Sponsored Content
Full Discussion: how many disks do I have?
Top Forums UNIX for Dummies Questions & Answers how many disks do I have? Post 9663 by Neo on Wednesday 31st of October 2001 07:18:28 PM
Old 10-31-2001
Note to pmetal

HTML is allowed in posts, so if you want to make a diagram, just create a little graphic (jpg, gif) and add the link using standard HTML IMG tags. Notice that there is an IMG tag when you post to make it a tiny-bit less typing.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Disks on AIX

Hello I've been working on AIX 5.3 ML3 on IBM pSeries520. That server has 6 HDD drives in 3 volume groups (1+mirror in each group). I must check which phisical disk is which disk in the system. For ex. I want to know that disk in 4th slot in the machine is marked as hdisk5 on AIX. Does anybody... (2 Replies)
Discussion started by: piooooter
2 Replies

2. AIX

SCSI Disks

Hi Is it possible to install in p5 and pSeries SCSI Disks from SUN on DELL? Will they work? Regards, Pit (0 Replies)
Discussion started by: piooooter
0 Replies

3. Solaris

New Array of disks

I was just curious if anyone has a good tutorial or some info about how I can create and add an array of disks to solaris 8 (11 Replies)
Discussion started by: BRaider
11 Replies

4. Solaris

What do you use to wipe your disks?

What are y'all using to wipe your solaris disks? I am being question by IT Security, what I am using to wipe disk. Is anyone using a 3rd party utility? I have used the format utility in solaris previously. But they are looking for something commercial that I can use. Anyone have... (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies

5. AIX

disks broke?

hay I'm new in the AIX-environment. Right now i'm testing some stuff out. But i can't test the LVM-part which is (to me) very important. I have 2 disks in my testmachine but it seems only 1 is working wel. I'll show you the output below of the disks... hdisk0 = in good condition hdisk2 =... (8 Replies)
Discussion started by: kvanelshocht
8 Replies

6. Solaris

disks in solaris

whats the command to find name of all disks. Is it iostat -En ? (1 Reply)
Discussion started by: vikashtulsiyan
1 Replies

7. Solaris

Re-using disks

I would like to know if I can move the disks from a V240 chassis into a V440 chassis to use the increased resources (CPU & Memory) to boost performance. I know you can move disks between V210/240 chassis's, but I'm not sure if this would work between 240s & 440s. Any help would be much appreciated. (4 Replies)
Discussion started by: Chains
4 Replies

8. Solaris

host cannot see FC disks

Have a V440 server which we need to connect up to a SE6140. Did the zoning on the 3900 brocade silkworm and did mapping from the array to the host manually host initiator did not autodetect the wwn and had to key in manually. probe-scsi-all cannot show the fc disks. What is the problem here? (7 Replies)
Discussion started by: incredible
7 Replies

9. Filesystems, Disks and Memory

FC related disks

Dear Friends, I would like know what are FC related disks and how it will be viewed by generic OSes (Unix, Unix like, Windows & etc.) AFAIK it is viewed by generic OS as SCSI. Can we have FC related disks as internal storage(physically) of general purpose machine (Server / PC /... (1 Reply)
Discussion started by: Tlogine
1 Replies

10. Solaris

How to tell what disks are used for a zpool?

Hello, Does anyone know how I can tell what disk are being not being used by a zpool? For example in Veritas Volume manager, I can run a "vxdisk list" and disks that are marked as "online invalid" are disk that are not used. I'm looking for a similar command in ZFS which will easily show... (5 Replies)
Discussion started by: robertinoau
5 Replies
scdpm(1M)						  System Administration Commands						 scdpm(1M)

NAME
scdpm - manage disk path monitoring daemon SYNOPSIS
scdpm [-a] {node | all} scdpm -f filename scdpm -m {[node | all][:/dev/did/rdsk/]dN | [:/dev/rdsk/]cNtXdY | all} scdpm -n {node | all} scdpm -p [-F] {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} scdpm -u {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scdpm command manages the disk path monitoring daemon in a cluster. You use this command to monitor and unmonitor disk paths. You can also use this command to display the status of disk paths or nodes. All of the accessible disk paths in the cluster or on a specific node are printed on the standard output. You must run this command on a cluster node that is online and in cluster mode. You can specify either a global disk name or a UNIX path name when you monitor a new disk path. Additionally, you can force the daemon to reread the entire disk configuration. You can use this command only in the global zone. OPTIONS
The following options are supported: -a Enables the automatic rebooting of a node when all monitored disk paths fail, provided that the following conditions are met: o All monitored disk paths on the node fail. o At least one of the disks is accessible from a different node in the cluster. You can use this option only in the global zone. Rebooting the node restarts all resource and device groups that are mastered on that node on another node. If all monitored disk paths on a node remain inaccessible after the node automatically reboots, the node does not automatically reboot again. However, if any monitored disk paths become available after the node reboots but then all monitored disk paths again fail, the node automatically reboots again. You need solaris.cluster.device.admin role-based access control (RBAC) authorization to use this option. See rbac(5). -F If you specify the -F option with the -p option, scdpm also prints the faulty disk paths in the cluster. The -p option prints the cur- rent status of a node or a specified disk path from all the nodes that are attached to the storage. -f filename Reads a list of disk paths to monitor or unmonitor in filename. You can use this option only in the global zone. The following example shows the contents of filename. u schost-1:/dev/did/rdsk/d5 m schost-2:all Each line in the file must specify whether to monitor or unmonitor the disk path, the node name, and the disk path name. You specify the m option for monitor and the u option for unmonitor. You must insert a space between the command and the node name. You must also insert a colon (:) between the node name and the disk path name. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -m Monitors the new disk path that is specified by node:diskpath. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -n Disables the automatic rebooting of a node when all monitored disk paths fail. You can use this option only in the global zone. If all monitored disk paths on the node fail, the node is not rebooted. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -p Prints the current status of a node or a specified disk path from all the nodes that are attached to the storage. You can use this option only in the global zone. If you also specify the -F option, scdpm prints the faulty disk paths in the cluster. Valid status values for a disk path are Ok, Fail, Unmonitored, or Unknown. The valid status value for a node is Reboot_on_disk_failure. See the description of the -a and the -n options for more information about the Reboot_on_disk_failure status. You need solaris.cluster.device.read RBAC authorization to use this option. See rbac(5). -u Unmonitors a disk path. The daemon on each node stops monitoring the specified path. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). EXAMPLES
Example 1 Monitoring All Disk Paths in the Cluster Infrastructure The following command forces the daemon to monitor all disk paths in the cluster infrastructure. # scdpm -m all Example 2 Monitoring a New Disk Path The following command monitors a new disk path.All nodes monitor /dev/did/dsk/d3 where this path is valid. # scdpm -m /dev/did/dsk/d3 Example 3 Monitoring New Disk Paths on a Single Node The following command monitors new paths on a single node. The daemon on the schost-2 node monitors paths to the /dev/did/dsk/d4 and /dev/did/dsk/d5 disks. # scdpm -m schost-2:d4 -m schost-2:d5 Example 4 Printing All Disk Paths and Their Status The following command prints all disk paths in the cluster and their status. # scdpm -p schost-1:reboot_on_disk_failure enabled schost-2:reboot_on_disk_failure disabled schost-1:/dev/did/dsk/d4 Ok schost-1:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d5 Unmonitored schost-2:/dev/did/dsk/d6 Ok Example 5 Printing All Failed Disk Paths The following command prints all of the failed disk paths on the schost-2 node. # scdpm -p -F all schost-2:/dev/did/dsk/d4 Fail Example 6 Printing the Status of All Disk Paths From a Single Node The following command prints the disk path and the status of all disks that are monitored on the schost-2 node. # scdpm -p schost-2:all schost-2:reboot_on_disk_failure disabled schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok EXIT STATUS
The following exit values are returned: 0 The command completed successfully. 1 The command failed completely. 2 The command failed partially. Note - The disk path is represented by a node name and a disk name. The node name must be the host name or all. The disk name must be the global disk name, a UNIX path name, or all. The disk name can be either the full global path name or the disk name: /dev/did/dsk/d3 or d3. The disk name can also be the full UNIX path name: /dev/rdsk/c0t0d0s0. Disk path status changes are logged with the syslogd LOG_INFO facility level. All failures are logged with the LOG_ERR facility level. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cldevice(1CL), clnode(1CL), attributes(5) Sun Cluster System Administration Guide for Solaris OS Sun Cluster 3.2 22 Jun 2006 scdpm(1M)
All times are GMT -4. The time now is 07:55 AM.