Sponsored Content
Full Discussion: adding LUN to linux server
Operating Systems Linux Red Hat adding LUN to linux server Post 302624861 by abhay1983 on Tuesday 17th of April 2012 01:33:47 AM
Old 04-17-2012
Thanks all for your valuable comments ...
catch u later in another query ...

Chrees Smilie
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Finding SAN Lun's on Linux.

Am trying to differentiate between the local disks and LUN's presented from SAN onto the server. Have Tried fdisk -l, however I quite cudn't differentiate the local disks from SAN presented LUN's. Can you pls. let me know the procedure and commands to find this. OS - RHEL 4 SAN - EMC... (3 Replies)
Discussion started by: Crazy_murli
3 Replies

2. Solaris

LUN allocation in solaris server

hi all can anyone tell me how to track a new attached LUN in a solaris server?? (3 Replies)
Discussion started by: raynu.sharma
3 Replies

3. Red Hat

Grow LUN presented on Linux host

Hi, I have a SAN LUN of 550 GB created as an ext3 partition of the entire lun and need to make the lun and partition larger... 600 GB # fdisk -l /dev/sdj Disk /dev/sdj: 590.5 GB, 590558003200 bytes 255 heads, 63 sectors/track, 71797 cylinders Units = cylinders of 16065 * 512 = 8225280... (3 Replies)
Discussion started by: jamba1
3 Replies

4. Solaris

Solaris 10, adding new LUN from SAN storage

Hello to all, Actually, currently on my Solaris box, I've a LUN (5TB space) from a EMC storage which is working fine, and a partition with ZFS filesystem is created for that LUN. as further you'll see in the logs, the "c4t6006016053802E00E6A9196B6506E211d0s2" is the current configured LUN in the... (4 Replies)
Discussion started by: Anti_Evil
4 Replies

5. Red Hat

DM multipath :iscsi lun shows by diff names on two server where its exported

Hi, I am trying to setup multipathing (using DM multipath) for a redhat cluster setup ...all setup is done but issue is : node 1 shows the shared iscsi lun as sdc node 2 shows the same as sdg (changes on reboots) Due to this (i guess) i get i/o error & i can not read files created by... (0 Replies)
Discussion started by: heman96
0 Replies

6. Linux

How to detect FC lun on Server?

I have created a lun on Storage and connected it to server using fiber channel. LUN is presented on new Server . How do i check and mount this newly created LUN? (1 Reply)
Discussion started by: pinga123
1 Replies

7. UNIX for Advanced & Expert Users

Linux Thin Lun space reclamation

Hello, We have IBM storwize v7000 storage. I have created thin provisioned LUN and attached it to my server(dell r910, Centos 7). Whenever I copy files in that LUN correspondingly Thin provisioned LUN's used space increases but when I remove files to free up space the LUN's size isn't... (5 Replies)
Discussion started by: Vit0_Corleone
5 Replies

8. Post Here to Contact Site Administrators and Moderators

AIX server do not detect LUN from HP storage

ssssssssssss (0 Replies)
Discussion started by: sampathenjoy
0 Replies

9. Linux

Mount a newly added LUN on a GNU/Linux distro

Hi I am not familiar with the linux, but I was asked to create a file system on a LUN from the NetApp that was mapped to the linux server. The server is runing: uname -a Linux localhost.localdomain 2.6.18-92.el5 #1 SMP Tue Apr 29 13:16:15 EDT 2008 x86_64 x86_64 x86_64 GNU/Linux and now... (6 Replies)
Discussion started by: fretagi
6 Replies

10. Red Hat

Move a LUN from one server to the other

I have NetApp LUN that was presented to a Red Hat Enterprise Linux Server release 5.7 (Tikanga) machine. But this LUN has already data, because it was being used on another server. I can see the new LUN when running fdisk: fdisk -l | egrep '^Disk' | egrep -v 'dm-' | grep -v identifier Disk... (15 Replies)
Discussion started by: fretagi
15 Replies
SG_RDAC(8)							     SG3_UTILS								SG_RDAC(8)

NAME
sg_rdac - Display or Modify RDAC Redundant Controller Page SYNOPSIS
sg_rdac [-a] [-f=LUN] [-v] [-V] DEVICE DESCRIPTION
sg_rdac displays or modifies the RDAC controller settings via the Redundant Controller Page (0x2C). When modifying the settings it allows to transfer the ownership of individual drives to the controller the command was received on. OPTIONS
-a Transfer all (visible) devices -f=LUN Transfer the device identified by LUN. This command will only work if the controller supports 'Dual Active Mode' (aka active/active mode). -v be verbose -V print version string then exit EXIT STATUS
The exit status of sg_rdac is 0 when it is successful. Otherwise see the sg3_utils(8) man page. AUTHOR
Written by Hannes Reinecke <hare at suse dot com>, based on sg_emc_trespass. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2006-2007 Hannes Reinecke, Douglas Gilbert. This software is distributed under the GPL version 2. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. sg3_utils-1.23 January 2007 SG_RDAC(8)
All times are GMT -4. The time now is 10:32 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy