Hi ,
I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and then I can get into system.

1.How do I start up emc powerpath driver automatically... ?

I did lsmod and restart the service.. still it gives the same problem...

I thought of uninstall and reinstalling the emc powerpath and reconfigure the whole thing... is that good idea???

If so, How do i configure the EMC Powerpath?
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Can Veritas DMP & EMC PowerPath coexist?

We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist? Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
Discussion started by: aaron2k
2 Replies

2. Solaris

change SP value in powerpath

How to change the following values in power path from SP B to SP A ? Owner: default=SP B, current=SP B this is excerpt from powermt display dev=all (3 Replies)
Discussion started by: fugitive
3 Replies

3. AIX

Cannot uninstall powerpath - bosboot issues

Hi Guys, I have a problem while trying to upgrade to more current EMC powerpath software on AIX 5.3 - respectively uninstalling the existing one. I tried to deinstall the powerpath software with removed disks - was working perfectly fine on 12 servers - but number 13 is failing with errors: ... (4 Replies)
Discussion started by: zxmaus
4 Replies

4. Solaris

Solaris 10 with Veritas and PowerPath

Hello, I have an issue with veritas volume manager version 5.0 in combination with EMC powerpath version 5.2.0 running on Solaris10(Sparc). This server is fiber connected to a EMC Clariion CX3-40 SAN. This is the situation : Server is a SUN Enterprise M5000 OS = Solaris10 Sparc Veritas... (1 Reply)
Discussion started by: chipke2005
1 Replies

5. Solaris

Migrate from MPXIO to Powerpath

Here is the issue: I am building a database server using Solaris 10x86 U8. The system is jumpstarted with mpxio enabled and booting from the san. We need to have powerpath 5.3 installed and would like to have powerpath take control of the the boot san as well or have mpxio control the san... (2 Replies)
Discussion started by: nabru72
2 Replies

6. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

7. Linux

EMC, PowerPath and issue on using LUN

Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3. I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process: echo "1" > /sys/class/fc_host/host<n>/issue_lip and echo "- - -" >... (10 Replies)
Discussion started by: Zarnick
10 Replies

8. Solaris

Powerpath upgrade with SVM disksets

Hi all I am running the following hardware: 2 SUN Solaris 10 machines They are connected to EMC clarion LUNs We are running a Sun Cluster 3.2 managing both nodes We are using Solaris Volume Manager to handle the shared storage for the cluster. It is using a number of named disk sets that is... (0 Replies)
Discussion started by: abohmeed
0 Replies

9. Solaris

One emc powerpath failed

It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Discussion started by: solaris_1977
0 Replies

10. Solaris

Emc powerpath device & zfs query

Hi, We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs. The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Discussion started by: badoshi
7 Replies
IPX_CMD(8)						      System Manager's Manual							IPX_CMD(8)

NAME
ipx_cmd - bridge between Novell's SCMD driver and local IPX network SYNOPSIS
ipx_cmd -A server name [ -l local interface name ] DESCRIPTION
ipx_cmd moves packets from tapN to server and vice versa. It is something like IPX Tunnel, but it uses Novell Netware 5 server Compatibil- ity Mode Driver (AKA Migration Agent) on the other end of wire. You must first configure your kernel tapN device with IPX EthernetII frame and with network number set up on server (you can use kernel autodetection). OPTIONS
-A server name This is IP name of compatibility mode server. You can use DNS name or dotted quad to specify server address. -l local interface name This allows you to specify, which of your IP addresses should be used as IP address of client side of CMD driver. You must configure your tapN device with hardware address 7E:01:AA:BB:CC:DD, where AA:BB:CC:DD is your IP address in hexa. EXAMPLE
If you are on server platan.vc.cvut.cz (147.32.240.81) and your migration agent runs on server boris.vc.cvut.cz, you can configure your system with: insmod ethertap ifconfig tap0 hw ether 7E:01:93:20:F0:51 up ipx_interface add -p tap0 EtherII ipx_cmd -A boris.vc.cvut.cz -l 147.32.240.81 & BUGS
This program was written to satisfy my own needs and should be really improved. At least it should configure tap interface itself. AUTHOR
Petr Vandrovec <vandrove@vc.cvut.cz> ipx_cmd IPX Utilities IPX_CMD(8)
All times are GMT -4. The time now is 06:28 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy