02-26-2006
you could have a look in your prtdiag(M) output or prtconf(M) or swap(M)
gP
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hello,
I need explanations about physical disks and physical volumes. What is the difference between these 2 things?
In fact, i am trying to understand what the AIX lspv2command does.
Thank you in advance. (2 Replies)
Discussion started by: VeroL
2 Replies
2. UNIX for Dummies Questions & Answers
I was in smit, checking on disc space, etc. and it appears that one of our physical volumes that is part of a large volume group, has no free physical partitions. The server is running AIX 5.1. What would be the advisable step to take in this instance? (9 Replies)
Discussion started by: markper
9 Replies
3. Solaris
Hi All,
I am trying to find the physical memory usage by each process/users.
Can you please let me know how to get the memory usage?.
Thanks,
bsraj. (12 Replies)
Discussion started by: bsrajirs
12 Replies
4. Red Hat
Hi,
On server 64bit Hw Arch , Linux 5.0(32bit) is installed it is showing only 3gb of ram though physical is 16gb
can u give me idea why? (4 Replies)
Discussion started by: manoj.solaris
4 Replies
5. AIX
Hello All,
Can anybody please tell me what is the maximum limit of Physical IBM Power Machine which can be handled by single HMC at a single point of time?
Thanks,
Jenish (1 Reply)
Discussion started by: jenish_shah
1 Replies
6. Solaris
I have a Sun T5120, and I want to programmatically determine how much RAM it has.
# uname -a
SunOS myhost 5.10 Generic_141444-09 sun4v sparc SUNW,SPARC-Enterprise-T5120
The box has 64Gb; I tried prtdiag and prtconf, but they give me bogus info
prtconf gives me:
# prtconf |grep -i... (12 Replies)
Discussion started by: thomn8r
12 Replies
7. Solaris
After a memory upgrade all network interfaces are misconfigued. How do i resolve this issue. Below are some out puts.thanks.
ifconfig: plumb: SIOCLIFADDIF: eg000g0:2: no such interface
# ifconfig eg1000g0:2 plumb
ifconfig: plumb: SIOCLIFADDIF: eg1000g0:2: no such interface
# ifconfig... (2 Replies)
Discussion started by: andersonedouard
2 Replies
8. Red Hat
Hi,
I have a server (BL460c) with 32G of physical RAM.
It currently only uses approx 5% its capacity but will use more (not sure how much more) pending the launch of further applications.
If I need to build another node of similar functionality should I consider downgrading the physical... (2 Replies)
Discussion started by: Duffs22
2 Replies
9. UNIX for Dummies Questions & Answers
Hi,
I am new to unix. I am working on Red Hat Linux and side by side on AIX also. After reading the concepts of Storage, I am now really confused regarding the terminologies
1)Physical Volume
2)Volume Group
3)Logical Volume
4)Physical Partition
Please help me to understand these concepts. (6 Replies)
Discussion started by: kashifsd17
6 Replies
10. Solaris
Hi,
kstat -p -m zfs -n arcstats -s size returns
zfs:0:arcstats:size 8177310584
this values is approx (7.61 GB)
but my Physical Memory size is only 6144 Megabytes.
Can this happen ?
if yes, then how can I find free memory on the system.
BTW, I ran the kstat commands from a Non... (2 Replies)
Discussion started by: sapre_amit
2 Replies
prtdiag(1M) prtdiag(1M)
NAME
prtdiag - display system diagnostic information
SYNOPSIS
/usr/sbin/prtdiag [-v] [-l]
prtdiag displays system configuration and diagnostic information on sun4u and sun4v systems.
The diagnostic information lists any failed field replaceable units (FRUs) in the system.
The interface, output, and location in the directory hierarchy for prtdiag are uncommitted and subject to change in future releases.
prtdiag does not display diagnostic information and environmental status when executed on the Sun Enterprise 10000 server. See the
/var/opt/SUNWssp/adm/${SUNW_HOSTNAME}/messages file on the system service processor (SSP) to obtain such information for this server.
The following options are supported:
-l Log output. If failures or errors exist in the system, output this information to syslogd(1M) only.
-v Verbose mode. Displays the time of the most recent AC Power failure, and the most recent hardware fatal error information, and (if
applicable) environmental status. The hardware fatal error information is useful to repair and manufacturing for detailed diagnos-
tics of FRUs.
The following exit values are returned:
0 No failures or errors are detected in the system.
1 Failures or errors are detected in the system.
2 An internal prtdiag error occurred, for example, out of memory.
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SUNWkvm |
+-----------------------------+-----------------------------+
|Interface Stability |Unstable* |
+-----------------------------+-----------------------------+
*The output is unstable.
modinfo(1M), prtconf(1M), psrinfo(1M), sysdef(1M), syslogd(1M), attributes(5), openprom(7D)
NOTES
Not all diagnostic and system information is available on every Solaris platforn, and therefore cannot be displayed by prtdiag. On those
platforms, further information can be obtained from the System Controller.