Sponsored Content
The Lounge War Stories How not to install fibre links between data centres! Post 302692453 by admin_xor on Monday 27th of August 2012 04:32:12 PM
Old 08-27-2012
"Innovative Fix" Smilie
 

7 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

How to install FreeBSD without loosing my data?

hi. I am newbie in Unix. I wanted to install Free BSD 5.2.1 to my computer which winXp was already installed. But i couldn't. I chose Standard. Then it said you are going to use dos style fdisk partitioning. Then a window displayed begining like this. WARNING: A geometry of 155127/16/63 for... (0 Replies)
Discussion started by: sualcavab
0 Replies

2. Shell Programming and Scripting

4 x fibre cards elimination

Hi, I have variables like mentioned below and want to separate as mentioned in output. var1="4 x fibre cards" var2="2 fibre cards" var3="6 - fibre cards" var4="4 x dual-port" I have variables like this.I want to separate numbers from this and fibre cards from this. output has to be... (4 Replies)
Discussion started by: ajilesh
4 Replies

3. AIX

Install Fibre Card AIX 5.3

Hello, I have two systems that are being prepared to be SAN attached .. can anyone tell me any specific checks I should perform prior to the cards being installed... I am aware of firmware / OS level and relevant drivers, is there anything else? thanks Chris. (8 Replies)
Discussion started by: chlawren
8 Replies

4. Solaris

Hard Links and Soft or Sym links

When loooking at files in a directory using ls, how can I tell if I have a hard link or soft link? (11 Replies)
Discussion started by: Harleyrci
11 Replies

5. AIX

List all the soft links and hard links

Hi I'm logged in as root in an aix box Which command will list all the soft links and hard links present in the server ? (2 Replies)
Discussion started by: newtoaixos
2 Replies

6. Hardware

Fibre Channel HBA recommendations?

We will be buying new Xeon E5-based servers for our datacenter and were wondering which Fibre Channel host bus adapters we should select for these. The choices are Emulex or QLogic (8Gb FC HBAs). Anybody have any recommendations on which is the better choice? Thanks in advance. (1 Reply)
Discussion started by: atahmass
1 Replies

7. AIX

VIOS - fibre adapters not seeing luns

Hi guys, I've been trying to tackle this issue for days and I'm stumped. Hopefully someone can give more light on what else I can do. I have a p7 series box, with dual VIOS and 10 lpars and everything was working fine until I had to move the box to another location in the data centre. Ensured... (16 Replies)
Discussion started by: aixkidbee
16 Replies
flow-receive(1) 					      General Commands Manual						   flow-receive(1)

NAME
flow-receive -- Receive flow data with the NetFlow protocol. SYNOPSIS
flow-receive [-h] [-b big|little] [-C comment] [-d debug_level] [-o output_file] [-S stat_interval] [-V pdu_version] [-z z_level] localip/remoteip/port DESCRIPTION
The flow-receive utility is used to receive flows in NetFlow format. When the remoteip is configured only flows from that exporter will be processed, this is the most secure and recommended configuration. When the localip is configured flow-receive will only process flows sent to the localip IP address. If remoteip is 0 (not configured) flows from any source IP address are accepted. Multiple non aggregated PDU versions may be accepted at once to support Cisco's Catalyst 6500 NetFlow implementation which exports from both the supervisor and MSFC with the same IP address and same port but different export versions. In this case the exports will be stored in the format specified by the -V flag or whichever export type is received first. OPTIONS
-b big|little Byte order of output. -C Comment Add a comment. -d debug_level Enable debugging. -h Display help. -o file Write to file instead of the standard out. -S stat_interval When configured flow-receive will emit a timestamped message on stderr every stat_interval minutes indicating counters such as the number of flows received, packets processed, and lost flows. -V pdu_version Use pdu_version format output. 1 NetFlow version 1 (No sequence numbers, AS, or mask) 5 NetFlow version 5 6 NetFlow version 6 (5+ Encapsulation size) 7 NetFlow version 7 (Catalyst switches) 8.1 NetFlow AS Aggregation 8.2 NetFlow Proto Port Aggregation 8.3 NetFlow Source Prefix Aggregation 8.4 NetFlow Destination Prefix Aggregation 8.5 NetFlow Prefix Aggregation 8.6 NetFlow Destination (Catalyst switches) 8.7 NetFlow Source Destination (Catalyst switches) 8.8 NetFlow Full Flow (Catalyst switches) 8.9 NetFlow ToS AS Aggregation 8.10 NetFlow ToS Proto Port Aggregation 8.11 NetFlow ToS Source Prefix Aggregation 8.12 NetFlow ToS Destination Prefix Aggregation 8.13 NetFlow ToS Prefix Aggregation 8.14 NetFlow ToS Prefix Port Aggregation 1005 Flow-Tools tagged version 5 -z z_level Configure compression level to z_level. 0 is disabled (no compression), 9 is highest compression. EXAMPLES
Listen on port 9800 on any local interface for exports from IP address 10.0.0.1, store the exports in flows flow-receive 0/10.0.0.1/9800 > flows Listen on port 9800 on any local interface from any IP address, display the received flows with flow-print. flow-receive 0/0/9800 | flow-print BUGS
It is not currently possible to convert between the aggregated formats (8.x) and the non aggregated formats (1,5,6,7). AUTHOR
Mark Fullmer maf@splintered.net SEE ALSO
flow-tools(1) flow-receive(1)
All times are GMT -4. The time now is 07:36 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy