Fan Tray for Sunfire T2000

Recently the rear fan assembly of one of our T2000 servers went faulty. I could replace it immediately with the one from a currently powered off standby machine. But now this one has to be replaced.

So I got a quote from our supplier who charges EUR 776 for a new spare part or EUR 405 (all excluding VAT) for a refurbished one, which seems a bit extreme for a piece of metal and a fan.

Does anyone know a cheaper source for this part (refurbished would be OK) in Europe? The Sun Part # is 541-0645.

Thanks!
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. Hardware

How to remove fan from cpu fan chassis?

hi all, kindly help in this matter. Can i check anyone has any experience in removing the CPU fan from its chassis? my fan is spoilt and i wish to replace with other type. See picture below.. http://zone11.codemicroinc.netdna-cdn.com/large_1054367.jpg ---------- Post updated at 05:15 PM... (6 Replies)
Discussion started by: lchunleo
6 Replies

2. Solaris

SunFire T2000 ipmievd error

I'm running Solaris 10 (09/10) on Sun Fire T2000. This error message is logged repeatedly in /var/adm/messages: May 22 10:40:33 EBDW01 last message repeated 25 times May 22 10:40:36 EBDW01 ipmievd: Reading sensors... May 22 10:40:40 EBDW01 ipmievd: Error obtaining SDR info: Unknown... (4 Replies)
Discussion started by: Sun Fire
4 Replies

3. Linux

Required Icon Tray in Linux

Hello I am using linux machine. I need Icon tray in this. "Icon Tray" contains all the icons which we open in the workspace. As such, these icons appear at the bottom (similar to windows i.e.when we open internetexplorer, Word, XLs, these icons appear in the bottom) I have to open so many... (3 Replies)
Discussion started by: nehashine
3 Replies

4. Solaris

Memory problems on a -sunfire T2000

I work with a network management tool, which, for various reasons, is installed on a solaris server.This is a Sunfire T2000 server with 16 CPUs and 8GB of RAM. I have installed a Solaris 10 ZFS and 8GB swap. From the beginning I had problems with memory occupation that it rises progressively to 95%... (4 Replies)
Discussion started by: drusa79
4 Replies

5. Solaris

d240 media tray is automatically restarting on sunfire 6800

d240 media tray(domain C) is which is connected to SUNFIRE 6800 (DOMAIN C),automatically restarting.remaining domains A and B are working fine..why i dont know..with out human intervention this domain is restarting automatically for 3 to 4 days in a day..plz solve this problem.why like this going... (4 Replies)
Discussion started by: tv.praveenkumar
4 Replies

6. AIX

chvirprt and tray 1

Hi, I'm not able to print on tray 1. I checked the configuration and I get these 3 options: $lsvirprt -q print1 -d hp@xprint -a _O Name Description Value _O Type of INPUT PAPER HANDLING (backward 1 ... (0 Replies)
Discussion started by: imad77
0 Replies

7. AIX

AIX Laserjet 4+ specify tray to print to

Is it possible to specify the tray you would like to print to in AIX? We are using the laserjet 4+ driver. Thanks in advance (0 Replies)
Discussion started by: zuessh
0 Replies

8. UNIX for Advanced & Expert Users

tray selection

Hello All, Could anyone help me how to selecting the trays in unix . Thanks, Amit kul (3 Replies)
Discussion started by: amit kul
3 Replies

9. UNIX for Advanced & Expert Users

tray selection using lp command

I have a HP laserjet 9000 printer on a Sun Solaris server. I try to print using lp command to different trays. But it gives an error. The command that i used is lp -dprinter_queue -otray2 file_name (1 Reply)
Discussion started by: avinashrm
1 Replies
Login or Register to Ask a Question
DBCOOL(4)						   BSD Kernel Interfaces Manual 						 DBCOOL(4)

