07-09-2010
Hi
it's link
/opt/oracle/product/10.2/lib32 and /opt/oracle/product/10.2/lib
you rather look for /opt/oracle/product/10.2/lib64
please look,
error 0509-036
This User Gave Thanks to john1212 For This Post:
9 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Anyone:
I have a very annoying problem on one of our servers (running Solaris 8). when ever I try to run "xhost +" with the display set at "localhost:0.0" I get the following error:
xhost +
Xlib: connection to "finappprod:0.0" refused by server
Xlib: Invalid... (1 Reply)
Discussion started by: errolg
1 Replies
2. UNIX for Advanced & Expert Users
Hi,
when installing a piece of third part software I get the error "Bad magic number" at one point when it tries to use libraries from the bea tuxedo server. Am I correct that this means that the software is expecting 32bit while I'm on 64bit? Is there a way around it or can it only be solved... (5 Replies)
Discussion started by: rein
5 Replies
3. Shell Programming and Scripting
In one of our internal scripts (unix.run), I have noticed that the following shebang.
#!/bin/sh -
for i in test1 test2 test3 ; do
.
.
.
Any idea what the - in the magic number stands for ?
And what impact does it have on the script ?
Continuing on the same script, I have the... (3 Replies)
Discussion started by: vino
3 Replies
4. Filesystems, Disks and Memory
Dear All,
i have a SCSI hard disk drive i'm installing on it solaris 5 and the workstation is sun sparc, i made an image of this H.D using Norton Ghost 6, so i took off the SCSI H.D from the sun workstation and put it on a Compaq server then i booted the server from the Norton Ghost floppy disk... (0 Replies)
Discussion started by: wesweshahaha
0 Replies
5. Solaris
/pci@if,0/pci@1,1/ide@3/dad@0,0 corrupt label wrong magic number
can u plz suggustion me (6 Replies)
Discussion started by: tirupathi
6 Replies
6. Solaris
I'll keep it fairly straight forward. I work with a Solaris server and magically today it decided to take a dump on me. At first it give a long list of files that couldn't be acessed before terminating the boot process and returning to the 'ok' prompt. Booting in single-user mode allowed me to run... (4 Replies)
Discussion started by: Aon
4 Replies
7. Web Development
I have Apache v2.0.63 on Solaris 10 (x86 on VM). While starting the apache server, facing the following exception -
Invalid command 'Order', perhaps misspelled or defined by a module not included in the server configuration
Googling says to add the entry LoadModule authz_host_module... (0 Replies)
Discussion started by: poga
0 Replies
8. UNIX for Dummies Questions & Answers
I have open suse kernel kernel 3.1.0-1.2-desktop on which I used kernel source 3.1.10-1.2 downloaded from kernel.org.
The module gets built.
While loading a kernel module I am getting Invalid module format error with description "first_driver: no symbol version for module_layout"
The... (5 Replies)
Discussion started by: rupeshkp728
5 Replies
9. Solaris
hi . my " /usr " was full ,so i went into the failsafe mode in solaris 10 and used format utilily to adjust space for it and labeled it. But after that whenever i try to boot solaris normally ,it is giving "magic number error"
I tried
fsck -o b=32 /dev/dsk/c0d0s6 (for /usr)
newfs -N... (6 Replies)
Discussion started by: tushardul
6 Replies
LEARN ABOUT DEBIAN
plmesh
PLMESH(3plplot) PLplot API PLMESH(3plplot)
NAME
plmesh - Plot surface mesh
SYNOPSIS
plmesh(x, y, z, nx, ny, opt)
DESCRIPTION
Plots a surface mesh within the environment set up by plw3d(3plplot). The surface is defined by the two-dimensional array z[nx][ny], the
point z[i][j] being the value of the function at (x[i], y[j]). Note that the points in arrays x and y do not need to be equally spaced,
but must be stored in ascending order. The parameter opt controls the way in which the surface is displayed. For further details see the
PLplot documentation.
Redacted form: plmesh(x, y, z, opt)
This function is used in example 11.
ARGUMENTS
x (PLFLT *, input)
Pointer to set of x coordinate values at which the function is evaluated.
y (PLFLT *, input)
Pointer to set of y coordinate values at which the function is evaluated.
z (PLFLT **, input)
Pointer to a vectored two-dimensional array with set of function values.
nx (PLINT, input)
Number of x values at which function is evaluated.
ny (PLINT, input)
Number of y values at which function is evaluated.
opt (PLINT, input)
Determines the way in which the surface is represented: opt=DRAW_LINEX: Lines are drawn showing z as a function of x for each value
of y[j]. opt=DRAW_LINEY: Lines are drawn showing z as a function of y for each value of x[i]. opt=DRAW_LINEXY: Network of lines is
drawn connecting points at which function is defined.
AUTHORS
Geoffrey Furnish and Maurice LeBrun wrote and maintain PLplot. This man page was automatically generated from the DocBook source of the
PLplot documentation, maintained by Alan W. Irwin and Rafael Laboissiere.
SEE ALSO
PLplot documentation at http://plplot.sourceforge.net/resources.