StorageTek 2540 battery failed

 
Thread Tools Search this Thread
Special Forums Hardware StorageTek 2540 battery failed
# 1  
Old 10-19-2011
Error StorageTek 2540 battery failed

Hi all,

My Sun StorageTek 2540 have redundant batteries, but a battery was failed.

Code:
# /opt/SUNWstkcam/bin/sscs list -d MyStorage1 fru
Name                       FRU         Alarm    State               Status Revision    Unique Id
-------------------------- ----------- -------- ------------------- ------ ----------- ----------------------------
Tray.85.Battery.A          Battery     -        Enabled             OK     N/A         SY81500764SA
Tray.85.Battery.B          Battery     Critical Enabled but Offline Error  N/A         SY81500830SA

After the battery failure, the server read/write performance was down (I assume)!

I read some doc from internet and I found a reason to performance down when storage array battery failed. A guy tell me you should change "Write Cache without Batteries" option to ENABLE on the storage volume using SSCS CLI utility.

Command is below:
/opt/SUNWstkcam/bin/sscs modify -a MyStorage -p disk_pool -b enable

I afraid that lost any data on the storage box after execute above command.

Please tell me what happening when I execute " /opt/SUNWstkcam/bin/sscs modify -a MyStorage -p disk_pool -b enable" command on the storage box?

BR,
Buyantugs

Last edited by DukeNuke2; 10-19-2011 at 07:51 AM..
# 2  
Old 10-19-2011
in case of a power outage you will lose any data in cache which isn't (yet) written to disks... a new battery would be the safer way!
# 3  
Old 10-19-2011
Hi DukeNuke2

I understand the batter replace is safer way but performance lost is more important for me.
if no power outage during new battery order completion period, I should change above option on disk cache? Am i right?
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. Solaris

Server M4000 server lost connectivity to storagetek 2540

Hi Guys, I have situation here ... server M4000 server lost connectivity to storagetek 2540 , storagetek 2540 unable to be ping.From DAS URL the storage is undetected. Any idea why this is happening. Please share. Thank you. Raj (1 Reply)
Discussion started by: muralirajah
1 Replies

2. Solaris

StorageTek 2540 SAN array

Bought a Sun StorageTek 2540 SAN array a few years ago from a company that was going out of business. When we first set it up, we were able to get all the software (Common Array Manager) and firmware directly from Sun. We just upgraded the drives, but the array is too large for the firmware. Now... (6 Replies)
Discussion started by: edison303
6 Replies

3. Hardware

Storagetek 2540

Hi Guys and Gals, Wionder if you could help me, got a problem with a controller on a storagetek 2540, dead when fully powered up but if you reboot, it is ok for a couple of seconds (and you can ping it). Then once the array is fully up, it goes faulty and is un-pingable. Had anyone... (4 Replies)
Discussion started by: callmebob
4 Replies

4. Solaris

SUN 6540 Array with failed controller battery

Can someone point me to a procedure detailing the replacement of a failed battery in a SUN 6540 controller. Or describe the procedure. Thanks (1 Reply)
Discussion started by: USFE
1 Replies

5. Hardware

Storagetek 2540

Hello all ! I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server. I... (2 Replies)
Discussion started by: acorradi
2 Replies

6. Solaris

Storagetek 2540

Hi peeps, Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables. Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies

7. Solaris

Sun StorageTek 2540 - shutdown matrix

Hi, I have a simple question on how to correctly disable the matrix? Looking for the Common Array Manager and I do not see this option... Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies

8. Filesystems, Disks and Memory

Configure large volume on Sun StorageTek 2540 array

Hi, We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies

9. Solaris

One StorageTek 6140 vs Two (2) 2540 's?

We're moving our production 3510FC to development, so we need to replace the production 3510FC. The 6140 is nice, but pricey. Here's the question: Would two 2540's (RAID 10) be 'faster' than one 3510? (RAID 10) and faster than one 6140 (RAID 10)? One StoregeTek 6140 (16x72GB 15k rpm fc-al... (12 Replies)
Discussion started by: buddhavelvet
12 Replies

10. Solaris

Sun Sparc T2000 + StorageTek 2540 - Help, I'm lost

I have a Sun Sparc T2000 (Solaris 10 05-08) and have installed a PCI-X 4GB Single Port HBA card in it. I have one StorageTek 2540 array that I would like to connect to the T2000. For the moment it would be a single path connection, but I've ordered a 2nd HBA, so eventually it would be... (4 Replies)
Discussion started by: soliberus
4 Replies
Login or Register to Ask a Question