NAME
dbcool, adm1027, adm1030, adm1031, adt7463, adt7466, adt7467, adt7468, adt7473, adt7475, adt7476, adt7490, emc6d103s -- dbCool(tm) family of environmental monitors and fan controllers SYNOPSIS
dbcool* at ki2c? dbcool* at iic? addr 0x2e DESCRIPTION
The dbcool driver provides support for the Analog Devices dbCool and the SMSC EMC6D103S environmental monitor chips to be used with the envsys(4) API. These chips support up to fifteen sensors. Not all of the following sensors are supported on all chips. Sensor Units Typical Use l_temp uK local chip temperature r1_temp uK CPU temperature r2_temp uK GPU temperature Vccp uV DC CPU Vcore Vcc uV DC Chip's supply voltage 2.5V uV DC 2.5V supply 5V uV DC 5V supply 12V uV DC 12V supply Vtt uV DC PECI ref. voltage (2.25V ref, ADT7490 only) Imon uV DC Current monitor (2.25V ref, ADT7490 only) AIN1 uV DC Analog In (2.25V ref, ADT7466 only) AIN2 uV DC Analog In (2.25V ref, ADT7466 only) fan1 RPM Chassis Fan fan2 RPM Chassis Fan fan3 RPM Chassis Fan fan4 RPM Chassis Fan VID (none) CPU VID code (selected chips only) Each temperature and voltage sensor has programmable hardware high- and low-limits; fan sensors have only a low-limit. These limits can be set using the envstat(8) utility. Due to hardware limitations, the minimum permissible value for the fan speed low-limits is 83 RPM. Temperature sensors also have Tmin, Trange, Thyst, and Ttherm sysctl(8) variables; these values are used by the fan speed controllers. Their values are in units of degC, since this is the unit which is programmed into the device registers. All members of the dbCool family support Pulse-Width Modulated (PWM) fan speed control based on temperature thresholds - the fan will spin up when its associated thermal sensor(s) exceeds its configured Tmin value. The fan will go faster as the temperature rises, and will slow down as the temperature falls. If the temperature exceeds the sensor's Ttherm value, the THERM signal will be asserted, and if enabled the fan will run at full speed. The fan will be turned off when the sensor(s) that triggered it reports a temperature which is at least Thyst degrees below its Tmin threshold. Each fan controller is programmable using the following sysctl(8) variables. hw.dbcool0.fan_ctl_0.behavior hw.dbcool0.fan_ctl_0.min_duty hw.dbcool0.fan_ctl_0.max_duty hw.dbcool0.fan_ctl_0.cur_duty The behavior variable controls the selection of temperature sensors associated with the fan controller. When the associated temperature sen- sor reaches its Tmin value, the fan controller starts the fan at its minimum duty cycle; when the associated temperature sensor reaches its Ttherm value and asserts the THERM signal (or if an external THERM signal is asserted), the fan controller sets the fan speed to a 100% duty cycle. Between these two settings, each temperature sensor is used to calculate a duty cycle linearly based on the slope defined by the tem- perature sensor's range variable. When the associated temperature falls at least Thyst degress below its Tmin value, the fan controller will turn off the fan. (On the ADM1030, the value for Thyst is fixed at 5 degC.) Valid values for the behavior variable are: local (not available on ADM1030) remote1 remote2 (not available on ADM1030) local+remote2 (not available on ADM1030) all-temps full-speed (not available on ADM1030) manual disabled When the behavior variable is set to ``manual'', the cur-duty variable becomes user-writable and can be set to any value between 0 and 100 inclusive to control the fan's duty cycle manually. In all other behavior modes, the cur-duty variable is read-only and updates are ignored. The min-duty and max-duty variables define the range over which the fan controller will manage the fan's duty cycle. On the ADM1030, these values are not separately controllable. The max-duty is fixed at 100%, and the cur-duty variable is used to specify the minimum duty cycle when the fan controller is running in automatic mode. Note that the duty-cycle value does not directly correspond to the fan's speed. That is, a 33% duty cycle does not mean that the fan runs at 33% of its maximum speed; in actuality, a 33% duty cycle drives the fan at a speed close to 50% of its maximum. Fan speed correlates approx- imately to the square root of the duty cycle. EXAMPLES
The envstat(8) utility can be used to determine the sensors supported: Current CritMax WarnMax WarnMin CritMin Unit l_temp: 44.250 degC r1_temp: 41.250 degC r2_temp: N/A Vccp: 0.002 V Vcc: 3.351 V fan1: N/A fan2: N/A fan3: N/A fan4: N/A Using this information, the following commands in /etc/envsys.conf will set appropriate limits for CPU temperature and chip supply voltage, and powerd will be notified if the limits are exceeded: dbcool0 { sensor1 { warning-max = 60C; critical-max = 65C; } sensor4 { critical-min = 3.1; warning-min = 3.2; critical-max = 3.5; } } SEE ALSO
envsys(4), iic(4), envstat(8), powerd(8), sysctl(8) HISTORY
The dbcool device appeared in NetBSD 5.0. BUGS
Although the sensor limit registers can be programmed, there is currently no use of the dbCool chips' ability to generate an SMBus interrupt when the limits are exceeded. Limit checking and event generation are done in software, and are performed only when the sensor values are polled and refreshed. The ADT7466 chip, although officially a member of the dbCool family, is programmed quite differently. The fan controllers on this chip are not currently implemented. The PECI (Processor Environment Control Interface) temperature sensors and the associated PWM behavior modes on the ADT7490 are not currently supported. BSD
March 12, 2011 BSD