Sponsored Content
Full Discussion: POWER6 VIO Failover
Operating Systems AIX POWER6 VIO Failover Post 302315070 by homeyjoe on Monday 11th of May 2009 11:40:59 AM
Old 05-11-2009
As far as I know there isn't any automatic load balancing you can do. Normally you will present hdisk from each VIO like you've done and then you would mirror it.

So if LPAR1 has hdisk0 from VIO1, and hdisk1 from VIO2, then when you mirror hdisk0 to hdisk1 you would be covered if you have to reboot VIO1 or VIO2.
 

9 More Discussions You Might Find Interesting

1. AIX

Oracle 10G best practices on Power6 AIX5.3

Can anyone point me to any best practices for partitioning, resource prerequisites, and implementation of Oracle 10G release 2 with RAC on 2 power6 550's running AIX5.3 as a cluster? (1 Reply)
Discussion started by: JodyTek
1 Replies

2. AIX

Power6 Virtual Fibre Channel Adapter

Hello, Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter. It is similar to virtual scsi adapter. In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Discussion started by: filosophizer
1 Replies

3. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

4. AIX

AIX 6.1 Power6 - Sys CPU utilization twice that of User

Hello, We just purchased two new 4-way (one active one failover) 5Ghz Power6 Servers (failover) with 64GB RAM (32GB per node) runing AIX 6.1 with two LPARs per node connected to our SAN with two 4GB HBAs. The PROD LPAR has 2 dedicated CPUs (4 virtual) and the TEST LPAR has 2 dedicated CPUs. ... (3 Replies)
Discussion started by: troym72
3 Replies

5. AIX

HACMP with VIO, service IP failover

Would anyone please kindly help to solve this problem... An LPAR with the below network configuration. ent0 and ent1 are logical lan (virtual ethernet) from VIO SEA. en0 1.2.3.4 <- boot ip 192.168.1.1 <- persistent ip 192.168.1.10 <- service ip en1 11.22.33.44 <- boot ip When I... (6 Replies)
Discussion started by: skeyeung
6 Replies

6. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

7. AIX

Power6 vs. Power7 hardware performance

I know I will get blasted for posting here, not know where to post this, however, I have performance question between the 2 platforms. Not knowing the exact processors in each box, but the Power6 Platform clock speed is 4400 (?? at least what was told to me), and the Power7 clock speed is 3500.... (5 Replies)
Discussion started by: mrmurdock
5 Replies

8. AIX

How to get power6 power FRU?

how to get power6 power FRU? the power5 can get by this command: lscfg -vp | grep -p 'AC PS' | grep FRU however, the power6 machine cannot get any info for that command. thanks (1 Reply)
Discussion started by: rainbow_bean
1 Replies

9. AIX

Hard drive compatibility for POWER6 p520

Hi, I have recently inherited an old p520 from work running AIX 6.1, based on the POWER6 CPU. I'm planning to play around with it and use it to learn the system, so this is a purely personal project. The machine is not under a support contract any more. I am looking to replace one of the disks... (11 Replies)
Discussion started by: topcat
11 Replies
roar_vs_connection_obj(3)				   RoarAudio Programmer's Manual				 roar_vs_connection_obj(3)

NAME
roar_vs_connection_obj, roar_vs_stream_obj, roar_vs_vio_obj - VS API interface for use of main API SYNOPSIS
#include <roaraudio.h> struct roar_connection * roar_vs_connection_obj(roar_vs_t * vss, int * error); struct roar_stream * roar_vs_stream_obj (roar_vs_t * vss, int * error); struct roar_vio_calls * roar_vs_vio_obj (roar_vs_t * vss, int * error); DESCRIPTION
Those functions return internal connection, stream and VIO object of the VS object. They are used to use the main API with a VS opened stream. roar_vs_connection_obj() returns the connection object used for the control connection to the server. roar_vs_stream_obj() returns the stream object storing information about the stream. roar_vs_vio_obj() returns the VIO object used to read data from or send data to the server. Returned objects are freed as soon as the VS object is closed. If the VS object was created using roar_vs_new_from_con(3) the connection is not closed by the VS object and stay valid after close until it is closed by the program or library. The VIO object MUST NOT be used while in buffered mode. PARAMETERS
vss The VS object to return internal objects from. error This is a pointer to a integer used to store the error value in case of error. This can be NULL if not used but it is very recom- mended to use this error value to report good error messages to the user. RETURN VALUE
On success these calls return the described object. On error, NULL is returned. EXAMPLES
FIXME SEE ALSO
roarvs(7), libroar(7), RoarAudio(7). RoarAudio May 2011 roar_vs_connection_obj(3)
All times are GMT -4. The time now is 08:01 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy