Sponsored Content
Operating Systems Linux Red Hat How to Find what HBA is configured on Linux? Post 302511248 by sixstrings on Wednesday 6th of April 2011 09:48:08 AM
Old 04-06-2011
Quote:
Originally Posted by mark54g
The LUN number is a harder one, but here's what you can do:

You can scan for new luns the following way:

Code:
for i in /sys/class/scsi_host/host*
do
echo '- - -' > $i
done

actually, you need to add the scan file in this code

Code:
for i in /sys/class/scsi_host/host*
do
echo '- - -' > ${i}/scan
done

Without the scan part, you are echoing the --- into the directory and it will not scan the luns.
This User Gave Thanks to sixstrings For This Post:
 

10 More Discussions You Might Find Interesting

1. Slackware

LDAP not getting configured!!!

hi, i m tryin to learn ldap. but its not getting configured. the error msg it shows is: LDAP configure error: BDB/HDB : Berkeley DB version incompatibe. The BDB version i have installed is bdb4.2.52 and the ldap version is openldap-2.3.12. my machine is running on red hat linux 9. Why... (1 Reply)
Discussion started by: mridula
1 Replies

2. UNIX for Advanced & Expert Users

Configured sftp still requires password

Hi Gurus:) I have to connect from a SunOS 5.10 to a 5.8 using sftp in BatchMode. For this, I have generated a Public-Key (ssh-keygen -b 1024 -P "" -t dsa) on the 5.10 and saved it in ~remote-user/.ssh/authorized-keys on the 5.8. Then, running either one of ssh or sftp, it asks for the... (24 Replies)
Discussion started by: unilover
24 Replies

3. UNIX for Dummies Questions & Answers

How to find which raid is configured(without restart)

Is there a way to find the raid type without restarting the machine? I m using linux operating system. (3 Replies)
Discussion started by: pinga123
3 Replies

4. UNIX for Dummies Questions & Answers

What are the two ways the hardware clock can be configured under Linux?

What are the two ways the hardware clock can be configured under Linux? Thanks (3 Replies)
Discussion started by: lemon_06
3 Replies

5. Solaris

How to enable hba port of a two port hba card

Hi, i have a two port hba card in solaris 10 system one of which is disabled. How to enable and configure the other port. ---------- Post updated at 08:17 AM ---------- Previous update was at 03:40 AM ---------- please help :( (7 Replies)
Discussion started by: rishiraaz
7 Replies

6. HP-UX

Script to find what netprinters are configured with what model

Following this thread : https://www.unix.com/hp-ux/189023-solved-way-tell-printer-used-configured-print-queue.html This is rwuerth's nice contribution! I had a more complicated script written a long time ago to find out this information, but after realizing due to VBE's post (thank you VBE)... (0 Replies)
Discussion started by: rwuerth
0 Replies

7. UNIX for Dummies Questions & Answers

Show HBA WWN on AIX & Linux

Hi all, I have an environment with Aix and Linux severs zoned to tape drives I'd like to list HBAs WWN on my servers which are zoned to the drives. Thanks (1 Reply)
Discussion started by: Sara_84
1 Replies

8. IP Networking

IP not configured is being used to login

Hi have a solaris server with the following IP 192.168.0.85, but anybody can login in using 172.19.0.85, and the ifconfigcommand does not show the 172.19.05 . # ifconfig -a lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1 inet 127.0.0.1 netmask... (6 Replies)
Discussion started by: fretagi
6 Replies

9. Solaris

How to find port number wwn of particular port on dual port HBA,?

please find the below o/p for your reference bash-3.00# fcinfo hba-port HBA Port WWN: 21000024ff295a34 OS Device Name: /dev/cfg/c2 Manufacturer: QLogic Corp. Model: 375-3356-02 Firmware Version: 05.03.02 FCode/BIOS Version: BIOS: 2.02; fcode: 2.01;... (3 Replies)
Discussion started by: sb200
3 Replies

10. Debian

Dhcp not getting configured on Ubuntu

I have kali running on vbox as :- /etc/network/interfaces ifup eth0 gives me tpcdump (0 Replies)
Discussion started by: lazerz
0 Replies
SMARTPQI(4)						     Linux Programmer's Manual						       SMARTPQI(4)

NAME
smartpqi - Microsemi Smart Family SCSI driver SYNOPSIS
modprobe smartpqi [disable_device_id_wildcards={0|1}] [disable_heartbeat={0|1}] [disable_ctrl_shutdown={0|1}] [lockup_action={none|reboot|panic}] DESCRIPTION
smartpqi is a SCSI driver for Microsemi Smart Family controllers. Supported ioctl() operations For compatibility with applications written for the cciss(4) and hpsa(4) drivers, many, but not all of the ioctl(2) operations supported by the hpsa driver are also supported by the smartpqi driver. The data structures used by these operations are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These operations all do exactly the same thing, which is to cause the driver to re-scan for new devices. This does exactly the same thing as writing to the smartpqi-specific host rescan attribute. CCISS_GETPCIINFO This operation Returns the PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER This operation returns the driver version in four bytes, encoded as: (major_version << 28) | (minor_version << 24) | (release << 16) | revision CCISS_PASSTHRU Allows BMIC and CISS commands to be passed through to the controller. Boot options disable_device_id_wildcards={0|1} Disables support for device ID wildcards. The default value is 0. disable_heartbeat={0|1} Disables support for the controller's heartbeat check. This parameter is used for debugging purposes. The default value is 0, leaving the controller's heartbeat check active. disable_ctrl_shutdown={0|1} Disables support for shutting down the controller in the event of a controller lockup. The default value is 0. lockup_action={none|reboot|panic} Specifies the action the driver takes when a controller lockup is detected. The default action is none. parameter action --------------------------------------------- none take controller offline only reboot reboot the system panic panic the system FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd), tape drives via the SCSI tape driver (st), and the RAID controller via the SCSI generic driver (sg), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. SmartPQI-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan The host rescan attribute is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives) and notify the SCSI mid-layer of any changes detected. Usually this action is triggered automatically by configuration changes, so the user should not normally have to write to this file. Doing so may be useful when hot-plugging devices such as tape drives or entire storage boxes containing pre- configured logical drives. /sys/class/scsi_host/host*/version The host version attribute is a read-only attribute. This attribute contains the driver version and the controller firmware ver- sion. For example: $ cat /sys/class/scsi_host/host1/version driver: 1.1.2-126 firmware: 1.29-112 /sys/class/scsi_host/host*/lockup_action The host lockup_action attribute is a read/write attribute. This attribute will cause the driver to perform a specific action in the unlikely event that a controller lockup has been detected. See OPTIONS above for an explanation of the lockup_action values. SmartPQI-specific disk attribute files in /sys In the file specifications below, c stands for the number of the appropriate SCSI controller, b is the bus number, t the target number, and l is the logical unit number (LUN). /sys/class/scsi_disk/c:b:t:l/device/raid_level The raid_level attribute is read-only. This attribute contains the RAID level of each logical drive. For example: $ cat /sys/class/scsi_disk/4:0:0:0/device/raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/sas_address The sas_address attribute is read-only. This attribute contains the unique identifier of the disk. For example: $ cat /sys/class/scsi_disk/1:0:3:0/device/sas_address 0x5001173d028543a2 /sys/class/scsi_disk/c:b:t:l/device/ssd_smart_path_enabled The ssd_smart_path_enabled attribute is read-only. This attribute is for ioaccel-enabled volumes. (Ioaccel is an alternative driver submission path that allows the driver to send I/O requests directly to backend SCSI devices, bypassing the controller firmware. This results in an increase in performance. This method is used for HBA disks and for logical volumes comprised of SSDs.) Contains 1 if ioaccel is enabled for the volume and 0 otherwise. For example: $ cat /sys/class/scsi_disk/1:0:3:0/device/ssd_smart_path_enabled 0 VERSIONS
The smarpqi driver was added in Linux 4.9. NOTES
Configuration To configure a Microsemi Smart Family controller, refer to the User Guide for the controller, which can be found by searching for the spe- cific controller at <https://storage.microsemi.com/>. SEE ALSO
cciss(4), hpsa(4), sd(4), st(4) Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree. Linux 2017-10-19 SMARTPQI(4)
All times are GMT -4. The time now is 08:53 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy