Sponsored Content
Full Discussion: T5220 server
Operating Systems Solaris T5220 server Post 302395752 by rajasekg on Tuesday 16th of February 2010 11:37:50 PM
Old 02-17-2010
T5220 Server

prtdiag -v |more
System Configuration: Sun Microsystems sun4v SPARC Enterprise T5220
Memory size: 65408 Megabytes

================================ Virtual CPUs ================================


CPU ID Frequency Implementation Status
------ --------- ---------------------- -------
0 1165 MHz SUNW,UltraSPARC-T2 on-line
1 1165 MHz SUNW,UltraSPARC-T2 on-line
2 1165 MHz SUNW,UltraSPARC-T2 on-line
3 1165 MHz SUNW,UltraSPARC-T2 on-line
4 1165 MHz SUNW,UltraSPARC-T2 on-line
5 1165 MHz SUNW,UltraSPARC-T2 on-line
6 1165 MHz SUNW,UltraSPARC-T2 on-line
7 1165 MHz SUNW,UltraSPARC-T2 on-line
8 1165 MHz SUNW,UltraSPARC-T2 on-line
9 1165 MHz SUNW,UltraSPARC-T2 on-line
10 1165 MHz SUNW,UltraSPARC-T2 on-line
11 1165 MHz SUNW,UltraSPARC-T2 on-line
12 1165 MHz SUNW,UltraSPARC-T2 on-line
13 1165 MHz SUNW,UltraSPARC-T2 on-line
--More--

bash-3.00# prtdiag -v |more     
System Configuration: Sun Microsystems sun4v SPARC Enterprise T5220
Memory size: 65408 Megabytes

================================ Virtual CPUs ================================


CPU ID Frequency Implementation Status
------ --------- ---------------------- -------
0 1165 MHz SUNW,UltraSPARC-T2 on-line
1 1165 MHz SUNW,UltraSPARC-T2 on-line
2 1165 MHz SUNW,UltraSPARC-T2 on-line
3 1165 MHz SUNW,UltraSPARC-T2 on-line
4 1165 MHz SUNW,UltraSPARC-T2 on-line
5 1165 MHz SUNW,UltraSPARC-T2 on-line
6 1165 MHz SUNW,UltraSPARC-T2 on-line
7 1165 MHz SUNW,UltraSPARC-T2 on-line
8 1165 MHz SUNW,UltraSPARC-T2 on-line
9 1165 MHz SUNW,UltraSPARC-T2 on-line
10 1165 MHz SUNW,UltraSPARC-T2 on-line
11 1165 MHz SUNW,UltraSPARC-T2 on-line
12 1165 MHz SUNW,UltraSPARC-T2 on-line
13 1165 MHz SUNW,UltraSPARC-T2 on-line
14 1165 MHz SUNW,UltraSPARC-T2 on-line
15 1165 MHz SUNW,UltraSPARC-T2 on-line
16 1165 MHz SUNW,UltraSPARC-T2 on-line
17 1165 MHz SUNW,UltraSPARC-T2 on-line
18 1165 MHz SUNW,UltraSPARC-T2 on-line
19 1165 MHz SUNW,UltraSPARC-T2 on-line
20 1165 MHz SUNW,UltraSPARC-T2 on-line
21 1165 MHz SUNW,UltraSPARC-T2 on-line
22 1165 MHz SUNW,UltraSPARC-T2 on-line
23 1165 MHz SUNW,UltraSPARC-T2 on-line
24 1165 MHz SUNW,UltraSPARC-T2 on-line
25 1165 MHz SUNW,UltraSPARC-T2 on-line
26 1165 MHz SUNW,UltraSPARC-T2 on-line
27 1165 MHz SUNW,UltraSPARC-T2 on-line
28 1165 MHz SUNW,UltraSPARC-T2 on-line
29 1165 MHz SUNW,UltraSPARC-T2 on-line
30 1165 MHz SUNW,UltraSPARC-T2 on-line
31 1165 MHz SUNW,UltraSPARC-T2 on-line
32 1165 MHz SUNW,UltraSPARC-T2 on-line
33 1165 MHz SUNW,UltraSPARC-T2 on-line
34 1165 MHz SUNW,UltraSPARC-T2 on-line
35 1165 MHz SUNW,UltraSPARC-T2 on-line
36 1165 MHz SUNW,UltraSPARC-T2 on-line
37 1165 MHz SUNW,UltraSPARC-T2 on-line
38 1165 MHz SUNW,UltraSPARC-T2 on-line
39 1165 MHz SUNW,UltraSPARC-T2 on-line
40 1165 MHz SUNW,UltraSPARC-T2 on-line
41 1165 MHz SUNW,UltraSPARC-T2 on-line
42 1165 MHz SUNW,UltraSPARC-T2 on-line
43 1165 MHz SUNW,UltraSPARC-T2 on-line
44 1165 MHz SUNW,UltraSPARC-T2 on-line
45 1165 MHz SUNW,UltraSPARC-T2 on-line
46 1165 MHz SUNW,UltraSPARC-T2 on-line
47 1165 MHz SUNW,UltraSPARC-T2 on-line
48 1165 MHz SUNW,UltraSPARC-T2 on-line
49 1165 MHz SUNW,UltraSPARC-T2 on-line
50 1165 MHz SUNW,UltraSPARC-T2 on-line
51 1165 MHz SUNW,UltraSPARC-T2 on-line
52 1165 MHz SUNW,UltraSPARC-T2 on-line
53 1165 MHz SUNW,UltraSPARC-T2 on-line
54 1165 MHz SUNW,UltraSPARC-T2 on-line
55 1165 MHz SUNW,UltraSPARC-T2 on-line
56 1165 MHz SUNW,UltraSPARC-T2 on-line
57 1165 MHz SUNW,UltraSPARC-T2 on-line
58 1165 MHz SUNW,UltraSPARC-T2 on-line
59 1165 MHz SUNW,UltraSPARC-T2 on-line
60 1165 MHz SUNW,UltraSPARC-T2 on-line
61 1165 MHz SUNW,UltraSPARC-T2 on-line
62 1165 MHz SUNW,UltraSPARC-T2 on-line
63 1165 MHz SUNW,UltraSPARC-T2 on-line

======================= Physical Memory Configuration ========================
Segment Table:
--------------------------------------------------------------
Base Segment Interleave Bank Contains
Address Size Factor Size Modules
--------------------------------------------------------------
0x0 64 GB 8 8 GB MB/CMP0/BR0/CH0/D0
MB/CMP0/BR0/CH1/D0
8 GB MB/CMP0/BR0/CH0/D1
MB/CMP0/BR0/CH1/D1
8 GB MB/CMP0/BR1/CH0/D0
MB/CMP0/BR1/CH1/D0
8 GB MB/CMP0/BR1/CH0/D1
MB/CMP0/BR1/CH1/D1
8 GB MB/CMP0/BR2/CH0/D0
MB/CMP0/BR2/CH1/D0
8 GB MB/CMP0/BR2/CH0/D1
MB/CMP0/BR2/CH1/D1
8 GB MB/CMP0/BR3/CH0/D0
MB/CMP0/BR3/CH1/D0
8 GB MB/CMP0/BR3/CH0/D1
MB/CMP0/BR3/CH1/D1


================================ IO Devices ================================
Slot + Bus Name + Model
Status Type Path
----------------------------------------------------------------------------
MB/NET0 PCIE network-pciex8086,105e
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0
MB/NET1 PCIE network-pciex8086,105e
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0,1
MB/NET2 PCIE network-pciex8086,105e
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0
MB/NET3 PCIE network-pciex8086,105e
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0,1
MB/SASHBA PCIE scsi-pciex1000,58 LSI,1068E
/pci@0/pci@0/pci@2/scsi@0
MB/RISER0/PCIE0 PCIE network-pciex108e,abcd SUNW,pcie-qgc
/pci@0/pci@0/pci@8/pci@0/pci@9/network@0
MB/RISER0/PCIE0 PCIE network-pciex108e,abcd SUNW,pcie-qgc
/pci@0/pci@0/pci@8/pci@0/pci@9/network@0,1
MB/RISER0/PCIE0 PCIE network-pciex108e,abcd SUNW,pcie-qgc
/pci@0/pci@0/pci@8/pci@0/pci@9/network@0,2
MB/RISER0/PCIE0 PCIE network-pciex108e,abcd SUNW,pcie-qgc
/pci@0/pci@0/pci@8/pci@0/pci@9/network@0,3
MB PCIX usb-pciclass,0c0310
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0
MB PCIX usb-pciclass,0c0310
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,1
MB PCIX usb-pciclass,0c0320
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2

============================ Environmental Status ============================
Fan sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/FANBD0/FM0/F0 TACH ok
SYS/FANBD0/FM0/F1 TACH ok
SYS/FANBD0/FM1/F0 TACH ok
SYS/FANBD0/FM1/F1 TACH ok
SYS/FANBD0/FM2/F0 TACH ok
SYS/FANBD0/FM2/F1 TACH ok

Fan indicators:
------------------------------------------------------------
Location Sensor Condition
------------------------------------------------------------
SYS/PS0 FAN_FAULT ok
SYS/PS1 FAN_FAULT ok

Temperature sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/MB T_AMB ok
SYS/MB/CMP0/BR0/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR0/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR0/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR0/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR1/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR1/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR2/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR2/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR3/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR3/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH1/D1 T_AMB ok
SYS/MB/CMP0 T_TCORE ok
SYS/MB/CMP0 T_BCORE ok

Temperature indicators:
------------------------------------------------------------
Location Indicator Condition
------------------------------------------------------------
SYS/PS0 TEMP_FAULT ok
SYS/PS1 TEMP_FAULT ok

Current sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/PS0 I_IN_MAIN ok
SYS/PS0 I_IN_LIMIT ok
SYS/PS0 I_OUT_MAIN ok
SYS/PS0 I_OUT_LIMIT ok
SYS/PS1 I_IN_MAIN disabled
SYS/PS1 I_IN_LIMIT disabled
SYS/PS1 I_OUT_MAIN disabled
SYS/PS1 I_OUT_LIMIT disabled

Current indicators:
------------------------------------------------------------
Location Indicator Condition
------------------------------------------------------------
SYS/MB I_USB0 ok
SYS/MB I_USB1 ok
SYS/PS0 CUR_FAULT ok
SYS/PS1 CUR_FAULT ok

Voltage sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/MB V_VMEML ok
SYS/MB V_VMEMR ok
SYS/MB V_+3V3_STBY ok
SYS/MB V_VCORE ok
SYS/MB V_+3V3_MAIN ok
SYS/MB V_VDDIO ok
SYS/MB V_+12V0_MAIN ok
SYS/MB V_VBAT ok
SYS/PS0 V_IN_MAIN ok
SYS/PS0 V_OUT_MAIN ok
SYS/PS1 V_IN_MAIN disabled
SYS/PS1 V_OUT_MAIN disabled

Voltage indicators:
------------------------------------------------------------
Location Indicator Condition
------------------------------------------------------------
SYS/MB VCORE_POK ok
SYS/MB VMEML_POK ok
SYS/MB VMEMR_POK ok
SYS/PS0 AC_POK ok
SYS/PS0 DC_POK ok
SYS/PS0 VOLT_FAULT ok
SYS/PS1 AC_POK fail
SYS/PS1 DC_POK fail
SYS/PS1 VOLT_FAULT ok

LEDs:
------------------------------------------------------------
Location LED State
------------------------------------------------------------
SYS SERVICE off
SYS LOCATE off
SYS ACT steady
SYS PS_FAULT off
SYS TEMP_FAULT off
SYS FAN_FAULT off
SYS/MB/CMP0/BR0/CH0/D0 SERVICE off
SYS/MB/CMP0/BR0/CH0/D1 SERVICE off
SYS/MB/CMP0/BR0/CH1/D0 SERVICE off
SYS/MB/CMP0/BR0/CH1/D1 SERVICE off
SYS/MB/CMP0/BR1/CH0/D0 SERVICE off
SYS/MB/CMP0/BR1/CH0/D1 SERVICE off
SYS/MB/CMP0/BR1/CH1/D0 SERVICE off
SYS/MB/CMP0/BR1/CH1/D1 SERVICE off
SYS/MB/CMP0/BR2/CH0/D0 SERVICE off
SYS/MB/CMP0/BR2/CH0/D1 SERVICE off
SYS/MB/CMP0/BR2/CH1/D0 SERVICE off
SYS/MB/CMP0/BR2/CH1/D1 SERVICE off
SYS/MB/CMP0/BR3/CH0/D0 SERVICE off
SYS/MB/CMP0/BR3/CH0/D1 SERVICE off
SYS/MB/CMP0/BR3/CH1/D0 SERVICE off
SYS/MB/CMP0/BR3/CH1/D1 SERVICE off
SYS/HDD0 SERVICE off
SYS/HDD0 OK2RM off
SYS/HDD1 SERVICE off
SYS/HDD1 OK2RM off
SYS/HDD2 SERVICE off
SYS/HDD2 OK2RM off
SYS/HDD3 SERVICE off
SYS/HDD3 OK2RM off
SYS/HDD4 SERVICE off
SYS/HDD4 OK2RM off
SYS/HDD5 SERVICE off
SYS/HDD5 OK2RM off
SYS/HDD6 SERVICE off
SYS/HDD6 OK2RM off
SYS/HDD7 SERVICE off
SYS/HDD7 OK2RM off
SYS/FANBD0/FM0 SERVICE off
SYS/FANBD0/FM1 SERVICE off
SYS/FANBD0/FM2 SERVICE off

============================ FRU Status ============================
Location Name Status
------------------------------------------------------
SYS MB enabled
SYS/MB RISER0 enabled
SYS/MB RISER1 enabled
SYS/MB RISER2 enabled
SYS/MB SCC_NVRAM enabled
SYS/MB/CMP0/BR0/CH0 D0 enabled
SYS/MB/CMP0/BR0/CH0 D1 enabled
SYS/MB/CMP0/BR0/CH1 D0 enabled
SYS/MB/CMP0/BR0/CH1 D1 enabled
SYS/MB/CMP0/BR1/CH0 D0 enabled
SYS/MB/CMP0/BR1/CH0 D1 enabled
SYS/MB/CMP0/BR1/CH1 D0 enabled
SYS/MB/CMP0/BR1/CH1 D1 enabled
SYS/MB/CMP0/BR2/CH0 D0 enabled
SYS/MB/CMP0/BR2/CH0 D1 enabled
SYS/MB/CMP0/BR2/CH1 D0 enabled
SYS/MB/CMP0/BR2/CH1 D1 enabled
SYS/MB/CMP0/BR3/CH0 D0 enabled
SYS/MB/CMP0/BR3/CH0 D1 enabled
SYS/MB/CMP0/BR3/CH1 D0 enabled
SYS/MB/CMP0/BR3/CH1 D1 enabled
SYS HDD0 enabled
SYS HDD1 enabled
SYS HDD2 enabled
SYS HDD3 enabled
SYS HDD4 enabled
SYS HDD5 enabled
SYS HDD6 enabled
SYS HDD7 enabled
SYS PDB enabled
SYS PADCRD enabled
SYS SASBP enabled
SYS DVD enabled
SYS USBBD enabled
SYS FANBD0 enabled
SYS/FANBD0 FM0 enabled
SYS/FANBD0 FM1 enabled
SYS/FANBD0 FM2 enabled
SYS FANBD1 enabled
SYS PS0 enabled
SYS PS1 enabled

============================ FW Version ============================
Version
------------------------------------------------------------
Sun System Firmware 7.2.2.e 2009/06/19 10:22


====================== System PROM revisions =======================
Version
------------------------------------------------------------
OBP 4.30.2.b 2009/06/16 07:02



System Configuration: Sun Microsystems sun4v SPARC Enterprise T5220
Memory size: 32640 Megabytes

================================ Virtual CPUs ================================


CPU ID Frequency Implementation Status
------ --------- ---------------------- -------
0 1165 MHz SUNW,UltraSPARC-T2 on-line
1 1165 MHz SUNW,UltraSPARC-T2 on-line
2 1165 MHz SUNW,UltraSPARC-T2 on-line
3 1165 MHz SUNW,UltraSPARC-T2 on-line
4 1165 MHz SUNW,UltraSPARC-T2 on-line
5 1165 MHz SUNW,UltraSPARC-T2 on-line
6 1165 MHz SUNW,UltraSPARC-T2 on-line
7 1165 MHz SUNW,UltraSPARC-T2 on-line
8 1165 MHz SUNW,UltraSPARC-T2 on-line
9 1165 MHz SUNW,UltraSPARC-T2 on-line
10 1165 MHz SUNW,UltraSPARC-T2 on-line
11 1165 MHz SUNW,UltraSPARC-T2 on-line
12 1165 MHz SUNW,UltraSPARC-T2 on-line
13 1165 MHz SUNW,UltraSPARC-T2 on-line
14 1165 MHz SUNW,UltraSPARC-T2 on-line
15 1165 MHz SUNW,UltraSPARC-T2 on-line
16 1165 MHz SUNW,UltraSPARC-T2 on-line
17 1165 MHz SUNW,UltraSPARC-T2 on-line
18 1165 MHz SUNW,UltraSPARC-T2 on-line
19 1165 MHz SUNW,UltraSPARC-T2 on-line
20 1165 MHz SUNW,UltraSPARC-T2 on-line
21 1165 MHz SUNW,UltraSPARC-T2 on-line
22 1165 MHz SUNW,UltraSPARC-T2 on-line
23 1165 MHz SUNW,UltraSPARC-T2 on-line
24 1165 MHz SUNW,UltraSPARC-T2 on-line
25 1165 MHz SUNW,UltraSPARC-T2 on-line
26 1165 MHz SUNW,UltraSPARC-T2 on-line
27 1165 MHz SUNW,UltraSPARC-T2 on-line
28 1165 MHz SUNW,UltraSPARC-T2 on-line
29 1165 MHz SUNW,UltraSPARC-T2 on-line
30 1165 MHz SUNW,UltraSPARC-T2 on-line
31 1165 MHz SUNW,UltraSPARC-T2 on-line

======================= Physical Memory Configuration ========================
Segment Table:
--------------------------------------------------------------
Base Segment Interleave Bank Contains
Address Size Factor Size Modules
--------------------------------------------------------------
0x0 32 GB 8 4 GB MB/CMP0/BR0/CH0/D0
MB/CMP0/BR0/CH1/D0
4 GB MB/CMP0/BR0/CH0/D1
MB/CMP0/BR0/CH1/D1
4 GB MB/CMP0/BR1/CH0/D0
MB/CMP0/BR1/CH1/D0
4 GB MB/CMP0/BR1/CH0/D1
MB/CMP0/BR1/CH1/D1
4 GB MB/CMP0/BR2/CH0/D0
MB/CMP0/BR2/CH1/D0
4 GB MB/CMP0/BR2/CH0/D1
MB/CMP0/BR2/CH1/D1
4 GB MB/CMP0/BR3/CH0/D0
MB/CMP0/BR3/CH1/D0
4 GB MB/CMP0/BR3/CH0/D1
MB/CMP0/BR3/CH1/D1


================================ IO Devices ================================
Slot + Bus Name + Model
Status Type Path
----------------------------------------------------------------------------
MB/NET0 PCIE network-pciex8086,105e
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0
MB/NET1 PCIE network-pciex8086,105e
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0,1
MB/NET2 PCIE network-pciex8086,105e
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0
MB/NET3 PCIE network-pciex8086,105e
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0,1
MB/SASHBA PCIE scsi-pciex1000,58 LSI,1068E
/pci@0/pci@0/pci@2/scsi@0
MB/RISER1/PCIE1 PCIX SUNW,emlxs-pci10df,fc20 LPe11000-S
/pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,emlxs@0
MB/RISER0/PCIE0 PCIX SUNW,emlxs-pci10df,fc20 LPe11000-S
/pci@0/pci@0/pci@8/pci@0/pci@9/SUNW,emlxs@0
MB PCIX usb-pciclass,0c0310
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0
MB PCIX usb-pciclass,0c0310
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,1
MB PCIX usb-pciclass,0c0320
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2

============================ Environmental Status ============================
Fan sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/FANBD0/FM0/F0 TACH ok
SYS/FANBD0/FM0/F1 TACH ok
SYS/FANBD0/FM1/F0 TACH ok
SYS/FANBD0/FM1/F1 TACH ok
SYS/FANBD0/FM2/F0 TACH ok
SYS/FANBD0/FM2/F1 TACH ok

Fan indicators:
------------------------------------------------------------
Location Sensor Condition
------------------------------------------------------------
SYS/PS0 FAN_FAULT ok
SYS/PS1 FAN_FAULT ok

Temperature sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/MB T_AMB ok
SYS/MB/CMP0/BR0/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR0/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR0/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR0/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR1/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR1/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR2/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR2/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR3/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR3/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH1/D1 T_AMB ok
SYS/MB/CMP0 T_TCORE ok
SYS/MB/CMP0 T_BCORE ok

Temperature indicators:
------------------------------------------------------------
Location Indicator Condition
------------------------------------------------------------
SYS/PS0 TEMP_FAULT ok
SYS/PS1 TEMP_FAULT ok

Current sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/PS0 I_IN_MAIN ok
SYS/PS0 I_IN_LIMIT ok
SYS/PS0 I_OUT_MAIN ok
SYS/PS0 I_OUT_LIMIT ok
SYS/PS1 I_IN_MAIN ok
SYS/PS1 I_IN_LIMIT ok
SYS/PS1 I_OUT_MAIN ok
SYS/PS1 I_OUT_LIMIT ok

Current indicators:
------------------------------------------------------------
Location Indicator Condition
------------------------------------------------------------
SYS/MB I_USB0 ok
SYS/MB I_USB1 ok
SYS/PS0 CUR_FAULT ok
SYS/PS1 CUR_FAULT ok

Voltage sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/MB V_VMEML ok
SYS/MB V_VMEMR ok
SYS/MB V_+3V3_STBY ok
SYS/MB V_VCORE ok
SYS/MB V_+3V3_MAIN ok
SYS/MB V_VDDIO ok
SYS/MB V_+12V0_MAIN ok
SYS/MB V_VBAT ok
SYS/PS0 V_IN_MAIN ok
SYS/PS0 V_OUT_MAIN ok
SYS/PS1 V_IN_MAIN ok
SYS/PS1 V_OUT_MAIN ok

Voltage indicators:
------------------------------------------------------------
Location Indicator Condition
------------------------------------------------------------
SYS/MB VCORE_POK ok
SYS/MB VMEML_POK ok
SYS/MB VMEMR_POK ok
SYS/PS0 AC_POK ok
SYS/PS0 DC_POK ok
SYS/PS0 VOLT_FAULT ok
SYS/PS1 AC_POK ok
SYS/PS1 DC_POK ok
SYS/PS1 VOLT_FAULT ok

LEDs:
------------------------------------------------------------
Location LED State
------------------------------------------------------------
SYS SERVICE off
SYS LOCATE off
SYS ACT steady
SYS PS_FAULT off
SYS TEMP_FAULT off
SYS FAN_FAULT off
SYS/MB/CMP0/BR0/CH0/D0 SERVICE off
SYS/MB/CMP0/BR0/CH0/D1 SERVICE off
SYS/MB/CMP0/BR0/CH1/D0 SERVICE off
SYS/MB/CMP0/BR0/CH1/D1 SERVICE off
SYS/MB/CMP0/BR1/CH0/D0 SERVICE off
SYS/MB/CMP0/BR1/CH0/D1 SERVICE off
SYS/MB/CMP0/BR1/CH1/D0 SERVICE off
SYS/MB/CMP0/BR1/CH1/D1 SERVICE off
SYS/MB/CMP0/BR2/CH0/D0 SERVICE off
SYS/MB/CMP0/BR2/CH0/D1 SERVICE off
SYS/MB/CMP0/BR2/CH1/D0 SERVICE off
SYS/MB/CMP0/BR2/CH1/D1 SERVICE off
SYS/MB/CMP0/BR3/CH0/D0 SERVICE off
SYS/MB/CMP0/BR3/CH0/D1 SERVICE off
SYS/MB/CMP0/BR3/CH1/D0 SERVICE off
SYS/MB/CMP0/BR3/CH1/D1 SERVICE off
SYS/HDD0 SERVICE off
SYS/HDD0 OK2RM off
SYS/HDD1 SERVICE off
SYS/HDD1 OK2RM off
SYS/HDD2 SERVICE off
SYS/HDD2 OK2RM off
SYS/HDD3 SERVICE off
SYS/HDD3 OK2RM off
SYS/HDD4 SERVICE off
SYS/HDD4 OK2RM off
SYS/HDD5 SERVICE off
SYS/HDD5 OK2RM off
SYS/HDD6 SERVICE off
SYS/HDD6 OK2RM off
SYS/HDD7 SERVICE off
SYS/HDD7 OK2RM off
SYS/FANBD0/FM0 SERVICE off
SYS/FANBD0/FM1 SERVICE off
SYS/FANBD0/FM2 SERVICE off

============================ FRU Status ============================
Location Name Status
------------------------------------------------------
SYS MB enabled
SYS/MB RISER0 enabled
SYS/MB RISER1 enabled
SYS/MB RISER2 enabled
SYS/MB SCC_NVRAM enabled
SYS/MB/CMP0/BR0/CH0 D0 enabled
SYS/MB/CMP0/BR0/CH0 D1 enabled
SYS/MB/CMP0/BR0/CH1 D0 enabled
SYS/MB/CMP0/BR0/CH1 D1 enabled
SYS/MB/CMP0/BR1/CH0 D0 enabled
SYS/MB/CMP0/BR1/CH0 D1 enabled
SYS/MB/CMP0/BR1/CH1 D0 enabled
SYS/MB/CMP0/BR1/CH1 D1 enabled
SYS/MB/CMP0/BR2/CH0 D0 enabled
SYS/MB/CMP0/BR2/CH0 D1 enabled
SYS/MB/CMP0/BR2/CH1 D0 enabled
SYS/MB/CMP0/BR2/CH1 D1 enabled
SYS/MB/CMP0/BR3/CH0 D0 enabled
SYS/MB/CMP0/BR3/CH0 D1 enabled
SYS/MB/CMP0/BR3/CH1 D0 enabled
SYS/MB/CMP0/BR3/CH1 D1 enabled
SYS HDD0 enabled
SYS HDD1 enabled
SYS HDD2 enabled
SYS HDD3 enabled
SYS HDD4 enabled
SYS HDD5 enabled
SYS HDD6 enabled
SYS HDD7 enabled
SYS PDB enabled
SYS PADCRD enabled
SYS SASBP enabled
SYS DVD enabled
SYS USBBD enabled
SYS FANBD0 enabled
SYS/FANBD0 FM0 enabled
SYS/FANBD0 FM1 enabled
SYS/FANBD0 FM2 enabled
SYS FANBD1 enabled
SYS PS0 enabled
SYS PS1 enabled

