06-06-2006
check logs for temp?
I'm fairly new to hpux, so this is what i've been trying to figure out. Is it possible to get any logs on hpux that would indicate if the system, cpu, or other hardware components reached above normal or critical temperatures?
Thanks,
-K
Last edited by uzerx; 06-06-2006 at 03:11 PM..
9 More Discussions You Might Find Interesting
1. SCO
Is there command in sco unixware 7.1.3 from which i can find the temperature of the system/hardware.
Something equivalent to prtdiag in solaris maybe
thanks (1 Reply)
Discussion started by: gsb81
1 Replies
2. Solaris
Hi all
I have a SUN V480 server with 4 processores and I've noticed that the temperature for 2 of the 4 processers are quite high (63 degrees Celsius).
Does anyone know what the operating temperatures of the Sparc CPU's are? I'm not getting any warning messages yet, but I want to resolve the... (3 Replies)
Discussion started by: soliberus
3 Replies
3. Solaris
How to get a CPU temperature and current power consumption in T5220 server both from system controller and Operating system. I need details by cores. Thanks in advance. (13 Replies)
Discussion started by: fugitive
13 Replies
4. UNIX for Dummies Questions & Answers
People hello to everybody exist a way to do a script for view the temperature. I have
Red Hat Linux release 9 (Shrike)
Kernel 2.4.20-8 on an i686
THANk YOU FOR YOUR TIME. (4 Replies)
Discussion started by: enkei17
4 Replies
5. Solaris
Hello all,
I am using prtdiag -v command to find the temperature sensors . And i dont see the following o/p .
ystem Configuration: Hewlett-Packard HP Z400 Workstation
BIOS Configuration: Hewlett-Packard 786G3 v01.17 08/19/2009
==== Processor Sockets ====================================
... (2 Replies)
Discussion started by: b.preeya22
2 Replies
6. Solaris
some say '/usr/sfw/bin/ipmitool' can be used to read temperature. has anyone tried it? what options should be used? (1 Reply)
Discussion started by: orange47
1 Replies
7. Shell Programming and Scripting
Hello,
I am trying to work on a temperature script to check temperatures on my systems. Im trying to get the basics laid out first. So far i have a command:
/usr/sbin/prtpicl -v -c temperature-sensor # (must run as root)
This command kicks back alot of information but i only want the... (3 Replies)
Discussion started by: whotippedmycow
3 Replies
8. Hardware
What is the max operating temperature for 'UltraSPARC IIIi 1 GHz' ?
thanks. (1 Reply)
Discussion started by: orange47
1 Replies
9. Shell Programming and Scripting
i have this script which result is cpu temp in celsius
first install:
apt-get install lm-sensors
YES |sensors-detect --auto
#!/bin/bash
# 1. get temperature
## a. split response
## Core 0: +143.6°F (high = +186.8°F, crit = +212.0°F)
IFS=')' read -ra core_temp_arr <<<... (11 Replies)
Discussion started by: tomislav91
11 Replies
boot(1M) boot(1M)
NAME
boot - bootstrap process
DESCRIPTION
Itanium-based System Hardware
An system's bootstrap process involves the execution of four software components:
o CMOS
o option ROM
o EFI
o Boot Manager
o (see hpux.efi(1M)).
After the processor is reset, firmware initializes and tests processors and platform. During initialization, the firmware lets a user
interrupt and configure CMOS and option ROMs. It then transfers control to EFI, the Extensible Firmware Interface. EFI, in turn, initial-
izes EFI boot and runtime services and launches the Boot Manager. The Boot Manager, which allows loading of EFI application or drivers
from EFI defined file system, loads and transfers control to the HP-UX-specific bootstrap loader. then loads the HP-UX kernel object file
from the HP-UX file system to memory and transfers control to the loaded kernel image.
PA-RISC Hardware
The PA-RSIC bootstrap process involves the execution of three software components:
o (see pdc(1M),
o (see isl(1M), and
o (see hpux(1M).
After the processor is RESET, the (firmware), performs a self-test and initializes the processor. It then loads and transfers control to
the operating-system-independent in turn, loads and transfers control to the utility, the HP-UX-specific bootstrap loader. then downloads
the HP-UX kernel object file from an HP-UX file system and transfers control to the loaded kernel image.
SEE ALSO
hpux(1M), hpux.efi(1M), isl(1M), pdc(1M), efi(4).
boot(1M)