Hi
I'm using Linux, in the directory /root/my
there is a.out. but when I try to run it , the
shell indicate "bash:a.out: command not found"
but I AM working in this directory. if I use
"./a.out" , it works perfectly.
can any body tell me how to do a permanent set up so that
I can use... (5 Replies)
I have a script that I'm trying to shorten (below) by removing repetitive code.
if ]
then
commodity_ndm_done=Y
fi
if ]
then
customer_ndm_done=Y
fi
if ]
then
department_ndm_done=Y
fi
if ]
then
division_ndm_done=Y
fi (3 Replies)
hi,
I am writing c++ code in unix operating system.In that i need to set the environment variable in unix.
suppose previously i have environment variable like path="something" now i need to change the path value to some othervalue . so that some other program will access that path value... (1 Reply)
I'm having an issue when I export within my program. I'm getting the variable name, not the variable value. I have a configuration file (config.txt) that has the values of the variables set as so:
set -a
export ARCHIVEPOSourceDir="/interfaces/po/log /interfaces/po/data"
export... (2 Replies)
Hi,
It is solaris 5.9, and Oracle 10G is the database. If i login as user, and give 'env' command i can see the Oracle environment variables are set.
PATH=/usr/bin:/usr/sbin:/usr/lib:/etc/ssh:/opt/oracle/app/oracle/product/10.2.0/db_1/bin:/opt/oracle/crs/oracle/product/10.2.0/crs_1/bin... (1 Reply)
I set my TERM variable to work with SMIT and everything works fine but when I logged out and log in again I have to set the variable again.
How can I set a permanent variable into the system so it will be as I wish even if a reboot is needed?
I set variables this way:
export VAR=value (7 Replies)
I thought that set and setenv was easy enough to understand until I started experimenting.
I noticed the same problem in a previous thread, so I will use it as an example.
set command gave the following output:
argv ()
cwd /homes/e/ee325328/assignment.2
home /homes/e/ee325328
path ( a... (2 Replies)
I'm writing a script that'll send a time-stamp to my backup server. I create a file with the name of the current date, send it to my server with scp and rm the file from the local computer.
Individually these commands work fine and with a set name the expect scripts also work fine. The problem... (0 Replies)
Hi
Could you please tell me how to set environment variables in Unix ksh.
And how can acess those varibles in shell scripts
( Please give the code with an example)
For my scenario.
We have written number of shell scripts with hard coded username and password.
But if we want to... (1 Reply)
Discussion started by: shyamu544
1 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.8.7pre1 May 2010 IRSEND(1)