============================ FW Version ============================
Version
------------------------------------------------------------
Sun System Firmware 7.2.4.e 2009/09/21 09:50


====================== System PROM revisions =======================
Version
------------------------------------------------------------
OBP 4.30.4 2009/08/19 07:23

i have attached two machines prtdiag output, how to findout which is 8 core and 4 core processors
 

9 More Discussions You Might Find Interesting

1. Solaris

kstat on T5220

We used kstat on netra240/440 to check if the link is full duplex. So we do something like: bash-3.00# kstat -pc net bge:1::/'link_duplex'/ | cut -f2 2 The output 2 indicates the link is full duplex. This kind of check worked all right for Netra 240/440 systems. However, the nxge... (2 Replies)
Discussion started by: illcar
2 Replies

2. Solaris

ILOM and sc on T5220

I 've 2 different T5220 and both are showing different prompts when i ssh to the console. 1. Shows sc> ALOM 2. Shows -> ILOM as far as i know the T5220 comes with ILOM , so why i 'm seeing 2 different type of console for same tyep of hardware ? and i found that we... (6 Replies)
Discussion started by: fugitive
6 Replies

3. Solaris

SC on T5220 not responding

Hi, SC on one of my T5220 is not responding .. it does not show not let me type anything .. what could be the reason for it ? though when i powercycle the box from sc it shows me the system coming up but after that does not let me login thru sc sc> console -f Enter #. to return to ALOM. (2 Replies)
Discussion started by: fugitive
2 Replies

4. Solaris

LDOMs on T5220

We're just about to migrate a large application from an Enterprise 6900 to a pair of T5220s utilising LDOMs. Does anyone have any experience of LDOMs on this kit and can provide any recommendations or pitfalls to avoid? I've heard that use of LDOMs can have an impact on I/O speeds as it's all... (9 Replies)
Discussion started by: JerryHone
9 Replies

5. Solaris

T5220

Hi Guys and Gals, Wondering if anyone could help me, tricky one this. Got a T5220 with a graphics card. When you power it on, it outputs its output to the screen and you can type commands with the keyboard etc. But no matter what version of Solaris 10 you use, when you do a boot cdrom... (1 Reply)
Discussion started by: callmebob
1 Replies

6. Solaris

T5220

Hello guys, can anyone give me some advice on how to perform clean installation of Solaris 10 on T5220 ? I am connected with serial management port on the machine, i have the ok promt and now i should eject the dvdrom to insert Solaris dvd into and start the clean install. So how to do that... (3 Replies)
Discussion started by: tonijel
3 Replies

7. Solaris

Test program running taking much more time on high end server T5440 than low end server T5220

Hi all, I have written the following program and run on both T5440 and T5220 on same OS version. I found that T5540 server takes more time than T5220. Please find below the details. test1.cpp #include <iostream> #include <pthread.h> using namespace std; #define NUM_OF_THREADS 20... (17 Replies)
Discussion started by: sanjay_singh85
17 Replies

8. Solaris

Where are my other disks on T5220 ?

Hi, I got a (used) server to install Solaris 11 and wipe out every information on existing disks. There are 6 disks of 300GB and two disks of 146GB. I am not able to figure out, how to find out RAID (if there is any) and break it. Can anybody help me with that ? Below is configuration. I have... (18 Replies)
Discussion started by: solaris_1977
18 Replies

9. Solaris

I can't boot my Sun T5220 server from cdrom.

hi:) i can't boot my sun server by iso solaris 10 sparc dvd that i did download from oracle site. my hardware is sun T5220. i receive these after running boot cdrom -s : can't read disk lable can't open disk lable package ERROR: boot-read fail whould u help me? Please use CODE... (1 Reply)
Discussion started by: Arefdel
1 Replies
All times are GMT -4. The time now is 06:19 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy