Question Warning HD: no root disk controller was found

hi...
i hav a problem to install sco unix
while installing sco unix 5.0.5 in acer altos with hardware raid
am getting error

"Warning HD: no root disk controller was found
system error 5: while getting fs type
flushing controller: DAC960PRL cache done."

i hav use the following commands
boot: defbootstr link=mdac
boot: ahslink
boot: defbootstr ahslink=mdac Sdsk=mdac(0,0,0,1)
boot: defbootstr ahslink=mdac Sdsk=mdac(0,0,1)
but these command are not working.....

plz help me.. i want to solve the problem with in 2days..
 

10 More Discussions You Might Find Interesting

1. Solaris

Controller target disk?

Hi, I am a newbie to Solaris. I want to know how to find out the controller target and disk number on a SunFire V890 box that has 6X72GB disks. The probe-scsi output is as shown below: /pci@8,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 ... (1 Reply)
Discussion started by: sudhir_shet
1 Replies

2. SCO

warning:hd:no root disk controler was found

hi all i use sco open server reliseas 5 on my system i get an image from system hard disk to another hard disk with acronis software and start system with new(backup)hard disk, but during the boot process some errors generate as follow warning:hd:noroot disk controler was found hd:a boot-time... (2 Replies)
Discussion started by: mehran_malek
2 Replies

3. HP-UX

[Joy Share] - Replace an unknown status controller on HP FC60 disk array

Replace an unknown status controller on HP FC60 disk array Author:JoyOnline JoyChangLu@gmail.com Trouble description: The users detected that the status of controller at A is unknown. Analysis and diagnostic: Physical observed all leds on enclosure of disk array is normal. The... (4 Replies)
Discussion started by: JoyOnLine
4 Replies

4. SCO

SCO 5.0.7 no root disk controller found error during install

I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd. I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies

5. Solaris

Help needed to find out the disk controller for veritas disks

hi all i am using vxvm 5.1 on my sun blade 150 which is running with solaris 5.10. When i give the command "vxdisk list" it gives the following output # vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online... (2 Replies)
Discussion started by: kingston
2 Replies

6. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

7. Solaris

Changed disk controller -> drops into GRUB?!

I changed disk controller. Unplugged every disk, inserted another controller card, an IBM M1015. The disks are recognized in BIOS, and the controller card's BIOS shows up. But after that, I drop into GRUB and a prompt. That is all. How shall I solve this problem? I am thinking of booting from... (2 Replies)
Discussion started by: kebabbert
2 Replies

8. Solaris

Lost Root Password on VXVM Encapsulated Root Disk

Hi All Hope it's okay to post on this sub-forum, couldn't find a better place I've got a 480R running solaris 8 with veritas volume manager managing all filesystems, including an encapsulated root disk (I believe the root disk is encapsulated as one of the root mirror disks has an entry under... (1 Reply)
Discussion started by: sunnyd76
1 Replies

9. Solaris

Disk controller reassignment

Hi The scenario in the oracle t4-1 hardware with solaris 10 is as follows: 1. The initial install on the server was performed with an incorrect disk layout. 2. New disks were ordered and slot into the server. 3. The disks are allocated a controller and a disk number based on the disk or... (13 Replies)
Discussion started by: kerrygold
13 Replies

10. Solaris

Sun Fire v440 Hard disk or controller broken? WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1)

Hi, I have a Sun Fire V440 server that fails to boot up correctly. A lot of services are not started and the sytems acts really slow to commands. During boot I can see the following Error: WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1): SCSI transport failed: reason 'reset': retrying... (15 Replies)
Discussion started by: oliwei
15 Replies
GEODEIDE(4)						   BSD Kernel Interfaces Manual 					       GEODEIDE(4)

NAME
geodeide -- AMD Geode IDE disk controllers driver SYNOPSIS
geodeide* at pci? dev ? function ? flags 0x0000 DESCRIPTION
The geodeide driver supports the AMD Geode CS5530A and SC1100 IDE controllers, and provides the interface with the hardware for the ata(4) driver. The 0x0002 flag forces the geodeide driver to disable DMA on chipsets for which DMA would normally be enabled. This can be used as a debug- ging aid, or to work around problems where the IDE controller is wired up to the system incorrectly. SEE ALSO
ata(4), atapi(4), intro(4), pci(4), pciide(4), wd(4), wdc(4) BUGS
The SC1100 controller requires 4-byte aligned data transfers and cannot handle transfers of exactly 64 kilobytes. The CS5530 multifunction chip/core's IDE section claims to be capable of UDMA mode 2 (33.3MB/s) but in practice using that mode swamps the controller so badly that geodeide limits the UDMA negotiation to mode 1 (25MB/s) so that the other functions of this chip continue to work. The IDE DMA engine in the CS5530 can only do transfers on cache-line (16-byte) boundaries. Attempts to perform DMA on any other alignment will crash the system. This problem may also exist in the SC1100 since the CS5530 was its direct predecessor, and it is not clear that National Semiconductor fixed any bugs in it. The geodeide driver will reject attempts to DMA to buffers not aligned to the required boundary. The wd(4) disk driver will back off to PIO mode to accomplish these transfer requests, at reduced system performance. BSD
July 5, 2005 BSD
All times are GMT -4. The time now is 12:46 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy