M), vparmodify(1M), vparreloc(1M), vparremove(1M), vparreset(1M), vparstatus(1M), vparutil(1M), vparresources(5), vpartition(5), vpmon(5). Itanium(R)-based Systems Only vparenv(1M)