10-15-2014
I will gather the details and get back to you.
Best regards,
Vishal
---------- Post updated at 07:34 AM ---------- Previous update was at 07:03 AM ----------
Thanks!
This is the model no.
HK192604373
Best regards,
Vishal
10 More Discussions You Might Find Interesting
1. Solaris
Hello
We have a power supply in an x4100 (x86) and it seems to be faulty but it is still working!?! (this box only has one PSU). We are getting Orange flashing warning light on the front of the box and the LED labelled “rear PSu” is solid orange ...We don't seem to have had any syslog error... (8 Replies)
Discussion started by: hcclnoodles
8 Replies
2. Solaris
Hi All,
I replace a sub-mirror of a mirrored volume by using below command:
#metadetach d10(mirror) d11(striped)
#metattach d10 d13(other striped)
With above process I successfully replaced a faulty volume. I want to knoow if the process I followed is right. Or if not, what... (5 Replies)
Discussion started by: naw_deepak
5 Replies
3. Solaris
Hi everyone,
I wanted to ask a question about fmadm and explorer outputs.
Recently found out that an error shows up in fmadm saying "mb is faulty but still in service" so we took an explorer send to Oracle Support. Error led wasn't on but we didn't want to risk the probability.
They came up... (1 Reply)
Discussion started by: royalliege
1 Replies
4. Solaris
Hi,
Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great.
# uname –a
SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4
#df -k
Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies
5. HP-UX
Requirement to remove a faulty mirrored disk from hp-ux LVM
<root@pdwp1s>/etc # vgdisplay -v /dev/vg00
vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0":
The specified path does not correspond to physical volume attached to
this volume group
vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies
6. HP-UX
Hi,
Have mirrored the primary disk to 3 .
Server and OS:
# uname -a
HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license
# model
9000/800/L3000-7x
# strings /etc/lvmtab
/dev/vg00
+F@<
/dev/dsk/c1t2d0
/dev/dsk/c2t2d0
/dev/dsk/c2t0d0
But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies
7. HP-UX
Hello,
I'm new to this forum and as you will see from my question I'm new to UNIX as well.
One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Discussion started by: gjk
16 Replies
8. Shell Programming and Scripting
I have number in file which contains date and serial number:
2013101000.
The last two digits are serial number (00). So maximum of serial number is 100.
After reaching 100 it becomes 00 with incrementing 10 which is day with max 31.
after reaching 31 it becomes 00 and increments 10... (31 Replies)
Discussion started by: Natalie
31 Replies
9. Red Hat
Hi,
How to determine if HBA card in getting faulty from linux host ? any pointers. (2 Replies)
Discussion started by: saurabh84g
2 Replies
10. UNIX for Beginners Questions & Answers
I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply)
-> show faulty
Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
LEARN ABOUT SUNOS
wnn_hinsi.data
wnn_hinsi.data(4) File Formats wnn_hinsi.data(4)
NAME
wnn_hinsi.data - Wnn6 part of speech administration file
SYNOPSIS
/usr/lib/locale/ja/wnn/ja/hinsi.data
DESCRIPTION
hinsi.data is a file that contains information required to administer the main parts of speech.
Numbers are allocated in the order of the parts of speech and composite parts of speech defined in hinsi.data. These numbers are used
when creating dictionary files and part of speech files, when looking up part of speech names by numbers from the client and server, and
looking up the parts of speech in composite parts of speech. Numbers are assigned in ascending order starting at 0.
Only the following operations are allowed for this file: appending new parts of speech or composite parts of speech to the end of the file
and replacing lines consisting of only "@" with definitions of parts of speech or composite parts of speech. NEVER DELETE ENTRIES. "@" is
used to reserve lines in the file in advance when part of speech names have not yet been determined.
The part of speech formats for lines in this file are as follows:
part_of_speech
composite_part_of_speech $ part_of_speech : part_of_speech:...:part_of_speech
All parts of speech appearing in definitions of composite parts of speech must be defined before the composite part of speech can be
defined. There must not be more than one part of speech or composite part of speech with the same name.
Everything on a line following a semicolon (;) is treated as comment and ignored.
Information on this file (looking up part of speech names from part of speech numbers and looking up the structural elements of composite
parts of speech) are provided by the library and can thus be referenced through the client process.
EXAMPLES
Example 1:
[SENTOU] ;Beginning of a sentence
[MEISHI] ;Indicates a noun.
[ICHIDAN]
[ICHIDANMEI]$[ICHIDAN]:[MEISHI] ;A composite part of speech
@
@
NOTES
Information on the main parts of speech must be consistent between all dictionaries and connection information files. Do not edit and
change hinsi.data. (If the file is changed, the meaning of the part of speech numbers in dictionaries and connection information files
created with the old part of speech administration file will change.)
SunOS 5.10 28 May 1998 wnn_hinsi.data(4)