Sponsored Content
Full Discussion: SAN Configuration in Solaris
Top Forums UNIX for Advanced & Expert Users SAN Configuration in Solaris Post 302108770 by Remi on Wednesday 28th of February 2007 10:57:10 PM
Old 02-28-2007
SAN Configuration in Solaris

Reborg,

I don't think so. I have on server with Solaris SAN that I configured on the same SAN that works fine, the only difference is the HBA card on that on is Qlogic QLA card versus the SUN qlc cards that I'm having problems with.


Remi
 

9 More Discussions You Might Find Interesting

1. Solaris

SAN Configuration in Solaris

I Have IBM ESS 800, trying to configure SAN storage using Fiber card. I installed the SDD driver & can see the disks however, when I did # datapath query device I have the disks shown in slices # ./datapath query device Total Devices : 8 Dev#: 0 Device Name: vpath1a Type:... (0 Replies)
Discussion started by: Remi
0 Replies

2. AIX

AIX SAN configuration problems/oddity

Hi, I have a strange problem. we're trying to connect an IBM pseries, to a Brocade switch, for SAN acess, using a badged emulex card, (IBM FC6239) WE can configure the device to see the fabric. The only problem we have is that the Brocade sees the HBA as storage, and not as a HBA. We've zoned... (1 Reply)
Discussion started by: praxis22
1 Replies

3. Solaris

Solaris and SAN

Hi, How can we differentiate a SAN disk with a Solaris local disk? Please respond. Thanks (4 Replies)
Discussion started by: balu_solaris
4 Replies

4. Solaris

need help for removing SAN LUNS on solaris 9

Hi I would like to remove SAN luns from system and do not want them even after system reboot, format Searching for disks...done df -kh I know last 4 partitions are from SAN but there could be more. Can someone please help me correct steps to remove SAN Luns. vxdisk list ... (2 Replies)
Discussion started by: upengan78
2 Replies

5. Solaris

SAN Storage to solaris 10 server

Hi, I have configured our SAN Storage to be connected to our new SUN T5220. On the SAn it looks all fine on the server I do not see any connection: cfgadm -al Ap_Id Type Receptacle Occupant Condition c1 scsi-bus connected ... (4 Replies)
Discussion started by: manni2
4 Replies

6. Solaris

Solaris in a SAN BOOT

My current situation is like this, I have a v440 connected to a netapp central storage 3140 via fiber channel, my OS and oracle is installed in the internal drive of the v440. What I would like to do is to advertise another LUN in netapp to the v440 and let my v440 boot from it so I can start... (3 Replies)
Discussion started by: q8devilish
3 Replies

7. Solaris

SAN boot solaris 10

I have a solaris 10 box which does not have internal disks it has just a single dual port HBA card. Storage team has assigned 2 LUNs to the system and i can see it from the probe-scsi-all /pci@3,700000/SUNW,emlxs@0,1 Device PortID 10100 WWPN 5006016941e0a08d LUN 0 Disk DGC ... (0 Replies)
Discussion started by: fugitive
0 Replies

8. Solaris

Solaris SAN configuration.

HI All, What are IPFC(Internet Protocol over Fibre channel) SAN devices. What all i got from guide is "Configuring IPFC over host system describes host recognition of IPFC devices and implementation of IP over FC in SAN" What does above statement actually mean. I would appreciate detailed... (2 Replies)
Discussion started by: ravijanjanam12
2 Replies

9. Solaris

Moving Solaris 9 Host to new SAN.

Hi All, Hopefully you can answer my question. We are about to move to a new Fibre Channel infrastructure going from Cisco to Brocade switches. Amongst others, we have a number of Solaris 9 hosts which connect to our EVA5000 and EVA8100 array's. What is involved in moving the Solaris hosts to... (3 Replies)
Discussion started by: eptc
3 Replies
st_san_safe(5)							     OBSOLETED							    st_san_safe(5)

NAME
st_san_safe - determine whether access to tape device special files without the no-rewind-on-close option is allowed (OBSOLETED) VALUES
Failsafe Default Allowed values Recommended values or DESCRIPTION
Note: this tunable is obsoleted and has been renamed to beginning with release HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on the tape driver will fail any open on a tape device special file without the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued from this system accidentally on close possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
norewind_close_disabled(5), scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters st_san_safe(5)
All times are GMT -4. The time now is 10:16 AM.