The LUN number is a harder one, but here's what you can do:

You can scan for new luns the following way:

Code:
for i in /sys/class/scsi_host/host*
do
echo '- - -' > $i
done

for the type of HBA:

Code:
for i in /sys/class/scsi_host/host*
do
cat $i/model_name; cat $i/model_desc; cat $i/
done

This User Gave Thanks to mark54g For This Post:
 

10 More Discussions You Might Find Interesting

1. Slackware

LDAP not getting configured!!!

hi, i m tryin to learn ldap. but its not getting configured. the error msg it shows is: LDAP configure error: BDB/HDB : Berkeley DB version incompatibe. The BDB version i have installed is bdb4.2.52 and the ldap version is openldap-2.3.12. my machine is running on red hat linux 9. Why... (1 Reply)
Discussion started by: mridula
1 Replies

2. UNIX for Advanced & Expert Users

Configured sftp still requires password

Hi Gurus:) I have to connect from a SunOS 5.10 to a 5.8 using sftp in BatchMode. For this, I have generated a Public-Key (ssh-keygen -b 1024 -P "" -t dsa) on the 5.10 and saved it in ~remote-user/.ssh/authorized-keys on the 5.8. Then, running either one of ssh or sftp, it asks for the... (24 Replies)
Discussion started by: unilover
24 Replies

3. UNIX for Dummies Questions & Answers

How to find which raid is configured(without restart)

Is there a way to find the raid type without restarting the machine? I m using linux operating system. (3 Replies)
Discussion started by: pinga123
3 Replies

4. UNIX for Dummies Questions & Answers

What are the two ways the hardware clock can be configured under Linux?

What are the two ways the hardware clock can be configured under Linux? Thanks (3 Replies)
Discussion started by: lemon_06
3 Replies

5. Solaris

How to enable hba port of a two port hba card

Hi, i have a two port hba card in solaris 10 system one of which is disabled. How to enable and configure the other port. ---------- Post updated at 08:17 AM ---------- Previous update was at 03:40 AM ---------- please help :( (7 Replies)
Discussion started by: rishiraaz
7 Replies

6. HP-UX

Script to find what netprinters are configured with what model

Following this thread : https://www.unix.com/hp-ux/189023-solved-way-tell-printer-used-configured-print-queue.html This is rwuerth's nice contribution! I had a more complicated script written a long time ago to find out this information, but after realizing due to VBE's post (thank you VBE)... (0 Replies)
Discussion started by: rwuerth
0 Replies

7. UNIX for Dummies Questions & Answers

Show HBA WWN on AIX & Linux

Hi all, I have an environment with Aix and Linux severs zoned to tape drives I'd like to list HBAs WWN on my servers which are zoned to the drives. Thanks (1 Reply)
Discussion started by: Sara_84
1 Replies

8. IP Networking

IP not configured is being used to login

Hi have a solaris server with the following IP 192.168.0.85, but anybody can login in using 172.19.0.85, and the ifconfigcommand does not show the 172.19.05 . # ifconfig -a lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1 inet 127.0.0.1 netmask... (6 Replies)
Discussion started by: fretagi
6 Replies

9. Solaris

How to find port number wwn of particular port on dual port HBA,?

please find the below o/p for your reference bash-3.00# fcinfo hba-port HBA Port WWN: 21000024ff295a34 OS Device Name: /dev/cfg/c2 Manufacturer: QLogic Corp. Model: 375-3356-02 Firmware Version: 05.03.02 FCode/BIOS Version: BIOS: 2.02; fcode: 2.01;... (3 Replies)
Discussion started by: sb200
3 Replies

10. Debian

Dhcp not getting configured on Ubuntu

I have kali running on vbox as :- /etc/network/interfaces ifup eth0 gives me tpcdump (0 Replies)
Discussion started by: lazerz
0 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Since Linux 4.14, the following Smart Array boards are also supported: Smart Array 5300 Smart Array 5312 Smart Array 532 Smart Array 5i Smart Array 6400 Smart Array 6400 EM Smart Array 641 Smart Array 642 Smart Array 6i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Smart Array P400 Smart Array P400i Smart Array P600 Smart Array P700m Smart Array P800 Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the latest version of this page, can be found at https://www.kernel.org/doc/man-pages/. Linux 2017-09-15 HPSA(4)
All times are GMT -4. The time now is 02:38 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy