Sponsored Content
Full Discussion: Configure EMC Powerpath?
Operating Systems Linux Red Hat Configure EMC Powerpath? Post 302375851 by Makri on Sunday 29th of November 2009 11:24:38 PM
Old 11-30-2009
No I dont have any documentation. Can you please help me with this.??
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Can Veritas DMP & EMC PowerPath coexist?

We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist? Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
Discussion started by: aaron2k
2 Replies

2. Solaris

change SP value in powerpath

How to change the following values in power path from SP B to SP A ? Owner: default=SP B, current=SP B this is excerpt from powermt display dev=all (3 Replies)
Discussion started by: fugitive
3 Replies

3. AIX

Cannot uninstall powerpath - bosboot issues

Hi Guys, I have a problem while trying to upgrade to more current EMC powerpath software on AIX 5.3 - respectively uninstalling the existing one. I tried to deinstall the powerpath software with removed disks - was working perfectly fine on 12 servers - but number 13 is failing with errors: ... (4 Replies)
Discussion started by: zxmaus
4 Replies

4. Solaris

Solaris 10 with Veritas and PowerPath

Hello, I have an issue with veritas volume manager version 5.0 in combination with EMC powerpath version 5.2.0 running on Solaris10(Sparc). This server is fiber connected to a EMC Clariion CX3-40 SAN. This is the situation : Server is a SUN Enterprise M5000 OS = Solaris10 Sparc Veritas... (1 Reply)
Discussion started by: chipke2005
1 Replies

5. Solaris

Migrate from MPXIO to Powerpath

Here is the issue: I am building a database server using Solaris 10x86 U8. The system is jumpstarted with mpxio enabled and booting from the san. We need to have powerpath 5.3 installed and would like to have powerpath take control of the the boot san as well or have mpxio control the san... (2 Replies)
Discussion started by: nabru72
2 Replies

6. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

7. Linux

EMC, PowerPath and issue on using LUN

Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3. I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process: echo "1" > /sys/class/fc_host/host<n>/issue_lip and echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies

8. Solaris

Powerpath upgrade with SVM disksets

Hi all I am running the following hardware: 2 SUN Solaris 10 machines They are connected to EMC clarion LUNs We are running a Sun Cluster 3.2 managing both nodes We are using Solaris Volume Manager to handle the shared storage for the cluster. It is using a number of named disk sets that is... (0 Replies)
Discussion started by: abohmeed
0 Replies

9. Solaris

One emc powerpath failed

It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Discussion started by: solaris_1977
0 Replies

10. Solaris

Emc powerpath device & zfs query

Hi, We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs. The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Discussion started by: badoshi
7 Replies
norewind_close_disabled(5)					File Formats Manual					norewind_close_disabled(5)

NAME
norewind_close_disabled - determine whether access to tape device special files without the no-rewind-on-close option is allowed VALUES
Default Allowed values DESCRIPTION
Note: this tunable was named in releases prior to HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on, the tape driver will fail any open on a tape device special file that does not have the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued accidentally from this system on close, possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. EXAMPLES
Query the current value of the tunable: Set the value of the tunable to To save the value of the tunable across reboots: WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters norewind_close_disabled(5)
All times are GMT -4. The time now is 07:14 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy