Sponsored Content
Full Discussion: Configure EMC Powerpath?
Operating Systems Linux Red Hat Configure EMC Powerpath? Post 302375862 by Scrutinizer on Monday 30th of November 2009 01:10:39 AM
Old 11-30-2009
There should be a /etc/modprobe.conf.pp and a reference to it in modprobe.conf. If they are there, perhaps your SAN drivers do not get loaded at boot time and the mkinitrd did not go right? What do the logs say?

Last edited by Scrutinizer; 11-30-2009 at 02:19 AM..
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Can Veritas DMP & EMC PowerPath coexist?

We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist? Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
Discussion started by: aaron2k
2 Replies

2. Solaris

change SP value in powerpath

How to change the following values in power path from SP B to SP A ? Owner: default=SP B, current=SP B this is excerpt from powermt display dev=all (3 Replies)
Discussion started by: fugitive
3 Replies

3. AIX

Cannot uninstall powerpath - bosboot issues

Hi Guys, I have a problem while trying to upgrade to more current EMC powerpath software on AIX 5.3 - respectively uninstalling the existing one. I tried to deinstall the powerpath software with removed disks - was working perfectly fine on 12 servers - but number 13 is failing with errors: ... (4 Replies)
Discussion started by: zxmaus
4 Replies

4. Solaris

Solaris 10 with Veritas and PowerPath

Hello, I have an issue with veritas volume manager version 5.0 in combination with EMC powerpath version 5.2.0 running on Solaris10(Sparc). This server is fiber connected to a EMC Clariion CX3-40 SAN. This is the situation : Server is a SUN Enterprise M5000 OS = Solaris10 Sparc Veritas... (1 Reply)
Discussion started by: chipke2005
1 Replies

5. Solaris

Migrate from MPXIO to Powerpath

Here is the issue: I am building a database server using Solaris 10x86 U8. The system is jumpstarted with mpxio enabled and booting from the san. We need to have powerpath 5.3 installed and would like to have powerpath take control of the the boot san as well or have mpxio control the san... (2 Replies)
Discussion started by: nabru72
2 Replies

6. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

7. Linux

EMC, PowerPath and issue on using LUN

Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3. I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process: echo "1" > /sys/class/fc_host/host<n>/issue_lip and echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies

8. Solaris

Powerpath upgrade with SVM disksets

Hi all I am running the following hardware: 2 SUN Solaris 10 machines They are connected to EMC clarion LUNs We are running a Sun Cluster 3.2 managing both nodes We are using Solaris Volume Manager to handle the shared storage for the cluster. It is using a number of named disk sets that is... (0 Replies)
Discussion started by: abohmeed
0 Replies

9. Solaris

One emc powerpath failed

It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Discussion started by: solaris_1977
0 Replies

10. Solaris

Emc powerpath device & zfs query

Hi, We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs. The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Discussion started by: badoshi
7 Replies
NVD(4)							   BSD Kernel Interfaces Manual 						    NVD(4)

NAME
nvd -- NVM Express disk driver SYNOPSIS
To compile this driver into your kernel, place the following lines in your kernel configuration file: device nvme device nvd Or, to load the driver as a module at boot, place the following lines in loader.conf(5): nvme_load="YES" nvd_load="YES" DESCRIPTION
The nvd driver exposes NVM Express (NVMe) namespaces as disks to the kernel disk storage API. It depends on the nvme(4) driver for notifica- tion of existing NVMe namespaces and submission of NVM I/O commands. Device nodes from the nvd driver will have the format /dev/nvdX and are GEOM(4) disks which can be partitioned by geom(8). Note that device nodes from the nvme(4) driver are not GEOM(4) disks and cannot be partitioned. SEE ALSO
GEOM(4), nvme(4), geom(8), nvmecontrol(8), disk(9) HISTORY
The nvd driver first appeared in FreeBSD 9.2. AUTHORS
The nvd driver was developed by Intel and originally written by Jim Harris <jimharris@FreeBSD.org>, with contributions from Joe Golio at EMC. This man page was written by Jim Harris <jimharris@FreeBSD.org>. BSD
March 18, 2014 BSD