Hej og Velkommen fra USA til UNIX og Linux Forums! Tak for dit besøg og deltager i vores globale samfund.
|
|
google unix.com
|
|||||||
| Forums | Registrer | Forum Regler | Links | Albums | FAQ | Members List | Kalender | Søgning | Dagens Stillinger | Mark Forums Read |
| Sun Solaris Solaris-operativsystemet, normalt kendt som Solaris, er en fri Unix-baserede styresystem introduceret af Sun Microsystems. |
Mere UNIX og Linux Forum Emner du måske kan finde Helpful
|
||||
| Tråd | Thread Starter | Forum | Svar | Last Post |
| Problemer med awk | RichieFondel | Shell Programmering og Scripting | 1 | 01-17-2008 07:30 AM |
| X problemer | izua | UNIX for dummyer Spørgsmål & svar | 0 | 01-03-2007 06:19 PM |
| Problemer med tr | Mike @ Work | Sun Solaris | 8 | 08-10-2006 03:04 PM |
| Problemet omkring SU ... | nulnul7 | UNIX for dummyer Spørgsmål & svar | 4 | 10-05-2005 11:39 AM |
| Problemet med ... | zazzybob | Hvad tænker du på? | 6 | 01-18-2005 06:01 AM |
![]() |
|
|
LinkBack | Thread Tools | Søg denne tråd | Rate Thread | Display Modes |
|
|
|
||||
|
Enterprise3500 problemer
Hej,
Min magt for at SCSI-side, og fcal intern disk-stik er gone.When jeg tænder på tasten, fans under mit diske bare spin i 2 sekunder for derefter dø. Om bord 1 alle tre lysdioder er på, om powersupplyboard (med 1 / 0 Swith og powercable) det gule lys er tændt. Jeg prøvede en masse i OBP, men det hele slutter med "login-all? Mislykkedes" Det plejer starte op fra de diske, men den anerkender dem imidlertid, og det plejer starte op fra cd-rom'en drive.I har prøvet at fjerne et bord efter en anden til foind en defekt en, men ikke til noget resultat andet end beskrevet: "login-all? mislykkedes. jeg gjorde" reset-all "mellem hver" sonde-SCSI-all "og" sonde-fcal-all " probe-scsi-alle giver: / pci @ 13,4000 / SUNW, isptwo @ 3 / SBUS @ 2,0 / SUNW, fas @ 2,8800000 / SBUS @ 3,0 / SUNW, fas @ 3,8800000. probe-fcal-alle giver: / SBUS @ 2,0 / SUNW, SoCaL @ d, 10000/sf @ 1,0 login-all? mislykkedes login-all? mislykkedes / SBUS @ 2,0 / SUNW, SoCaL @ d, 10000/sf @ 0,0 login-all? mislykkedes login-all? mislykkedes (6) ok Ideer? ![]() |
|
||||
|
Jeg kan ikke boot fra cdrom, hele scsi side af maskinen er ikke-funktionel. Den cdrom wonteven åbne, og den disk (e) dont spin, neitherthe fans nedenunder. De tænder for nogle gange 3 sekunder, nogle gange 3 minutter. Skal være den strømforsyning, men jeg har aldrig hørt om en der blev dårlig, så jeg tænkte jeg kan ved et uheld har slået sig ned af med nogle underlige fejlstavede comando.
Her er det serialoutput: Hardware Power ON 3,0> ERROR: test \u003d Environmental Probe, Deltestniveau \u003d Environmental Probe ID \u003d 1f.1 3,0> Component under test: Board 3 System Interrupt 3,0> Peripherial Power Supply PPSS_0 Failed 3,0> ERROR: test \u003d Environmental Probe, Deltestniveau \u003d Environmental Probe ID \u003d 1f.1 3,0> Component under test: Board 3 System Interrupt 3,0> Peripherial Power Supply PPSS_0 Failed 3,0> ERROR: TEST \u003d System Interrupts, Deltestniveau \u003d System Interrupts ID \u003d 1f.1 3,0> Component under test: Board 3 System Interrupt 3,0> Peripherial Power Supply PPSS_0 Failed 3,0> ERROR: TEST \u003d System Interrupts, Deltestniveau \u003d System Interrupts ID \u003d 1f.1 3,0> Component under test: Board 3 System Interrupt 3,0> Peripherial Power Supply PPSS_0 Failed 5-slot Sun Enterprise E3500, No Keyboard OpenBoot 3.2.30, 8192 MB installeret hukommelse, Serial # 10.563.790. Copyright 2002 Sun Microsystems, Inc. Alle rettigheder forbeholdt Ethernet-adressen 8:0:20: A1: 30: CE, Host ID: 80a130ce. (6) ok |
|
||||
|
(6) ok show-post-resultater
Slot 1 - Status \u003d Okay, Type: I / O-Type 4 Sysio0 \u003d P Sysio1 \u003d P FEPS \u003d P FEPSFC \u003d 0 SOC \u003d P Sbus0 \u003d P Sbus1 \u003d P Sbus2 \u003d P AC \u003d P FHC \u003d P SRAM \u003d P FPROM \u003d P LabCon \u003d Ikke Ovtemp \u003d Ikke TODC \u003d P JTAG \u003d P CntrPl \u003d P DC \u003d ff Slot 3 - Status \u003d Okay, Type: CPU / Memory CPU0 \u003d P CPU0-OK \u003d P FailCode \u003d 0 Cpu1 \u003d P Cpu1-OK \u003d P FailCode \u003d 0 AC \u003d P FHC \u003d P SRAM \u003d P FPROM \u003d P LabCon \u003d Ikke Ovtemp \u003d Ikke Bank0 \u003d 0 Bank1 \u003d 0 DTag0 \u003d P DTag1 \u003d P JTAG \u003d P CntrPl \u003d P Bank0 \u003d P Bank1 \u003d P DC \u003d ff Slot 5 - Status \u003d Okay, Type: I / O-Type 3 Sysio0 \u003d P Sysio1 \u003d P FEPS \u003d*** FEPSFC \u003d 0 SOC \u003d*** Sbus0 \u003d*** Sbus2 \u003d*** AC \u003d P FHC \u003d P SRAM \u003d P FPROM \u003d P LabCon \u003d Ikke Ovtemp \u003d Ikke TODC \u003d P JTAG \u003d P CntrPl \u003d P DC \u003d ff Slot 7 - Status \u003d Okay, Type: CPU / Memory CPU0 \u003d P CPU0-OK \u003d P FailCode \u003d 0 Cpu1 \u003d P Cpu1-OK \u003d P FailCode \u003d 0 AC \u003d P FHC \u003d P SRAM \u003d P FPROM \u003d P LabCon \u003d Ikke Ovtemp \u003d Ikke Bank0 \u003d 0 Bank1 \u003d 0 DTag0 \u003d P DTag1 \u003d P JTAG \u003d P CntrPl \u003d P Bank0 \u003d P Bank1 \u003d P DC \u003d ff Slot 9 - Status \u003d Okay, Type: I / O-Type 3 Sysio0 \u003d P Sysio1 \u003d P FEPS \u003d*** FEPSFC \u003d 0 SOC \u003d*** Sbus0 \u003d*** Sbus2 \u003d*** AC \u003d P FHC \u003d P SRAM \u003d P FPROM \u003d P LabCon \u003d Ikke Ovtemp \u003d Ikke TODC \u003d P JTAG \u003d P CntrPl \u003d P DC \u003d ff Slot 16 - Status \u003d Fail, Type: Clock Ur \u003d P Serial \u003d P KbdMse \u003d P PPS-DC \u003d*** DCReg0 \u003d P DCReg1 \u003d P AC \u003d P ACFan \u003d P KeyFan \u003d P PSFail \u003d 0 Ovtemp \u003d Ikke TODC \u003d P V5-P \u003d P V12-P \u003d P V5-Aux \u003d P V5P-PC \u003d P V12-PC \u003d P V3-PC \u003d P V5-PC \u003d P RckFan \u003d*** 3.3V \u003d P 5.0V \u003d P triger \u003d P Coolng \u003d P AC-REV \u003d P P \u003d Nuværende eller Bestået *** \u003d Failed Komponent Ikke \u003d Ikke til stede (6) ok Kan du fortælle mig whatis brudt, fra readingthis? M |
|
||||
|
Udskift din strømforsyningen.
Der er formentlig ikke strøm nok på vej gennem strømfordelingen bord til MB og dets komponenter, hvilket medfører, blæsere at køre med lav hastighed eller endog at dø, som igen vil medføre CPU'en til at varme op og temp-sensorer registrerer det og kræfter til at slukke systemet .. ![]() |
|
||||
|
Ja, der er blevet indgåelse af mange mennesker så langt, men da jeg bor i Sverige, jeg har ikke været i stand til at komme på tværs af en billig endnu, vil det koste mig 400 dollars for at få en fra staterne. The Sun nummer er 300-1400-01 og hvis nogen `s fik sig om rundt, og kan give mig et bedre tilbud, ville jeg glade for det.
Magnus vatch23@riseup.net ![]() |
![]() |